This study aims to evaluate and compare the performance of five publicly accessible large-language-model (LLM) based chatbots—ChatGPT-o1, Deepseek-R1, Google-Gemini-Advanced, Claude-3.5-Sonnet, and Perplexity-Pro—in providing responses to frequently asked questions (FAQs) about dental implant treatment. The primary goal was to assess the accuracy, completeness, clarity, relevance, and consistency of chatbot-generated answers. A total of 45 FAQs commonly encountered in clinical practice and online patient forums regarding dental implants were selected and categorized into nine thematic domains. Each question was submitted to the chatbots individually using a standardized protocol. Responses were independently assessed by a panel of four dental experts and one layperson using a 5-point Likert-scale. Python with Google-Colab was used for statistical analysis. ChatGPT-o1 achieved the highest overall performance, particularly in relevance (M = 4.99), consistency (M = 4.97), and accuracy (M = 4.96). Deepseek-R1 followed closely, with strong scores in completeness and relevance. Claude-3.5-Sonnet ranked moderately, while Gemini-Advanced and Perplexity-Pro showed lower performance in completeness and clarity. Significant differences were observed among chatbots across all criteria (p < 0.001). Inter-rater reliability was high (α = 0.87), confirming consistency among evaluators. AI-driven chatbots demonstrated strong potential in delivering accurate and patient-friendly information about dental implant treatment. However, performance varied considerably across platforms, with ChatGPT-o1 and Deepseek-R1 showing the highest reliability. These findings highlight the emerging role of AI chatbots as supplementary tools in dental education and patient communication, while also underscoring the need for continued validation and ethical oversight in clinical applications.
Immediate-loading full-arch concepts such as All-on-4, Trefoil, and Five-Implant protocols are widely used for mandibular rehabilitation, yet their compara
Low-density cancellous bone results in reduced trabecular support and may increase crestal cortical strain around implants. Osseodensification (OD) compacts trabecular bone and may create a peri-osteotomy densified zone, but its strain-level effects in osteoporotic-like bone are unclear. This study evaluated whether an OD-inspired peri-implant densified trabecular zone reduces crestal cortical strain compared with conventional drilling (CD) in an osteoporotic-like model. A three-dimensional finite element model of a mandibular posterior segment with a 2.0-mm cortical shell and D4 cancellous core was constructed with a 4.3 × 11.4-mm titanium implant and a cemented monolithic zirconia crown. CD used a 4.0-mm osteotomy in D4 bone. The OD model used the same osteotomy plus a concentric peri-implant densified shell with radial density gradation from D1 to D3. The implant–bone interface was defined as bonded. Static 100 N axial and 45° oblique loads were applied. Outcomes were εeq, εmax, and εmin, summarized as mean top-10 nodal values. OD reduced crestal cortical strains under both loads. Under axial loading, εeq, εmax, and |εmin| decreased by 17.7%, 19.0%, and 24.1%, respectively. Under oblique loading, the corresponding reductions were 9.8%, 8.0%, and 8.9%. Oblique loading produced higher cortical strains than axial loading in both models. OD-inspired peri-implant densification reduced crestal cortical strain in this osteoporotic-like model, whereas oblique loading remained the main driver of elevated strain. These findings support occlusal/prosthetic strategies that minimize oblique forces and warrant experimental and clinical validation.
Background/Objectives: Low-density cancellous bone can amplify crestal cortical strain around implants because trabecular support is reduced. Osseodensification (OD) compacts trabecular bone and may create a peri-osteotomy densified zone, but its strain-level effects in osteoporotic-like bone are unclear. Given that osteoporosis/osteopenia in aging populations reduce trabecular support and can increase crestal cortical loading, this study tested whether an OD-inspired peri-implant densified trabecular zone lowers high-tail crestal cortical strains versus conventional drilling in an osteoporotic-like cancellous model. Materials and Methods: A 3D finite element mandibular posterior segment (2.0-mm cortical shell and D4 cancellous core) was modeled with a 4.3×11.4-mm titanium implant and a cemented monolithic zirconia crown. CD used a 4.0-mm osteotomy in D4 bone. OD used the same osteotomy plus an axially varying concentric densified shell (D1→D3 radially) with minor buccolingual cortical expansion. The implant–bone interface was bonded. Static 100 N loads were applied axially and obliquely (45°). Outcomes were εeq, εmax, and εmin, summarized as mean top-10 nodal values. Results: OD reduced crestal cortical strains under both loads. Axial loading: εeq 1470→1210 µε (−17.7%), εmax 1420→1150 µε (−19.0%), |εmin| 900→683 µε (−24.1%). Oblique loading: εeq 3370→3040 µε (−9.8%), εmax 2510→2310 µε (−8.0%), |εmin| 3040→2770 µε (−8.9%). Oblique loading produced higher cortical strains than axial loading in both models. Conclusions: OD-inspired peri-implant densification attenuated high-tail crestal cortical strain demand in this osteoporotic-like model, whereas off-axis loading remained the dominant driver of elevated strain. These findings support occlusal/prosthetic strategies that minimize oblique forces and warrant experimental and clinical validation.
Full-arch zirconia prostheses for mandibular All-on-4 rehabilitations are provided as screw-retained monolithic zirconia (Zr-Mono) or as a zirconia suprastructure luted to a CAD/CAM titanium bar (Zr-TiBar). Because zirconia is a brittle and flaw-sensitive ceramic, design assessment should incorporate stress-field-weighted fracture risk. This in silico study compared zirconia tensile stress, deformation, and Weibull-based reliability between Zr-Mono and Zr-TiBar designs in a standardized edentulous mandibular All-on-4 model (posterior implants tilted 30°) using linear static finite element analysis. Accordingly, 300 N posterior unilateral loads were applied at the first molar (axial; 45° oblique). Outcomes were maximum principal tensile stress in zirconia (S1max), total prosthesis deformation, and Weibull-predicted fracture probability (Pf) derived from the tensile S1 field. Under axial loading, S1max was essentially identical between designs (~277 MPa). Under oblique loading, S1max was modestly lower for Zr-TiBar (~227 MPa) than for Zr-Mono (~234 MPa), and deformation was slightly lower for Zr-TiBar (<0.07 mm in all cases). Pf remained very low for both designs (10−6–10−7 range) and differed only slightly between them. Under the modeled single 300 N posterior load case, the titanium-bar support reduced deformation and modestly reduced oblique-load peak tensile stress but did not materially reduce the predicted zirconia Pf compared with monolithic zirconia.
12 March 2026 in Journal of Health Sciences and Medicine
Aims: Three-dimensional (3D) printing of zirconia is an emerging domain in digital dentistry; however, its global research landscape, collaboration structure, and thematic focus have not been comprehensively mapped. The aim of this study was to characterize scientific output, collaboration patterns, citation impact, and major research themes in publications on 3D-printed zirconia in dentistry.Methods: A Web of Science Core Collection (WoS-CC) Topic Search was conducted in December 2025 using terms related to zirconia, additive manufacturing/3D printing, and dental applications. Of 584 retrieved records, 185 eligible articles on 3D-printed zirconia for dental use (2009–2025) were included. Descriptive indicators were calculated (annual production, journals, countries, institutions, authors, and citations). Co-authorship and keyword co-occurrence networks were generated with VOSviewer to visualize collaboration and identify thematic clusters.Results: Publication activity increased sharply after 2019, with 128/185 publications (69.2%) published in 2023–2025. Most documents were original research articles (n=159) or reviews (n=26); no case reports were identified in WoS-CC. The 185 articles involved 730 authors from 38 countries and were published in 48 journals. China and the United States were leading contributors. Network analyses identified three interconnected themes: digital/additive manufacturing workflows, implantprosthodontic applications, and biomechanical or accuracy-based evaluation. Evidence was predominantly in vitro and laboratory-based, with limited clinical data.Conclusion: Research on 3D-printed zirconia in dentistry is rapidly expanding but concentrated in a small set of countries, institutions, and journals. Future studies should prioritize clinical investigations and standardized reporting of printing and post-processing parameters to support translation into predictable outcomes.