Torbjörn Thiringer

Prof. Torbjörn Thiringer

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2008 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
NUNayeem Rahmat Ullah
Nayeem Rahmat Ullah
TTTorbjörn Thiringer
Torbjörn Thiringer
DKDaniel Karlsson
Daniel Karlsson
This paper quantifies the capability of providing a short-term excess active power support of a commercial multi-megawatt variable speed wind turbine (VSWT) and generalizes the findings by considering different wind turbine (WT) physical parameters in a wider range from the example case. The paper also identifies some possible applications of it, in particular, in a hydro dominated system. To be able to quantify the system characteristic, a delay model of the studied hydro system is developed. Due to the fact that the initial power surge of a hydro turbine is opposite to that desired, the short-term extra active power support from a wind farm (WF) could be beneficial for a hydro dominated system in arresting the initial frequency fall, which corresponds to an improvement in the system temporary minimum frequency (TMF). The improvements in the TMF are calculated by using both the developed delay model and a detailed model, and the results show good agreement. It is shown that the WT under consideration can provide a 0.1 pu extra active power support for 10 s quite easily which is twice the Hydro-Quebec requirement.

10 February 2022 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
JBJohannes Buberger
Johannes Buberger
AKAnton Kersten
Anton Kersten
MKManuel Kuder
Manuel Kuder
RERichard Eckerle
Richard Eckerle
TWThomas Weyh
Thomas Weyh
TTTorbjörn Thiringer
Torbjörn Thiringer

27 January 2009 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
NUNayeem Rahmat Ullah
Nayeem Rahmat Ullah
KBKankar Bhattacharya
Kankar Bhattacharya
TTTorbjörn Thiringer
Torbjörn Thiringer
This paper examines the possibility of providing reactive power support to the grid from wind farms (WFs) as a part of the ancillary service provisions. Detailed analysis of the WF capability curve is carried out considering maximum hourly variation of wind power from the forecasted value. Different cost components are identified, and subsequently, a generalized reactive power cost model is developed for wind turbine generators that can help the independent system operator (ISO) in managing the system and the grid efficiently. Apart from the fixed cost and the cost of loss components, a new method is proposed to calculate the opportunity cost component for a WF considering hourly wind variations. The Cigre 32-bus test system is used to demonstrate a case study showing the implementation of the developed model in short-term system operations. A finding is that higher wind speed prediction errors (a site with high degree of wind fluctuations) may lead to increased payments to the WFs for this service, mainly due to the increased lost opportunity cost (LOC) component. In a demonstrated case, it is found that 2340 $/h is paid to the WF as the LOC payment only, when the wind prediction error is 0.5 per unit (p.u.), whereas 54 $/h is the expected total payment to the WF when the prediction error is 0.2 p.u. for its reactive power service.

1 November 2002 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
TPT. Petru
T. Petru
TTTorbjörn Thiringer
Torbjörn Thiringer
In this paper, the modeling of wind turbines for power system studies is investigated. Complexities of various parts of a wind turbine model, such as aerodynamic conversion, drive train, and generator representation, are analyzed. The results are verified by field measurements made on a stall-regulated fixed-speed wind turbine. The modeling focuses on deriving a representation that is suitable for use in grid simulation programs.

15 February 2008 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
STSercan Teleke
Sercan Teleke
TATarik Abdulahovic
Tarik Abdulahovic
TTTorbjörn Thiringer
Torbjörn Thiringer
JSJan Svensson
Jan Svensson
In this paper, a comparison of the dynamic performance between a conventional synchronous condenser, a superconducting synchronous condenser, and a static Var compensator (SVC) is made in a grid setup by simulating different cases that affect the performance of reactive power compensation. The results show that the SVC injects more reactive power and has a better dynamic performance during faults that cause a moderate or minor voltage drop on its terminals, such as single-phase to ground faults in weak grids. The synchronous condensers, on the other hand, bring the voltage to the nominal value quicker and show a better dynamic performance for severe faults such as three phase to ground faults in stiff grids. The superconducting synchronous condenser injects up to 45% more reactive power compared to the conventional synchronous condenser during a nearby three phase to ground fault.

1 January 1993 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
TTTorbjörn Thiringer
Torbjörn Thiringer
JLJ. Linders
J. Linders