Ying-fang Fan

Dr. Ying-fang Fan


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2018 in Advances in Structural Engineering
Verified
Journal Article
Closed access
HLHai-Yang Luan
Hai-Yang Luan
YFYing-fang Fan
Ying-fang Fan
ACAn Chen
An Chen
SZShi-Yi Zhang
Shi-Yi Zhang
This article presents an exploratory study on the flexural behavior of carbon fiber–reinforced polymer–reinforced concrete beams subjected to acidic loading effect. To this end, an artificial acid rain with a pH level of 1.5 was prepared by mixing sulfate and nitric acid solutions. Eight reinforced concrete beams with/without carbon fiber–reinforced polymer applications were constructed and conditioned using the artificial acid rain. During conditioning, bending loads were applied to the top surfaces of the beams to simulate the acidic loading action. Three carbon fiber–reinforced polymer reinforcement schemes (corrosion reinforcement, reinforcement corrosion, and cracking reinforcement) were considered. After conditioning, the length and quantity of initial cracks in the beams were recorded. A combined ultrasonic–rebound method was then adopted to measure the strength and corrosion depth of the concrete and evaluate the beams’ integrity. Next, four-point bending tests were conducted to study the beams’ flexural behavior. It can be concluded that all beams deteriorated with the increase of the corrosion time. Carbon fiber–reinforced polymer–reinforced concrete beams performed better than normal reinforced concrete beams under the acidic loading effect. The initial cracks can influence the flexural behavior of carbon fiber–reinforced polymer–reinforced concrete beams.

1 January 2019 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
YLYunyan Liu
Yunyan Liu
YFYing-fang Fan
Ying-fang Fan
In order to study the effects of initial damages, CFRP reinforcement, and chloride corrosion on the flexural behavior of prestressed concrete beams, ten prestressed concrete beams were designed and manufactured, which were preloaded with 0%, 40%, and 60% of the ultimate load to crack. Then, part of the beams were reinforced by CFRP and immersed in chloride condition for 120 days. After that, the four‐point bending tests were performed. Then, the sectional strain, deformation, flexural stiffness, flexural capacity, ductility, and the cracking characteristics were researched. The test results demonstrate that the sectional strain of PC beams still follows the plane cross section assumption after a pure bending deformation considering of the initial cracks, chloride corrosion, and CFRP reinforcement. The initial damage accelerates the chloride corrosion, resulting in the loss of initial stiffness, ductility, and cracking load, and the reduction in flexural capacity is less than 10%, and the failure modes of these beams are prone to change from concrete crushing to shear failure. In the cracking stage, the reinforcement of CFRP inhibits the bending deformation, leading to the reduction in stiffness degradation rates and the increase of cracking load, and the ultimate load increases by 12.8%∼18.7%. The reinforcement of CFRP constrains the development of cracks, increases the cracks numbers by 50%∼130%, decreases the cracking rates of beam bottoms by 52.5%, and reduces the average crack widths by 65.8% at 195 kN. It can be seen that the reinforcing effect of CFRP is more significant compared with the weakening effect of short‐term chloride corrosion and initial damage on the flexural behavior.

1 July 2018 in Journal of Laparoendoscopic & Advanced Surgical Techniques
Verified
Journal Article
Closed access
XLXingxing Liu
Xingxing Liu
JYJian Yang
Jian Yang
XLXia-Xi Li
Xia-Xi Li
NXNan Xiang
Nan Xiang
NZNing Zeng
Ning Zeng
CFChihua Fang
Chihua Fang
Introduction: To study the anatomical features and classification of the angle between the right gastroepiploic vein (RGEV) and superior mesenteric vein/portal vein (SMV/PV) and to guide the catheterization of intraportal infusion chemotherapy through RGEV and reduce surgical complications. Patients and Methods: A retrospective three-dimensional (3D) computed tomography study was undertaken on 200 consecutive subjects with or without hepatic malignant tumors with a dedicated workstation 3D-MIA (the improved MI-3DVS workstation) developed by ourselves to determine the prevalence of surgically significant angle between RGEV and SMV/PV anatomic variations and its classification. Results: The mean value of the angles between the end of RGEV and SMV/PV (AERS/P) (200 cases) was 84.2° ± 23.8 (31.4°–151.5°): 40.6° ± 92.3 (−177.9° to 178.0°) (sagittal angle), 81.7° ± 29.8 (−79.3° to 160.7°) (coronal angle), and 10.5° ± 94.3 (−178.7° to 175.8°) (horizontal angle). The mean value of the angles between the right bend of RGEV and SMV/PV (ARRS/P) (168 cases) was 104.8° ± 26.1 (20.5°–159.7°):49.3° ± 117.8 (−175.3° to 179.5°) (sagittal angle), 103.5° ± 37.7 (−178.8° to 168.9°) (coronal angle), and 12.6° ± 102.8 (−179.9° to 179.2°) (horizontal angle). The AERS/P were classified into large angle group (32 cases, 16%), middle angle group (113 cases, 56.5%), and small angle group (55 cases, 27.5%) based on angle variations and risks of catheterization. Conclusions: Precognition of the variations of AERS/P and ARRS/P before surgery is useful during chemotherapy pump catheterizing through RGEV in reduction of surgical complications by modulating the angle and direction of RGEV running into SMV/PV properly.


19 July 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
YYYushi YIN
Yushi YIN
YFYing-fang Fan
Ying-fang Fan
The single test is carried out on totally 54 concrete samples with 6 different interface-roughness conditions, as to delve into the influence of concrete surface roughness on the concrete-FRP interface. Accordingly the closed-form solution based on the compressive strength and interface roughness parameters of concrete is acquired. As the research result indicates, the extremum and extreme point exist in terms of influence of concrete surface roughness on fracture energy, the model acquired in line with the test data is appropriately applicable under the condition 0.34≤ fi ≤0.56, and such model is overall applicable under the concrete strength of 30MPa≤ f c0 ≤50MPa. The model proposed hereof in this paper is superior to the existing models, as not only the significant contribution made by concrete strength to fracture energy is considered, but the influence of concrete surface roughness on interface is highlighted.

17 October 2025 in Journal of Building Engineering
Verified
Journal Article
Closed access
XLXinjie Li
Xinjie Li
YFYing-fang Fan
Ying-fang Fan
QLQiuchao Li
Qiuchao Li
XZXiangming Zhou
Xiangming Zhou
SSSurendra P. Shah
Surendra P. Shah