Fabian Trauzettel

Fabian Trauzettel

Auto-generated profile, based on publicly available information

Fabian Trauzettel

Department of Mechanical Engineering, Katholieke Universiteit Leuven, Leuven, Belgium

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
DWDi Wu
Di Wu
XHXuan Thao Ha
Xuan Thao Ha
YZYao Zhang
Yao Zhang
MOMouloud Ourak
Mouloud Ourak
GBGianni Borghesan
Gianni Borghesan
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten
In cardiovascular interventions, when steering catheters and especially robotic catheters, great care should be paid to prevent applying too large forces on the vessel walls as this could dislodge calcifications, induce scars or even cause perforation. To address this challenge, this paper presents a novel compliant motion control algorithm that relies solely on position sensing of the catheter tip and knowledge of the catheter’s behavior. The proposed algorithm features a data-driven tip position controller. The controller is trained based on a so-called control Long Short-Term Memory Network (control-LSTM). Trajectory following experiments are conducted to validate the quality of the proposed control-LSTM. Results demonstrated superior positioning capability with sub-degree precision of the new approach in the presence of severe rate-dependent hysteresis. Experiments both in a simplified setup as well as in an aortic phantom further show that the proposed approach allows reducing the interaction forces with the environment by around 70%. This work shows how deep learning can be exploited advantageously to avoid tedious modeling that would be needed to precisely steer continuum robots in constrained environments such as the patient’s vasculature.

29 March 2017 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
HJHerman Alexander Jaeger
Herman Alexander Jaeger
AFAlfred Michael Franz
Alfred Michael Franz
KOKilian O’dOnoghue
Kilian O’dOnoghue
ASAlexander Seitel
Alexander Seitel
FTFabian Trauzettel
Fabian Trauzettel
PCPádraig Cantillon-Murphy
Pádraig Cantillon-Murphy

20 September 2021 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Closed access
CCCostanza Culmone
Costanza Culmone
FYFatih S. Yikilmaz
Fatih S. Yikilmaz
FTFabian Trauzettel
Fabian Trauzettel
PBPaul Breedveld
Paul Breedveld
Conventional medical instruments are not capable of passing through tortuous anatomy as required for natural orifice transluminal endoscopic surgery due to their rigid shaft designs. Nevertheless, developments in minimally invasive surgery are pushing medical devices to become more dexterous. Amongst devices with controllable flexibility, so-called Follow-The-Leader (FTL) devices possess motion capabilities to pass through confined spaces without interacting with anatomical structures. The goal of this literature study is to provide a comprehensive overview of medical devices with FTL motion. A scientific and patent literature search was performed in five databases. Keywords were used to isolate FTL behavior in devices with medical applications. Ultimately, 35 unique devices were reviewed and categorized. Devices were allocated according to their design strategies to obtain the three fundamental sub-functions of FTL motion: steering, propagation, and conservation. A comparative analysis of the devices was carried out, showing the commonly used design choices for each sub-function and the different combinations. The advantages and disadvantages of the design aspects and an overview of their performance were provided. Devices that were initially assessed as ineligible were considered in a possible medical context or presented with FTL potential, broadening the classification.

7 September 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JBJette Bloemberg
Jette Bloemberg
FTFabian Trauzettel
Fabian Trauzettel
BCBram Coolen
Bram Coolen
DDDimitra Dodou
Dimitra Dodou
PBPaul Breedveld
Paul Breedveld
Prostate cancer diagnosis and focal laser ablation treatment both require the insertion of a needle for biopsy and optical fibre positioning. Needle insertion in soft tissues may cause tissue motion and deformation, which can, in turn, result in tissue damage and needle positioning errors. In this study, we present a prototype system making use of a wasp-inspired (bioinspired) self-propelled needle, which is able to move forward with zero external push force, thereby avoiding large tissue motion and deformation. Additionally, the actuation system solely consists of 3D printed parts and is therefore safe to use inside a magnetic resonance imaging (MRI) system. The needle consists of six parallel 0.25-mm diameter Nitinol rods driven by the actuation system. In the prototype, the self-propelled motion is achieved by advancing one needle segment while retracting the others. The advancing needle segment has to overcome a cutting and friction force while the retracting needle segments experience a friction force in the opposite direction. The needle self-propels through the tissue when the friction force of the five retracting needle segments overcomes the sum of the friction and cutting forces of the advancing needle segment. We tested the performance of the prototype in ex vivo human prostate tissue inside a preclinical MRI system in terms of the slip ratio of the needle with respect to the prostate tissue. The results showed that the needle was visible in MR images and that the needle was able to self-propel through the tissue with a slip ratio in the range of 0.78–0.95. The prototype is a step toward self-propelled needles for MRI-guided transperineal laser ablation as a method to treat prostate cancer.

6 December 2019 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
SKShingo Kanaji
Shingo Kanaji
RWRyohei Watanabe
Ryohei Watanabe
PMPietro Mascagni
Pietro Mascagni
FTFabian Trauzettel
Fabian Trauzettel
TUTakeshi Urade
Takeshi Urade
Jacques MarescauxJacques Marescaux
Jacques Marescaux

2 November 2018 in Minimally Invasive Therapy & Allied Technologies
Verified
Journal Article
Closed access
HJHerman Alexander Jaeger
Herman Alexander Jaeger
FTFabian Trauzettel
Fabian Trauzettel
PNPietro Nardelli
Pietro Nardelli
FDFederico Daverieux
Federico Daverieux
EHErlend Fagertun Hofstad
Erlend Fagertun Hofstad
PCPádraig Cantillon-Murphy
Pádraig Cantillon-Murphy
Objectives: The goal was to demonstrate the utility of open-source tracking and visualisation tools in the targeting of lung cancer. Material and methods: The study demonstrates the first deployment of the Anser electromagnetic (EM) tracking system with the CustusX image-guided interventional research platform to navigate using an endobronchial catheter to injected tumour targets. Live animal investigations validated the deployment and targeting of peripheral tumour models using an innovative tumour marking routine. Results: Novel tumour model deployment was successfully achieved at all eight target sites across two live animal investigations without pneumothorax. Virtual bronchoscopy with tracking successfully guided the tracked catheter to 2–12 mm from the target tumour site. Deployment of a novel marker was achieved at all eight sites providing a reliable measure of targeting accuracy. Targeting accuracy within 10 mm was achieved in 7/8 sites and in all cases, the virtual target distance at marker deployment was within the range subsequently measured with x-ray. Conclusions: Endobronchial targeting of peripheral airway targets is feasible using existing open-source technology. Notwithstanding the shortcomings of current commercial platforms, technological improvements in EM tracking and registration accuracy fostered by open-source technology may provide the impetus for widespread clinical uptake of electromagnetic navigation in bronchoscopy.