Matthew A. Schiefer

Matthew A. Schiefer

Auto-generated profile, based on publicly available information

Matthew A. Schiefer

Louis Stokes Cleveland Department of Veterans Affairs Medical Center (LSCDVAMC)

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2014 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
DTDaniel W. Tan
Daniel W. Tan
MSMatthew A. Schiefer
Matthew A. Schiefer
MKMichael W. Keith
Michael W. Keith
JAJames Robert Anderson
James Robert Anderson
JTJoyce Tyler
Joyce Tyler
DTDustin J. Tyler
Dustin J. Tyler
Electrical stimulation, using patterned intensity, applied through cuff-type peripheral nerve interfaces provided stable touch perceptions in the fingers, thumb, and hand of two subjects with upper limb loss for 16 to 24 months.

26 October 2016 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
EGEmily L. Graczyk
Emily L. Graczyk
MSMatthew A. Schiefer
Matthew A. Schiefer
HSHannes Saal
Hannes Saal
BDBenoit P. Delhaye
Benoit P. Delhaye
SBSliman J. Bensmaia
Sliman J. Bensmaia
DTDustin J. Tyler
Dustin J. Tyler
Electrical connections between nerves and a prosthetic device enable amputees to discern precise, graded sensory intensity ranging from light touch to intense pressure.

8 December 2015 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
MSMatthew Schiefer
Matthew Schiefer
DTDaniel Tan
Daniel Tan
SSSteven M Sidek
Steven M Sidek
DTDustin J. Tyler
Dustin J. Tyler
Objective. Tactile feedback is critical to grip and object manipulation. Its absence results in reliance on visual and auditory cues. Our objective was to assess the effect of sensory feedback on task performance in individuals with limb loss. Approach. Stimulation of the peripheral nerves using implanted cuff electrodes provided two subjects with sensory feedback with intensity proportional to forces on the thumb, index, and middle fingers of their prosthetic hand during object manipulation. Both subjects perceived the sensation on their phantom hand at locations corresponding to the locations of the forces on the prosthetic hand. A bend sensor measured prosthetic hand span. Hand span modulated the intensity of sensory feedback perceived on the thenar eminence for subject 1 and the middle finger for subject 2. We performed three functional tests with the blindfolded subjects. First, the subject tried to determine whether or not a wooden block had been placed in his prosthetic hand. Second, the subject had to locate and remove magnetic blocks from a metal table. Third, the subject performed the Southampton Hand Assessment Procedure (SHAP). We also measured the subject’s sense of embodiment with a survey and his self-confidence. Main results. Blindfolded performance with sensory feedback was similar to sighted performance in the wooden block and magnetic block tasks. Performance on the SHAP, a measure of hand mechanical function and control, was similar with and without sensory feedback. An embodiment survey showed an improved sense of integration of the prosthesis in self body image with sensory feedback. Significance. Sensory feedback by peripheral nerve stimulation improved object discrimination and manipulation, embodiment, and confidence. With both forms of feedback, the blindfolded subjects tended toward results obtained with visual feedback.

29 June 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
EGEmily L. Graczyk
Emily L. Graczyk
LRLinda Resnik
Linda Resnik
MSMatthew A. Schiefer
Matthew A. Schiefer
MSMelissa S. Schmitt
Melissa S. Schmitt
DTDustin J. Tyler
Dustin J. Tyler
The loss of a hand has many psychosocial repercussions. While advanced multi-articulated prostheses can improve function, without sensation, they cannot restore the full experience and connection of a hand. Direct nerve interfaces can restore naturalistic sensation to amputees. Our sensory restoration system produced tactile and proprioceptive sensations on the hand via neural stimulation through chronically implanted electrodes. In this study, upper limb amputees used a sensory-enabled prosthesis in their homes and communities, autonomously and unconstrained to specific tasks. These real-life conditions enabled us to study the impact of sensation on prosthetic usage, functional performance, and psychosocial experience. We found that sensory feedback fundamentally altered the way participants used their prosthesis, transforming it from a sporadically-used tool into a readily and frequently-used hand. Functional performance with sensation improved following extended daily use. Restored sensation improved a wide range of psychosocial factors, including self-efficacy, prosthetic embodiment, self-image, social interaction, and quality of life. This study demonstrates that daily use of a sensory-enabled prosthesis restores the holistic experience of having a hand and more fully reconnects amputees with the world.

1 December 2008 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
YGYanina Grinberg
Yanina Grinberg
MSMatthew A. Schiefer
Matthew A. Schiefer
DTDustin J. Tyler
Dustin J. Tyler
KGKenneth J. Gustafson
Kenneth J. Gustafson
The number of applications using neural prosthetic interfaces is expanding. Computer models are a valuable tool to evaluate stimulation techniques and electrode designs. Although our understanding of neural anatomy has improved, its impact on the effects of neural stimulation is not well understood. This study evaluated the effects of fascicle perineurial thickness, diameter, and position on axonal excitation thresholds and population recruitment using finite element models and NEURON simulations. The perineurial thickness of human fascicles was found to be 3.0% plusmn 1.0% of the fascicle diameter. Increased perineurial thickness and fascicle diameter increased activation thresholds. The presence of a large neighboring fascicle caused a significant change in activation of a smaller target fascicle by as much as 80% plusmn 11% of the total axon population. Smaller fascicles were recruited at lower amplitudes than neighboring larger fascicles. These effects were further illustrated in a realistic model of a human femoral nerve surrounded by a nerve cuff electrode. The data suggest that fascicular selectivity is strongly dependent upon the anatomy of the nerve being stimulated. Therefore, accurate representations of nerve anatomy are required to develop more accurate computer models to evaluate and optimize nerve electrode designs for neural prosthesis applications.

4 May 2018 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
EGEmily L Graczyk
Emily L Graczyk
BDBenoit P Delhaye
Benoit P Delhaye
MSMatthew A Schiefer
Matthew A Schiefer
SBSliman J Bensmaia
Sliman J Bensmaia
DTDustin J. Tyler
Dustin J. Tyler
Sensory systems adapt their sensitivity to ambient stimulation levels to improve their responsiveness to changes in stimulation. The sense of touch is also subject to adaptation, as evidenced by the desensitization produced by prolonged vibratory stimulation of the skin. Electrical stimulation of nerves elicits tactile sensations that can convey feedback for bionic limbs. In this study, we investigate whether artificial touch is also subject to adaptation, despite the fact that the peripheral mechanotransducers are bypassed. Using well-established psychophysical paradigms, we characterize the time course and magnitude of sensory adaptation caused by extended electrical stimulation of the residual somatosensory nerves in three human amputees implanted with cuff electrodes. We find that electrical stimulation of the nerve also induces perceptual adaptation that recovers after cessation of the stimulus. The time course and magnitude of electrically-induced adaptation are equivalent to their mechanically-induced counterparts. We conclude that, in natural touch, the process of mechanotransduction is not required for adaptation, and artificial touch naturally experiences adaptation-induced adjustments of the dynamic range of sensations. Further, as it does for native hands, adaptation confers to bionic hands enhanced sensitivity to changes in stimulation and thus a more natural sensory experience.