Awutsadaporn Katheng

Prof. Dr. Awutsadaporn Katheng

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2024 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
AKAwutsadaporn Katheng
Awutsadaporn Katheng
WPWisarut Prawatvatchara
Wisarut Prawatvatchara
WTWatcharapong Tonprasong
Watcharapong Tonprasong
SNSahaprom Namano
Sahaprom Namano
PKPaweena Kongkon
Paweena Kongkon
Objectives This in vitro study investigated the effects of different postrinsing times and methods on the surface roughness, surface hardness, and degree of polymerization of materials manufactured via stereolithography (SLA). Materials and Methods A total of 288 disk-shaped specimens were manufactured using an SLA three-dimensional (3D) printer. The specimens were randomly divided into nine groups (n = 32) based on rinsing times and methods. The groups were categorized into three rinsing methods: automated, ultrasonic, and hand washing, with rinsing times of 5, 10, and 15 minutes using a 99% isopropanol alcohol as a solvent. Linear roughness (Ra) and area roughness (Sa) were measured using a 3D confocal laser microscopy; the roughness morphology was evaluated by using scanning electron microscopy. Vickers hardness (VHN) tests were performed using a Vickers microhardness tester. Fourier-transform infrared spectrometry was used to determine the degree of conversion of treated specimens. Statistical Analysis Data were statistically analyzed using two-way analysis of variance. The post hoc Tukey tests were conducted to compare the differences between groups (p < 0.05). Results The choice of the rinsing time and method affected the surface properties of the SLA photopolymer resin. The 15 minutes of ultrasonic method exhibited the highest Ra scores (0.86 ± 0.1 µm), while the 15 minutes of automated method presented the highest Sa scores (1.77 ± 0.35 µm). For the VHN test, the 15 minutes of ultrasonic method displayed the highest VHN score (18.26 ± 1.03 kgf/mm2). For the degree of polymerization, the 15 minutes of automated method was initially identified as the most effective (87.22 ± 6.80). Conclusion To facilitate the overall surface roughness, surface hardness, and degree of polymerization, the optimal choice of postprocessing rinsing time and method for achieving a clear photopolymer resin was determined to be the ultrasonic method with a rinsing time of 15 minutes. Article published online: 17 May 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

1 January 2022 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
AKAwutsadaporn Katheng
Awutsadaporn Katheng
MKManabu Kanazawa
Manabu Kanazawa
YKYuriko Komagamine
Yuriko Komagamine
MIMaiko Iwaki
Maiko Iwaki
SNSahaprom Namano
Sahaprom Namano
SMShunsuke Minakuchi
Shunsuke Minakuchi
Katheng A, et al. J Adv Prosthodont. 2022 Feb;14(1):45-55. https://doi.org/10.4047/jap.2022.14.1.45

10 December 2024 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
NWNapatsorn Wechkunanukul
Napatsorn Wechkunanukul
KKKornuma Klomjit
Kornuma Klomjit
TKThawanrat Kumtun
Thawanrat Kumtun
PJPongsiri Jaikumpun
Pongsiri Jaikumpun
SKSantiphab Kengtanyakich
Santiphab Kengtanyakich
AKAwutsadaporn Katheng
Awutsadaporn Katheng
Objective This study compared the flexural strength, surface hardness, and surface roughness of conventional, milled, and three-dimensional (3D)-printed provisional restorations. Materials and Methods Bar-shaped polymethyl methacrylate (PMMA) specimens (25 × 2 × 2 mm3) and disc-shaped specimens (9 × 2 mm2) were fabricated using three different techniques (n = 10/group): conventional (SR Ivocron C&B, Ivoclar Vivadent, Schaan, Liechtenstein), milling (Aidite Temp PMMA Blocks, Aidite, Qinhuangdao, China), and 3D printing (Asiga DentaTOOTH, Asiga, Sydney, Australia). Flexural strength was evaluated using a universal testing machine until fracture occurred. Vickers hardness and surface roughness tests were performed on the disc-shaped specimens using a micro-Vickers hardness tester and atomic force microscopy, respectively. Statistical Analysis Data were statistically analyzed using one-way ANOVA. The post hoc Tukey's honest significant difference was conducted to compare the differences value between groups (p < 0.05). Results The milled computer-aided design/computer-aided manufacturing (CAD/CAM) provisional restorative material exhibited a significantly higher flexural strength (125.16 ± 6.83 MPa) compared with both the traditional (109.74 ± 14.14 MPa) and 3D-printed (71.09 ± 9.09 MPa) materials (p < 0.05). The conventional material had a higher Vickers hardness (19.27 ± 0.41 kgf/mm2) compared with the milled (18.53 ± 0.32 kgf/mm2) and 3D-printed (17.80 ± 1.85 kgf/mm2) materials, though the difference was statistically significant only between the conventional and 3D-printed groups. The surface roughness of the milled CAD/CAM material (8.80 ± 2.70 nm) was significantly lower than that of the 3D-printed material (24.27 ± 9.82 nm) (p < 0.05). Conclusion The provisional restorations fabricated using milled PMMA technology provide adequate flexural strength, surface hardness, and low surface roughness, offering a viable alternative for creating provisional restorations. Article published online: 10 December 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

1 January 2025 in International Journal of Dentistry
Verified
Journal Article
Open access
WPWisarut Prawatvatchara
Wisarut Prawatvatchara
AKAwutsadaporn Katheng
Awutsadaporn Katheng
PKPaweena Kongkon
Paweena Kongkon
SSSantisuk Sombun
Santisuk Sombun
PSPiangkwan Saiprasert
Piangkwan Saiprasert
NJNawaporn Jittapiromsak
Nawaporn Jittapiromsak
Background: The repairability of provisional restorative materials affects the duration of the provisional treatment phase. This study evaluated the effects of various silane (Si)‐containing universal adhesives on the shear bond strength (SBS) of aged three‐dimensional (3D)‐printed provisional restorative materials. Methods: Seventy SBS specimens (20 mm diameter × 15 mm height) and 10 specimens for energy‐dispersive X‐ray (EDX) analysis (5 mm diameter × 3 mm height) were fabricated. All SBS specimens underwent thermocycling in artificial saliva at 5– 55 °C, with 60 s dwell time, using a thermocycler (SD Mechatronik, Germany). The SBS specimens were randomly divided into seven groups ( n = 10 per group) on the basis of the repair method: C group (control), S group (Single Bond 2), SU group (Scotchbond Universal), SUP group (Scotchbond Universal Plus), CUQ group (CLEARFIL TRI‐S BOND Universal Quick), GPB group (G‐Premio Bond), and Si + S group (Silane Ultradent + Single Bond 2). The SBS test was performed using a universal testing machine (Instron, ElectroPulsTM E1000, England). Failure modes were analyzed for all debonding surfaces. Data was analyzed using one‐way analysis of variance (ANOVA) and Tukey’s HSD test ( p < 0.05). Results: The highest SBS was observed in the Si + S group (21.06 ± 1.47 MPa), followed by SUP (19.43 ± 1.45 MPa), CUQ (16.14 ± 1.54 MPa), SU (15.71 ± 1.40 MPa), GPB (12.93 ± 1.56 MPa), S (12.59 ± 1.64 MPa), and C (8.20 ± 1.49 MPa). However, no significant difference in the SBS was observed between the Si + S and SUP groups. Additionally, there was no significant difference in SBS between S and GPB. Failure mode analysis revealed a correlation between the type of failure pattern and the SBS results. Conclusion: The SUP group, a silane‐containing universal adhesive, demonstrated high SBS comparable with the separate application of Si, suggesting it as a viable alternative in provisional material repair.

1 January 2025 in Case Reports in Dentistry
Verified
Journal Article
Open access
PKPaweena Kongkon
Paweena Kongkon
AKAwutsadaporn Katheng
Awutsadaporn Katheng
PSPiangkwan Saiprasert
Piangkwan Saiprasert
PAPokpong Amornvit
Pokpong Amornvit
This study introduces the Tako tray, a modified individual tray designed for the closed‐mouth impression technique, and demonstrates its integration with Ivotion CAD/CAM technology to enhance complete denture fabrication by combining conventional and digital workflows. A clinical case was conducted using the Tako tray to facilitate accurate impression‐taking and jaw relation recording. Primary impressions were taken, followed by the fabrication of the Tako tray. The closed‐mouth definitive impression was recorded in centric relation, simultaneously capturing functional and jaw relation records. The collected data were digitized and processed using the Ivotion CAD/CAM system for virtual denture design and milling. This approach streamlined the fabrication process and minimized patient visits. The integration of the Tako tray with the Ivotion workflow reduced clinical appointments to three, while improving occlusal rim retention and ensuring accurate jaw relation recording. The final dentures demonstrated precise fit, functional efficiency, and satisfactory esthetics, with the patient reporting high satisfaction. The combination of the Tako tray and digital technology optimized denture fabrication by increasing efficiency, reducing patient chair time, and achieving predictable, high‐quality outcomes. Clinically, the Tako tray simplifies the closed‐mouth impression technique, making digital workflows more accessible for complete denture cases while enhancing patient comfort and improving prosthetic results.

29 April 2026 in Polymers
Verified
Journal Article
Open access
PDF file
TPTunyaporn Parmornsupornvichit
Tunyaporn Parmornsupornvichit
AKAwutsadaporn Katheng
Awutsadaporn Katheng
WTWatcharapong Tonprasong
Watcharapong Tonprasong
PKPaweena Kongkon
Paweena Kongkon
This study investigated the effect of post-silanization processing on the surface chemistry and dispersion stability of 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) nanoparticles intended for the reinforcement of dental photopolymer resins. The nanoparticles were silanized using 3-Methacryloxypropyltrimethoxysilane and subjected to different post-treatment protocols, including control, drying, and centrifugation. Particle morphology was examined using field-emission scanning electron microscopy (FE-SEM) and transmission electron microscopy (TEM). Dispersion behavior was analyzed by dynamic light scattering (DLS) and zeta potential measurements, performed in triplicate (n = 3), while surface chemical modifications were evaluated using Fourier transform infrared spectroscopy (FT-IR) and X-ray photoelectron spectroscopy (XPS). Post-silanization processing significantly influenced nanoparticle surface chemistry and dispersion stability. Centrifugation promoted the formation of Si–O–Zr and Si–O–Si linkages, reduced loosely adsorbed silane species, decreased particle agglomeration, and increased zeta potential magnitude, resulting in a more uniform hydrodynamic size distribution compared to the dried group (Z-average ≈ 814 nm, PDI ≈ 0.44). These findings suggest that post-silanization centrifugation acts as an interfacial selection mechanism that distinguishes covalently grafted silane from weakly adsorbed species. Within the limitations of this in vitro study, further investigations under varied conditions are required to confirm broader applicability.