Two-dimensional speckle-tracking echocardiography (2D-STE) is an advanced imaging technique that offers quantitative insights into myocardial function by analyzing the motion of speckles created during ultrasound–tissue interactions. This study aims to evaluate the reliability of 2D-STE by examining the impact of key technical parameters on global longitudinal strain (GLS) measurement accuracy and comparing two speckle-tracking analysis methods provided by GE Healthcare: quantitative analysis of the 2D strain (2D strain) and automated function imaging (AFI). The prospective study consisted of two cohorts. In the first cohort, including 16 healthy dogs, the influence of frame rate, heart rate variation, zoom, transducer frequency, and image foreshortening on speckle-tracking values was assessed. In the second cohort, which included 10 healthy dogs, 2D-STE parameters were obtained with the 2D strain and AFI to assess agreement between the methods and observer variability. Our findings indicate that foreshortening (p < 0.01, Cohen’s d: 0.52, CI: −17.81 to −24.83) and heart rate variability (p = 0.02, Cohen’s d: 0.72, CI: −18.07 to −26.23) significantly affect speckle-tracking measurements. While zoom, frame rate, and frequency did not show a significant impact. Additionally, while the 2D strain and AFI exhibited a strong correlation, a significant systematic bias was identified, with AFI underestimating strain values compared to the 2D strain. Intra- and inter-observer coefficients of variation (CV) were below 9% for both methods, supporting their reliability. These findings emphasize the need to optimize image acquisition and selection criteria, which enhances the accuracy and reliability of the speckle-tracking analysis.
29 October 2025 in Veterinary Research Communications
Cardiac tumors are rare and linked to high mortality rates in both human and veterinary medicine. Despite their clinical significance, the effects of these tumors on coagulation and cardiac function remain poorly understood. This retrospective study assessed coagulation profiles and echocardiographic parameters in 14 dogs with cardiac tumors compared to 10 healthy controls. Tumors were identified through echocardiography, with further confirmation by computed tomography/magnetic resonance imaging. Coagulation was evaluated using conventional tests (prothrombin time (PT) and activated partial thromboplastin time (aPTT)) and thromboelastography (TEG). The employed conventional coagulation tests and echocardiographic parameters showed no significant differences between the groups. However, TEG revealed a hypercoagulable state in the majority of tumor-bearing dogs (8 out of 14), characterized by shortened reaction and clot formation times, as well as an increased α-angle and coagulation index (p < 0.05–0.001). No significant correlations were found between TEG parameters and echocardiographic indices. This study is the first to demonstrate subclinical hemostatic alterations using TEG in dogs with cardiac neoplasia. The results support the utility of TEG as a more sensitive tool than conventional tests for detecting hypercoagulability, potentially guiding individualized anticoagulant strategies in affected dogs.
1 January 2024 in Kafkas Universitesi Veteriner Fakultesi Dergisi
Infective endocarditis (IE) is a rare but potentially fatal cause of feline arterial thromboembolism (ATE), most commonly affecting the mitral or aortic valves. Although Enterococcus faecalis is rarely reported in cats, it can induce severe endocardial infection and systemic embolic complications. This case report describes a one-year-old neutered male British Longhair cat that presented with acute hindlimb paralysis and dyspnoea lasting one day. The cat had a three-month history of lower urinary tract infection, but no known cardiac disease. On admission, all the classical signs of arterial obstruction were evident. Laboratory tests revealed neutrophilic leukocytosis and markedly increased serum amyloid A, indicating systemic inflammation. Echocardiography revealed thickened aortic valve leaflets with irregular vegetations and severe regurgitation, with no evidence of intracardiac thrombus. Left ventricular systolic function assessed by two-dimensional speckle-tracking echocardiography was mildly reduced compared with reference values. Blood culture confirmed the presence of E. faecalis, which was susceptible to β-lactams but intrinsically resistant to cephalosporins. Initial empirical therapy included furosemide, low-molecular-weight heparin, and broad-spectrum antibiotics. This was later adjusted to ampicillin–sulbactam, and metronidazole upon receiving the culture results. This report emphasises the importance of considering xone,E. faecalis-associated infective aortic endocarditis in the diagnostic and therapeutic evaluation of feline ATE cases.
Although breast cancer has been associated with subclinical left ventricular dysfunction in humans, the cardiac effects of CMTs remain poorly defined. This pilot, exploratory (communication) study compared clinical and echocardiographic parameters between dogs with CMTs and healthy controls and assessed the feasibility of combining myocardial deformation imaging with exploratory data-driven analysis for preoperative cardiac assessment. All dogs underwent a standardized clinical and echocardiographic assessment, including two-dimensional speckle-tracking echocardiography (2D-STE). Given the limited sample size, analyses were designed to generate hypotheses rather than to provide definitive predictive conclusions. Exploratory machine learning modeling (XGBoost), receiver operating characteristic (ROC) analysis, calibration, and decision curve analysis were performed as proof-of-concept approaches without external validation. Despite normal conventional systolic indices, dogs with CMTs exhibited reduced global longitudinal strain (GLS) and mitral annular plane systolic excursion (MAPSE) (p < 0.01), suggesting subclinical systolic dysfunction. Deformation-derived parameters appeared more sensitive for detecting subtle myocardial alterations within this cohort. The exploratory machine learning model demonstrated moderate discrimination (AUC-ROC = 0.75); however, these findings are preliminary and should not be interpreted as evidence of clinical predictive performance. Overall, these results suggest that conventional systolic indices may underestimate early myocardial changes in dogs with CMTs. This communication highlights the feasibility of integrating deformation imaging with exploratory analytical approaches and provides a basis for future large-scale, validated studies in veterinary cardio-oncology.