Background: Though Limbal Relaxing Incisions (LRI) were used widely to correct pre-existing corneal astigmatism during cataract surgery, they have been replaced recently with the more expensive methods like the use of toric Intra Ocular Lenses (IOL) and femtosecond during cataract surgery. We conducted our study to re-evaluate the role of (LRI) in correcting pre-existing moderate corneal astigmatism during cataract surgery in settings where other options are neither available nor affordable. Methods: Retrospective analysis of all consecutive cases of LRI performed by a single surgeon at the time of cataract surgery to correct moderate corneal astigmatism (1.5-3D) in a community hospital over a period of 6 months. Corneal astigmatism, uncorrected distance visual acuity (UDVA) and best corrected distance visual acuity (CDVA) were recorded pre-operatively, 4 weeks and 3 months post-operatively. Data on age, intraocular lens (IOL) power, predictive refraction and post-operative spherical equivalent was also collected and analyzed. The number and position of LRI was determined based on the pre-existing corneal astigmatism using online calculator. Results: 29 eyes of 25 patients with the mean age of 73.6 years (range: 46 to 90 years) and corneal astigmatism between 1.5 to 3D were included. Statistically significant reduction in the mean corneal astigmatism was recorded from 2.05 ± 0.45D preoperatively to 0.85 ± 0.56D postoperatively (P < 0.0001). All eyes showed reduction in astigmatism; 83% of eyes had < 1.0D post-operatively and 66% of eyes had < 0.75D. UDVA of 6/9 or better was recorded in 80% of eyes post-operatively (CDVA of 6/9 or better in 100%). The spherical equivalent was within 1.0D of the predictive refraction postoperatively in nearly all eyes (97%) and within 0.5D in 86% of the eyes. There were no peri-operative or post-operative complications were recorded in any case. Conclusion: Combining LRI and cataract surgery to address moderate degrees of corneal astigmatism is a safe, reliable and predictable option especially in areas where more expensive methods such as toric IOL or excimer laser are not available or affordable. LRI has no significant effect on the spherical equivalent and is an excellent tool in reducing patient’s spectacle dependence.
Objective Increased screen time has resulted in widespread computer vision syndrome (CVS) in the digital era. Medical students, who rely heavily on digital screens, are particularly at risk. Our study aims to evaluate the prevalence of CVS among Jordanian medical students, which is a gap in existing knowledge. Design Cross-sectional study Setting National multicentre study conducted across six universities in Jordan. Participants Medical students from first to sixth year. Primary and secondary outcome measures Primary outcome: Prevalence of CVS among medical students in Jordan. Secondary outcomes: Identification of risk factors associated with CVS, assessment of the correlation between screen time and the severity of CVS symptoms. Results The prevalence of CVS among medical students was 56.3%. Among the 833 participants, 543 were females (65.2%) and 290 were males (34.8%). The CVS group reported a median of five symptoms, whereas two symptoms were reported in the non-CVS group (p<0.001). Compared with males, females reported significantly more symptoms (p<0.001). Dry eyes (26.3%) and headaches (25.9%) were the most reported symptoms. Continuous screen use was associated with CVS group status (p=0.008). Moderate positive correlations were found between the number of symptoms and the frequency of monthly symptom attacks and between the duration and frequency of symptom attacks (p<0.001). Conclusion Our study found a 56.3% prevalence of CVS among Jordanian medical students, with over 80% having ocular and extraocular symptoms. Symptoms, attack duration and frequency were higher, especially in females, highlighting the need for preventive measures and increased awareness about prolonged screen use.
1 March 2021 in Diabetes, Metabolic Syndrome and Obesity
Purpose: This study aimed to investigate the attitudes and awareness about the development of retinopathy among the patients suffering from diabetes in Amman, Jordan. Methods: A questionnaire was distributed among patients with diabetes visiting internal medicine and endocrinology clinics in a tertiary hospital, in addition to a primary health care center in Amman. The questionnaire inquired about retinopathy awareness, history of screening for retinopathy, and awareness about retinopathy treatment. The patients were also asked about risk factors and preventive measures for diabetic retinopathy management. Results: A total of 303 patients were recruited in the study. Majority of the patients (77%) had their HbA1c levels tested at least once since diagnosis, and most of them (60%) do it regularly. However, 86% of patients reported an A1c > 6.5%. Two thirds of patients are not aware about retinopathy being a recognized complication of diabetes. Lower level of education, female sex, younger age, and shorter duration of diabetes mellitus were associated with less awareness. Conclusion: The study concluded that majority of patients with diabetes were aware of diabetes management. However, the sample population indicated less awareness of diabetic retinopathy. Hence, more educational efforts are needed to further boost patients’ awareness about diabetic retinopathy.
A Computerized Medical Image Processing (CMIP) method is proposed to address the current challenges of optical coherence tomography angiography (OCTA): (1) the need for observing the macula vasculature concerning natural curvature of the macula region; (2) the need for generating OCTA frames at successive small depths in all macula layers; and (3) the need for enhancing the visibility of blood vessels, particularly below the outer retina region. The proposed CMIP method involves image preprocessing, reconstruction, and enhancement stages. Twenty subjects were obtained from the OCTA500 dataset, which was obtained from the OptoVue OCTA machine. The 20 subjects comprise the two OCTA fields of view (FOV), right and left eyes (OD and OS), and five common macula disorders. The sequential enface OCTA images at 5μm macula depths were displayed. The presentation of the macula vasculature was enhanced at all depths. The resulting new ophthalmic views enable: (1) avoiding the superimposition of macula vasculature into a projection map; (2) enhancing the OCTA presentation of blood vessels; and (3) inspecting the macula’s 3D oval-shaped. The proposed CMIP method can generate sectional macula coronal views (MCV) for every 5μm depth, clarifying the macula’s curvature in a way that has not been presented in OCTA machines. Therefore, “tracking” the 3D propagation of the blood vessel network at all macula depths becomes possible. Furthermore, the blood vessels’ display at all macula depths, including the deep choroid layers, is enhanced. The method yields futuristic ophthalmic advantages that would allow the physician to precisely inspect the 3D localization and diffusion of the macula disorders. The method is invariant to the OCTA’s FOVs, macula disorder, and OD or OS eye.
Purpose: To analyze the real-life clinical outcome of a single dexamethasone implant (DEX) injection in the treatment of persistent diabetic macular edema (DME) after anti-vascular endothelial growth factor (anti-VEGF) agents in a sample of the Jordanian population. Methods: An observational case study design that involved a retrospective chart review analysis in a tertiary hospital in Amman, Jordan. Patients who showed persistent DME after receiving at least six doses of anti-VEGF agents for DME treatment were included. Results: The study population consisted of 72 participants (29 females, 43 males) having an average age of 66 years. All patients had best-corrected visual acuity (BCVA) less than 0.7 (6/9) and SD-OCT documented center-involved DME. The study results showed that the average baseline BCVA improved from 0.205 +/- 0.1 before DEX injection to 0.358 +/- 0.1 at 3 months post-injection (p<0.0001). The central mean thickness (CMT) showed significant improvement also (539.347 +/- 132.402 to 379.041 +/- 99.430, p<0.0001). There was a mean of 3 mmHg increase in intraocular pressure at 3 months post-injection (p<0.0001), however, only 4% of patients required medical treatment. Other inflammatory biomarkers in OCT, such as intraretinal hyper-reflective dots (HRD), showed significant improvement also (23.67 +/- 16 to 14.83 +/- 13, p<0.0001). No other significant safety concerns were noticed. Conclusion: A single DEX injection showed significant clinical and anatomical improvement in DME cases that are persistent after anti-VEGF treatment in our sample, with an excellent safety profile. In case of supply shortage of intravitreal injections, which occurs frequently at our center, a single DEX injection may be utilized as an effective DME therapy. Further research is mandated to identify clinical response in a larger sample and more frequent injections.
1 November 2023 in Journal of Multidisciplinary Healthcare
Dove Press is a member of the Open Access Initiative, specializing in peer reviewed Medical Journals. View articlesor submit your research for publishing