Wojciech Wojciech Podraza Podraza

Mr. Wojciech Wojciech Podraza Podraza


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2026 in Materials
Verified
Journal Article
Open access
PDF file
JBJan Białasik
Jan Białasik
WPWojciech Wojciech Podraza Podraza
Wojciech Wojciech Podraza Podraza
DSDominika Samulczyk
Dominika Samulczyk
Alireza TabrizikahouAlireza Tabrizikahou
Alireza Tabrizikahou
Iron-based shape memory alloy (Fe-SMA) fibers can enhance cementitious composites through both crack bridging and thermally activated recovery stresses. Since fiber pull-out governs load transfer at the micro scale, understanding the combined effects of fiber geometry, inclination, and thermal treatment is essential. This study experimentally investigated the pull-out behavior of hooked-end Fe-SMA fibers embedded in high-performance concrete (HPC). A total of 54 ASTM C307-type briquette specimens were tested using single-hook (3D) and double-hook (4D) fibers at inclination angles of 60°, 75°, and 90° under ambient, 100 °C, and 200 °C conditions. Additional flexural, compressive, and direct tensile tests were conducted on plain HPC exposed to the same thermal regime. At ambient temperature, 4D fibers showed 50–70% higher peak pull-out forces than 3D fibers. Heating to 100 °C further increased pull-out resistance by about 6–17%, and the 4D-60-100 configuration achieved the highest performance. In contrast, exposure to 200 °C reduced pull-out resistance by about 5–12% below ambient values. Overall, a 60° inclination generally provided a better response, while 90° produced the lowest. The results confirm that moderate thermal activation combined with double-hook geometry is the most effective strategy for maximizing Fe-SMA fiber–matrix load transfer in HPC.

19 March 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
JBJan Białasik
Jan Białasik
WPWojciech Wojciech Podraza Podraza
Wojciech Wojciech Podraza Podraza
DSDominika Samulczyk
Dominika Samulczyk
Alireza TabrizikahouAlireza Tabrizikahou
Alireza Tabrizikahou
Iron-based shape memory alloy (Fe-SMA) fibers can enhance cementitious composites through both crack-bridging and thermally activated recovery stresses. Since fiber pull-out governs load transfer at the microscale, understanding the combined effects of fiber geometry, inclination, and thermal treatment is essential. This study experimentally investigated the pull-out behavior of hooked-end Fe-SMA fibers embedded in high-performance concrete (HPC). A total of 54 ASTM C307-type briquette specimens were tested using single-hook (3D) and double-hook (4D) fibers at inclination angles of 60∘, 75∘, and 90∘ under ambient, 100 ∘C, and 200 ∘C conditions. Additional flexural, compressive, and direct tensile tests were conducted on plain HPC exposed to the same thermal regime. At ambient temperature, 4D fibers showed 50–70% higher peak pull-out forces than 3D fibers. Heating to 100 ∘C further increased pull-out resistance by about 6–17%, and the 4D-60-100 configuration achieved the highest performance. In contrast, exposure to 200 ∘C reduced pull-out resistance by about 5–12% below ambient values. Overall, a 60∘ inclination generally provided the best response, while 90∘ produced the lowest. The results confirm that moderate thermal activation combined with double-hook geometry is the most effective strategy for maximizing Fe-SMA fiber–matrix load transfer in HPC.