We demonstrate pseudo spin valves (PSVs) with a (112)-textured D0 22 Mn 2.3-2.4 Ga (MnGa) tilted magnetization fixed layer and an in-plane CoFe free layer. Single D0 22 MnGa films exhibit a small magnetoresistance (MR) typically observed in metals. In MnGa/Cu/CoFe PSVs, a transition from a negative (-0.08%) to positive (3.88%) MR is realized by introducing a thin spin polarizing CoFe insertion layer at the MnGa/Cu interface and tailoring the MnGa thickness. Finally, the exchange coupling between the MnGa and CoFe insertion layer is studied using a first-order reversal curve technique.
28 January 2013 in International Journal for Numerical Methods in Engineering
In the pulp and paper industry, pulp testing is typically a labor-intensive process performed on hand-made laboratory sheets. Online quality control by automated image analysis and machine learning (ML) could provide a consistent, fast and cost-efficient alternative. In this study, four different supervised ML techniques—Lasso regression, support vector machine (SVM), feed-forward neural networks (FFNN), and recurrent neural networks (RNN)—were applied to fiber data obtained from fiber suspension micrographs analyzed by two separate image analysis software. With the built-in software of a commercial fiber analyzer optimized for speed, the maximum accuracy of 81% was achieved using the FFNN algorithm with Yeo–Johnson preprocessing. With an in-house algorithm adapted for ML by an extended set of particle attributes, a maximum accuracy of 96% was achieved with Lasso regression. A parameter capturing the average intensity of the particle in the micrograph, only available from the latter software, has a particularly strong predictive capability. The high accuracy and sensitivity of the ML results indicate that such a strategy could be very useful for quality control of fiber dispersions.
Traction drive applications demand high power density motors with a good stator cooling design. We propose a novel multi-phase winding for a 48 V traction drive design having identical preformed hollow copper conductors with in-conductor direct cooling capability. This paper studies the cooling performance of an individual conductor phase using either EGW50/50 or water as coolant. Analytical calculations and experiments are conducted on a straight conductor of the same length using 20°C water as coolant. The results are then cross verified with those from the FEM simulations to validate the simulation setup. Then a final simulation is conducted at a current of 700A and a current density of 49.5 $\mathrm{A}/\mathrm{m}\mathrm{m}^{2}$ on the preformed conductor using $65^{\circ}\mathrm{C}\mathrm{E}\mathrm{G}\mathrm{W}50/50$ as coolant at a pressure of $140\mathrm{k}\mathrm{P}\mathrm{a}$. The results highlight the exceptional performance of the cooling design which enables a power dissipation of 71OW at a maximum conductor temperature rise of only 56. $9^{\circ}\mathrm{C}$.
24 December 2024 in International Journal of Fatigue