Jan Białasik

Ms. Jan Białasik

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

21 April 2026 in Materials
Verified
Journal Article
Open access
PDF file
JBJan Białasik
Jan Białasik
WPWojciech Wojciech Podraza Podraza
Wojciech Wojciech Podraza Podraza
DSDominika Samulczyk
Dominika Samulczyk
Alireza TabrizikahouAlireza Tabrizikahou
Alireza Tabrizikahou
Iron-based shape memory alloy (Fe-SMA) fibers can enhance cementitious composites through both crack bridging and thermally activated recovery stresses. Since fiber pull-out governs load transfer at the micro scale, understanding the combined effects of fiber geometry, inclination, and thermal treatment is essential. This study experimentally investigated the pull-out behavior of hooked-end Fe-SMA fibers embedded in high-performance concrete (HPC). A total of 54 ASTM C307-type briquette specimens were tested using single-hook (3D) and double-hook (4D) fibers at inclination angles of 60°, 75°, and 90° under ambient, 100 °C, and 200 °C conditions. Additional flexural, compressive, and direct tensile tests were conducted on plain HPC exposed to the same thermal regime. At ambient temperature, 4D fibers showed 50–70% higher peak pull-out forces than 3D fibers. Heating to 100 °C further increased pull-out resistance by about 6–17%, and the 4D-60-100 configuration achieved the highest performance. In contrast, exposure to 200 °C reduced pull-out resistance by about 5–12% below ambient values. Overall, a 60° inclination generally provided a better response, while 90° produced the lowest. The results confirm that moderate thermal activation combined with double-hook geometry is the most effective strategy for maximizing Fe-SMA fiber–matrix load transfer in HPC.

19 March 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
JBJan Białasik
Jan Białasik
WPWojciech Wojciech Podraza Podraza
Wojciech Wojciech Podraza Podraza
DSDominika Samulczyk
Dominika Samulczyk
Alireza TabrizikahouAlireza Tabrizikahou
Alireza Tabrizikahou
Iron-based shape memory alloy (Fe-SMA) fibers can enhance cementitious composites through both crack-bridging and thermally activated recovery stresses. Since fiber pull-out governs load transfer at the microscale, understanding the combined effects of fiber geometry, inclination, and thermal treatment is essential. This study experimentally investigated the pull-out behavior of hooked-end Fe-SMA fibers embedded in high-performance concrete (HPC). A total of 54 ASTM C307-type briquette specimens were tested using single-hook (3D) and double-hook (4D) fibers at inclination angles of 60∘, 75∘, and 90∘ under ambient, 100 ∘C, and 200 ∘C conditions. Additional flexural, compressive, and direct tensile tests were conducted on plain HPC exposed to the same thermal regime. At ambient temperature, 4D fibers showed 50–70% higher peak pull-out forces than 3D fibers. Heating to 100 ∘C further increased pull-out resistance by about 6–17%, and the 4D-60-100 configuration achieved the highest performance. In contrast, exposure to 200 ∘C reduced pull-out resistance by about 5–12% below ambient values. Overall, a 60∘ inclination generally provided the best response, while 90∘ produced the lowest. The results confirm that moderate thermal activation combined with double-hook geometry is the most effective strategy for maximizing Fe-SMA fiber–matrix load transfer in HPC.

21 May 2026 in Materials
Verified
Journal Article
Open access
PDF file
Alireza TabrizikahouAlireza Tabrizikahou
Alireza Tabrizikahou
JBJan Białasik
Jan Białasik
KNKarol Nowak
Karol Nowak
KLKrzysztof Chryzostom Lehmann
Krzysztof Chryzostom Lehmann
GTGrzegorz Trzmiel
Grzegorz Trzmiel
Arkadiusz DobrzyckiArkadiusz Dobrzycki
Arkadiusz Dobrzycki
Iron-based shape memory alloy (Fe–SMA) rebars can generate internal prestress in cement-based members after restrained thermal activation; however, the temperature actually reached by embedded rebars in cracked UHPFRC is difficult to infer from exposed bar segments. This study investigates electrical resistance activation of 4% prestrained Fe–SMA rebars embedded in pre-cracked UHPFRC beams and clarifies the activation-control problem by combining thermocouple measurements with a calibrated two-dimensional electro-thermal simulator. Twelve beams (150 × 150 × 600 mm) containing either Dramix 3D or Dramix 4D hooked steel fibers were first loaded in three-point bending to a mid-span displacement of 4 mm. The 4D series reached a 9.47% higher average pre-cracking load, confirming that fiber geometry modified the cracked state before heating. During activation, the exposed rebar segment reached 200 °C after approximately 77 s, whereas the embedded working segment reached the same target only after approximately 213 s; at that moment, the exposed segment was already close to 350 °C. The calibrated simulator reproduced the target activation time with an error of approximately 3 s and visualized the localized heat transfer from Fe–SMA to UHPFRC. The results demonstrate that activation control based only on exposed-bar temperature may cause under-activation of the embedded reinforcement, and that direct internal temperature monitoring is required for reliable Fe–SMA activation in cracked UHPFRC members.

26 February 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
TJTomasz Jankowiak
Tomasz Jankowiak
JBJan Białasik
Jan Białasik
MŁMagdalena Łasecka-Plura
Magdalena Łasecka-Plura
Mieczysław KUCZMAMieczysław KUCZMA
Mieczysław KUCZMA
This study investigates the mechanical response of bifacial glass-glass photovoltaic modules subjected to snow-type loading, with a particular focus on the influence of silicon cell spacing on global deformation and local stress distributions in the silicon layer. Five computational finite element models were developed which explicitly represent all laminate layers and discrete cell layout. The numerical results are interpreted within the framework of partial interaction and shear transfer between the glass plies, and are validated against previously obtained home conducted experimental observations. The results demonstrate that silicon cell layout has a pronounced effect on local tensile stresses in silicon cells and on the curvature distribution within the laminate, while its influence on the global kinematic response is less critical. The numerical analysis indicates that the relative displacements between the glass layers resulting from the flexibility of the adhesive bond play a critical role.

18 April 2026 in Materials
Verified
Journal Article
Open access
PDF file
TJTomasz Jankowiak
Tomasz Jankowiak
JBJan Białasik
Jan Białasik
MŁMagdalena Łasecka-Plura
Magdalena Łasecka-Plura
Mieczysław KUCZMAMieczysław KUCZMA
Mieczysław KUCZMA
This study investigates the mechanical response of bifacial glass–glass photovoltaic modules subjected to snow-type loading, with a particular focus on the influence of silicon cell spacing on global deformation and local stress distributions in the silicon cell layer and the adhesive layer. Five computational finite element models were developed which explicitly represent all laminate layers and discrete cell layout. The numerical results are interpreted within the framework of partial interaction and shear transfer between the glass plies and are validated against previously obtained home conducted experimental observations. The results demonstrate that a silicon cell layout has a pronounced effect on local tensile stresses in silicon cells and on the curvature distribution within the laminate, while its influence on the global kinematic response is less critical. The numerical analysis indicates that the relative displacements between the glass layers resulting from the flexibility of the adhesive bond play a critical role.