Qian Lu

Prof. Dr. Qian Lu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019 in Science Progress
Verified
Journal Article
Open access
PDF file
QLQian Lu
Qian Lu
XCXifu Chen
Xifu Chen
The existing nano-positioning stages are driven by the piezoelectric ceramics, which have features of high accuracy and resolution, but the traditional positioning stage could not meet the requirement of large working space because the displacement of the piezoelectric ceramics is only tens of microns. To solve the contradiction between high accuracy and large working space, a novel non-resonant piezoelectric linear actuator, which adopted the two parallel v-shaped stators as the double driving feet, was proposed, and both its working principle and structure were discussed in detail. The actuator was used to drive the positioning stage directly to obtain the performance of nano-positioning and large working stroke. The experiment results show that the resolution of the actuator is 0.015 μm, and its stable maximum motion speed is 17.4 mm/s, while the degree-of-freedom of step resolution of teach nano-positioning stage is 0.018 μm, 0.016 μm, and 0.3 μrad, respectively. Compared with the traditional positioning stage, the nano-positioning stage driven by the actuators directly also has excellent working stroke. The key performance of both high resolution and large working stroke of the nano-positioning stage was realized based on different motion modes of only one piezoelectric actuator.

13 September 2019 in International Journal of Precision Engineering and Manufacturing
Verified
Journal Article
Closed access
PDF file
XCXifu Chen
Xifu Chen
MLMing Li
Ming Li
HZHuixia Zhang
Huixia Zhang
QLQian Lu
Qian Lu
SLSung-ki Lyu
Sung-ki Lyu

29 September 2022 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
CWChengyang Wang
Chengyang Wang
QLQian Lu
Qian Lu
KZKaikai Zhang
Kaikai Zhang
LSLi Shao
Li Shao
Micro-vibration seriously affects the precision and stability of precision mechanical systems. Aiming at the micro-vibration existing in the semiconductor package positioning system, this paper first designed an active-passive integrated actuator (APIA) based on piezo-stack array, which compensated the mechanical error through the piezo-stack array to improve its positioning accuracy. Based on the APIA, a 6-PUU parallel micro-vibration suppression platform (MVSP) was designed, in which the two APIAs were combined into one and installed on the lower platform along the tangential distribution of the circle, and then the kinematic model of the platform was established. Finally, the PID control algorithm was used to conduct vibration isolation experiments on the MVSP. The experimental results showed that the MVSP had good vibration isolation performance for micro-vibration, the vibration isolation frequency band was above 5 Hz, and the attenuation of micro-vibration signals was between 18% and 64%.

20 November 2019 in International Journal of Precision Engineering and Manufacturing
Verified
Journal Article
Closed access
PDF file
QLQian Lu
Qian Lu
XCXifu Chen
Xifu Chen
LZLei Zheng
Lei Zheng
NXNing Xu
Ning Xu

3 September 2021 in Mechanical Sciences
Verified
Journal Article
Open access
PDF file
QLQian Lu
Qian Lu
CWChengyang Wang
Chengyang Wang
KZKaikai Zhang
Kaikai Zhang
HGHong Gao
Hong Gao
In order to improve the key performance of the compliant actuators, it is necessary to parametrically optimize the compliant actuators based on the compliance features of flexible hinges. A new structural parameter λ, the compliance ratio, which could reflect the sensitivity of the main form of the output displacement, was proposed and analyzed in detail. A compliant lever actuator was developed, and it was optimized by making use of the parameter λ. The optimization was also validated by finite element method (FEM) simulation and experiment. The simulation and experiment results both show that the magnification ratio of the compliant actuator could be enlarged effectively based on the compliance features of flexible hinges. Finally, an actual application of the linear positioning platform that was driven by the compliant lever actuator directly was carried out, and the experiment data also show that the platform with the optimized actuator has different degrees of optimization in terms of the key performance, including the resolution, the motion speed, and the working stroke. It is helpful to develop the compliant actuators and apply it into the precision engineering.

1 May 2025 in Materials Research Express
Verified
Journal Article
Open access
QLQian Lu
Qian Lu
MBMengmeng Bai
Mengmeng Bai
DLDongming Lv
Dongming Lv
CMChao Ma
Chao Ma
BZBowen Zhao
Bowen Zhao
CWChengyang Wang
Chengyang Wang
Aiming at the problem that the hysteresis nonlinearity of piezoelectric ceramics affects the positioning accuracy of micro-nano equipment, a composite control method based on Duhem model is studied. Firstly, the Duhem model is established and the parameters are identified, and the inverse model is taken as the feedforward control. Then, the fuzzy PID feedback control is designed. Finally, the feedforward combined with fuzzy PID feedback are used to control the piezoelectric ceramics. The simulation results show when the input signal frequency is 1 Hz, 15 Hz, 30 Hz and 50 Hz, the root mean square of feedforward combined with fuzzy PID feedback control is reduced by 0.0168 um, 0.0168 um, 0.0413 um, 0.0738 um, and 0.0016 um, 0.003 um, 0.0036 um, 0.0071 um respectively compared with single feedforward control and feedforward combined with PID compound control. The piezoelectric ceramic is applied to the micro-vibration suppression platform (MVSP) as an actuator. The experimental results show when the excitation frequency is 5 Hz, 15 H, 25 Hz, 30 Hz, 35 Hz, 50 Hz, the active and passive control of feedforward combined with fuzzy PID feedback composite control, compared with feedforward combined with PID composite control, the attenuation effect of vibration amplitude is increased by 6%, 8%, 9%, 7%, 15%, 5%. Compared with the active and passive control with single feedforward control, the attenuation effect of vibration amplitude is increased by 11%, 13%, 14%, 13%, 37% and 34% respectively, which proves the effectiveness of the control method and provides reference and theoretical basis for further suppressing the micro-vibration of high-precision equipment.