Juliane Alberts

Ms. Juliane Alberts

orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1990 in Environmental Technology
Verified
Journal Article
Closed access
JWJ.H. Weber
J.H. Weber
JAJuliane Alberts
Juliane Alberts
Incubation of Spartina alterniflora plants for five days in tin‐amended Hoaglund's solutions increased their inorganic tin and methyltin concentrations in 9 of 10 samples. Compared to control plants, roots, but not leaves, accumulated considerable inorganic tin from solution. Mono‐and dimethyltin concentrations in leaves of treated plants were not significantly enhanced from concentrations in the control plant. However, trimethyltin, which was not detected in control leaves, had the highest concentration of any methyltin compound in treated plants.

1 April 1995 in Environmental Science & Technology
Verified
Journal Article
Closed access
ZGZhengfang. Ge
Zhengfang. Ge
CBChris W. Brown
Chris W. Brown
JAJuliane Alberts
Juliane Alberts

16 August 2024 in Communications in Development and Assembling of Textile Products
Verified
Journal Article
Open access
PDF file
JAJuliane Alberts
Juliane Alberts
EGEva Glink
Eva Glink
ECEdith Classen
Edith Classen
When textiles are washed, natural and synthetic fibres are released that cannot completely be retained by waste water treatment plants. These microfibres can enter freshwater ecosystems and marine habitats and have unpredictable negative effects on the environment. Until now, there has been no standardised approach for determining the environmental impact of microfibres released during washing. Against this background, a new test procedure to investigate and classify the environmental impact of textiles during laundering was developed (DIN SPEC 4872). In this test procedure, textiles are classified with regard to fibre release during the washing process using a suitable analysis system – the Dynamic Image Analysis. In addition, the microfibre release is classified by testing its biodegradability in waste water using a respirometer system. Finally, a suitable ecotoxicity test with a model aquatic organism (Lemna minor) is carried out, to determine the toxicity of the fibre residues after the biodegradation process. With this holistic test procedure, it is possible to investigate the environmental impact of synthetic microfibres (microplastics), as well as natural microfibres in a standardised way. The consideration of textiles made of natural fibres is just as important as the consideration of synthetic ones, because their fibre release capacity, biodegradability and ecotoxicity can be influenced by textile finishes such as dyes and can therefore also pose a risk to the environment.

8 May 2026 in Clean Technologies
Verified
Journal Article
Open access
PDF file
IKIgor Kogut
Igor Kogut
JAJuliane Alberts
Juliane Alberts
BWBianca-Michaela Wölfling
Bianca-Michaela Wölfling
SHStephan Hussy
Stephan Hussy
DPDaniel Polak
Daniel Polak
Maciej SzwastMaciej Szwast
Maciej Szwast
Domestic wastewater is a chemically complex and highly variable mixture of pollutants generated by everyday household activities, yet its contribution to environmental contamination is still frequently underestimated and only 56% of wastewater worldwide is being treated. This review provides a structured and quantitative assessment of major domestic wastewater pollutant groups, their principal exposure pathways, and current and emerging treatment technologies. Beyond a conventional narrative synthesis, the review derives per capita annual emission estimates from published data and uses these to compare pollutant groups by mass flow and environmental relevance. The analysis shows that high-volume household inputs, particularly sodium chloride from domestic water softening, toilet paper, personal-care products, detergents, and cleaning agents, can contribute substantially to overall pollutant loads, whereas lower-mass contaminants such as pharmaceuticals, antibiotics, PFAS, heavy metals, and microplastics remain critical because of their persistence, biological activity, and incomplete removal during treatment. The review further highlights that conventional wastewater treatment systems are often poorly equipped to remove many of these emerging contaminants effectively, especially under decentralised or only partially advanced treatment conditions. Advanced and hybrid technologies, including membrane bioreactors, nanofiltration, reverse osmosis, adsorption, photocatalysis, and electrochemical processes, offer clear potential, but their broader implementation remains constrained by cost, energy demand, fouling, and concentrate management. Overall, the added value of this review lies in linking mass-based pollutant prioritisation with treatment performance, thereby providing a more systematic basis for identifying dominant household emission pathways and for guiding targeted mitigation and technology selection in future wastewater management.