Pádraig Cantillon-Murphy

Pádraig Cantillon-Murphy


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2011 in Gastrointestinal Endoscopy
Verified
Journal Article
Closed access
MRMarvin Ryou
Marvin Ryou
PCPádraig Cantillon-Murphy
Pádraig Cantillon-Murphy
DADan Azagury
Dan Azagury
SSSohail N. Shaikh
Sohail N. Shaikh
GHGabriel Ha
Gabriel Ha
CTChristopher C. Thompson
Christopher C. Thompson

29 March 2017 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
HJHerman Alexander Jaeger
Herman Alexander Jaeger
AFAlfred Michael Franz
Alfred Michael Franz
KOKilian O’dOnoghue
Kilian O’dOnoghue
ASAlexander Seitel
Alexander Seitel
FTFabian Trauzettel
Fabian Trauzettel
PCPádraig Cantillon-Murphy
Pádraig Cantillon-Murphy

4 February 2014 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
KOKilian O'DOnoghue
Kilian O'DOnoghue
DEDavid Eustace
David Eustace
JGJames Griffiths
James Griffiths
MOMichael O'SHea
Michael O'SHea
TPTimothy Power
Timothy Power
PCPádraig Cantillon-Murphy
Pádraig Cantillon-Murphy
This paper presents an electromagnetic system for five degrees of freedom position and orientation sensing with application in a virtual bronchoscopy system. Planar magnetic source coils were manufactured on printed circuit boards for reproducibility and low-cost manufacturing. The exact magnetic field of each coil is calculated using a filament-based approach. A constant ac current amplifier is used to drive each coil at an independent frequency and a synchronous demodulator calculates each associated magnetic field component using the current waveform as a reference signal. Commercially available search coil sensors are used and a comparison between shielded and unshielded probes is presented. Extensive testing with two separate methods has shown the accuracy of the system to be between 1 and 2 mm. The use of a novel closed loop coil driver has been found to offer excellent magnetic field stability and significant reduction in crosstalk interference.

26 June 2015 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
PNPietro Nardelli
Pietro Nardelli
KKKashif A Khan
Kashif A Khan
ACAlberto Corvò
Alberto Corvò
NMNiamh Moore
Niamh Moore
MMMary J Murphy
Mary J Murphy
PCPádraig Cantillon-Murphy
Pádraig Cantillon-Murphy
Computed tomography (CT) helps physicians locate and diagnose pathological conditions. In some conditions, having an airway segmentation method which facilitates reconstruction of the airway from chest CT images can help hugely in the assessment of lung diseases. Many efforts have been made to develop airway segmentation algorithms, but methods are usually not optimized to be reliable across different CT scan parameters.

22 March 2016 in Advances in Therapy
Verified
Journal Article
Open access
PDF file
KKKashif Ali Khan
Kashif Ali Khan
PNPietro Nardelli
Pietro Nardelli
HJHerman Alexander Jaeger
Herman Alexander Jaeger
COConor O’sHea
Conor O’sHea
PCPádraig Cantillon-Murphy
Pádraig Cantillon-Murphy
MKMarcus P. Kennedy
Marcus P. Kennedy
Peripheral lung nodules remain challenging for accurate localization and diagnosis. Once identified, there are many strategies for diagnosis with heterogeneous risk benefit analysis. Traditional strategies such as conventional bronchoscopy have poor performance in locating and acquiring the required tissue. Similarly, while computerized-assisted transthoracic needle biopsy is currently the favored diagnostic procedure, it is associated with complications such as pneumothorax and hemorrhage. Video-assisted thoracoscopic and open surgical biopsies are invasive, require general anesthesia and are therefore not a first-line approach. New techniques such as ultrathin bronchoscopy and image-based guidance technologies are evolving to improve the diagnosis of peripheral lung lesions. Virtual bronchoscopy and electromagnetic navigation systems are novel technologies based on assisted-computerized tomography images that guide the bronchoscopist toward the target peripheral lesion. This article provides a comprehensive review of these emerging technologies.

1 March 2010 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Open access
PCPádraig Cantillon-Murphy
Pádraig Cantillon-Murphy
LWL.L. Wald
L.L. Wald
EAE. Adalsteinsson
E. Adalsteinsson
MZMarkus Zahn
Markus Zahn
In the presence of alternating-sinusoidal or rotating magnetic fields, magnetic nanoparticles will act to realign their magnetic moment with the applied magnetic field. The realignment is characterized by the nanoparticle’s time constant, τ. As the magnetic field frequency is increased, the nanoparticle’s magnetic moment lags the applied magnetic field at a constant angle for a given frequency, Ω, in rad/s. Associated with this misalignment is a power dissipation that increases the bulk magnetic fluid’s temperature which has been utilized as a method of magnetic nanoparticle hyperthermia, particularly suited for cancer in low-perfusion tissue (e.g., breast) where temperature increases of between 4°C and 7°C above the ambient in vivo temperature cause tumor hyperthermia. This work examines the rise in the magnetic fluid’s temperature in the MRI environment which is characterized by a large DC field, B0. Theoretical analysis and simulation is used to predict the effect of both alternating-sinusoidal and rotating magnetic fields transverse to B0. Results are presented for the expected temperature increase in small tumors (~1 cm radius) over an appropriate range of magnetic fluid concentrations (0.002 to 0.01 solid volume fraction) and nanoparticle radii (1 to 10 nm). The results indicate that significant heating can take place, even in low-field MRI systems where magnetic fluid saturation is not significant, with careful selection of the rotating or sinusoidal field parameters (field frequency and amplitude). The work indicates that it may be feasible to combine low-field MRI with a magnetic hyperthermia system using superparamagnetic iron oxide nanoparticles.