Pokpong Amornvit

Dr. Pokpong Amornvit

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
PAPokpong Amornvit
Pokpong Amornvit
Dinesh RokayaDinesh Rokaya
Dinesh Rokaya
SSSasiwimol Sanohkan
Sasiwimol Sanohkan
There have been various developments in intraoral 3D scanning technology. This study is aimed at investigating the accuracy of 10 scanners developed from 2015 to 2020. A maxillary dental model with reference points was printed from Form 2 (FormLabs, Somerville, MA, USA). The model was scanned 5 times with each intraoral scanner (IOS); Trios 3 (normal and high‐resolution mode); Trios 4 (normal and high‐resolution mode) (3Shape Trios A/S, Copenhagen, Denmark); iTero Element, iTero 2, and iTero 5D Element (Align Technologies, San Jose, California, USA); Dental Wings (Dental Wings, Montreal QC, Canada); Panda 2 (Pengtum Technologies, Shanghai, China); Medit i500 (Medit Corp. Seoul, South Korea); Planmeca Emerald™ (Planmeca, Helsinki, Finland); and Aoralscan (Shining 3D Tech. Co., Ltd., Hangzhou, China). After the scan, the 3D scanned stereolithography files were created. The various distances were measured five times in X, Y, Z, and XY axes of various scans and with a vernier caliper (control) and from the Rhinoceros software. The data were analyzed using SPSS 18. Test for the normality of the various measurement data were done using Kolmogorov‐Smirnov test. The trueness and precision of the measurements were compared among the various scans using the Kruskal‐Wallis test. The significance was considered at P < 0.05. The trueness of the intraoral scans was analyzed by comparing the measurements from the control. Precision was tested through the measurements of repeated scans. It showed that more the distance is less the accuracy for all scanners. In all studied scanners, the trueness varied but precision was favorably similar. Diagonal scanning showed less accuracy for all the scanners. Hence, when scanning the full arch, the dentist needs to take more caution and good scan pattern. Trios series showed the best scan results compared to other scanners.

PAPokpong Amornvit
Pokpong Amornvit
SSSasiwimol Sanohkan
Sasiwimol Sanohkan
Face scanners promise wide applications in medicine and dentistry, including facial recognition, capturing facial emotions, facial cosmetic planning and surgery, and maxillofacial rehabilitation. Higher accuracy improves the quality of the data recorded from the face scanner, which ultimately, will improve the outcome. Although there are various face scanners available on the market, there is no evidence of a suitable face scanner for practical applications. The aim of this in vitro study was to analyze the face scans obtained from four scanners; EinScan Pro (EP), EinScan Pro 2X Plus (EP+) (Shining 3D Tech. Co., Ltd. Hangzhou, China), iPhone X (IPX) (Apple Store, Cupertino, CA, USA), and Planmeca ProMax 3D Mid (PM) (Planmeca USA, Inc. IL, USA), and to compare scans obtained from various scanners with the control (measured from Vernier caliper). This should help to identify the appropriate scanner for face scanning. A master face model was created and printed from polylactic acid using the resolution of 200 microns on x, y, and z axes and designed in Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA). The face models were 3D scanned with four scanners, five times, according to the manufacturer’s recommendations; EinScan Pro (Shining 3D Tech. Co., Ltd. Hangzhou, China), EinScan Pro 2X Plus (Shining 3D Tech. Co., Ltd. Hangzhou, China) using Shining Software, iPhone X (Apple Store, Cupertino, CA, USA) using Bellus3D Face Application (Bellus3D, version 1.6.2, Bellus3D, Inc. Campbell, CA, USA), and Planmeca ProMax 3D Mid (PM) (Planmeca USA, Inc. IL, USA). Scan data files were saved as stereolithography (STL) files for the measurements. From the STL files, digital face models are created in the computer using Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA). Various measurements were measured five times from the reference points in three axes (x, y, and z) using a digital Vernier caliper (VC) (Mitutoyo 150 mm Digital Caliper, Mitutoyo Co., Kanagawa, Japan), and the mean was calculated, which was used as the control. Measurements were measured on the digital face models of EP, EP+, IPX, and PM using Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA). The descriptive statistics were done from SPSS version 20 (IBM Company, Chicago, USA). One-way ANOVA with post hoc using Scheffe was done to analyze the differences between the control and the scans (EP, EP+, IPX, and PM). The significance level was set at p = 0.05. EP+ showed the highest accuracy. EP showed medium accuracy and some lesser accuracy (accurate until 10 mm of length), but IPX and PM showed the least accuracy. EP+ showed accuracy in measuring the 2 mm of depth (diameter 6 mm). All other scanners (EP, IPX, and PM) showed less accuracy in measuring depth. Finally, the accuracy of an optical scan is dependent on the technology used by each scanner. It is recommended to use EP+ for face scanning.

30 October 2021 in Polymers
Verified
Journal Article
Open access
PDF file
SSSimone Shah
Simone Shah
DGDhanraj Ganapathy
Dhanraj Ganapathy
DVDeepak Nallaswamy Veeraiyan
Deepak Nallaswamy Veeraiyan
PAPadma Ariga
Padma Ariga
Artak HeboyanArtak Heboyan
Artak Heboyan
VSViritpon Srimaneepong
Viritpon Srimaneepong
Recently, polyetheretherketone (PEEK) has been introduced to the dental market as a high-performance and chemically inert biomaterial. This study aimed to compare the wear resistance, abrasiveness, color stability, and displacement resistance of zirconia and PEEK milled crowns. An ideal tooth preparation of a first maxillary molar was done and scanned by an intraoral scanner to make a digital model. Then, the prosthetic crown was digitally designed on the CAD software, and the STL file was milled in zirconia (CaroZiir S, Carol Zircolite Pvt. Ltd., Gujarat, India) and PEEK (BioHpp, Bredent GmbH, Senden, Germany) crowns using five-axis CNC milling machines. The wear resistance, color stability, and displacement resistance of the milled monolithic zirconia with unfilled PEEK crowns using a chewing simulator with thermocyclic aging (120,000 cycles) were compared. The antagonist wear, material wear, color stability, and displacement were evaluated and compared among the groups using the Wilcoxon–Mann–Whitney U-test. Zirconia was shown to be three times more abrasive than PEEK (p value < 0.05). Zirconia had twice the wear resistance of PEEK (p value < 0.05). Zirconia was more color stable than PEEK (p value < 0.05). PEEK had more displacement resistance than zirconia (p value < 0.05). PEEK offers minimal abrasion, better stress modulation through plastic deformation, and good color stability, which make it a promising alternative to zirconia crown.

1 January 2013 in Journal of Clinical and Diagnostic Research
Verified
Journal Article
Open access
PAPokpong Amornvit
Pokpong Amornvit
Finger amputation may result from congenital cause, trauma, infection and tumours. The finger amputation may be rehabilitated with dental implant-retained finger prosthesis. The success of implant-retained finger prosthesis is determined by the implant loading. The type of the force is a determining factor in implant loading. To evaluate stress distributions in finger bone when the loading force is applied along the long axis of the implant using finite element analysis. The finite element models were created. The finger bone model containing cortical bone and cancellous bone was constructed by using radiograph. Astra Tech Osseo Speed bone level implant of 4.5 mm diameter and 14 mm length was selected. The force was applied to the top of the abutment along the long axis of the implant. Finite element analysis indicated that the maximum stress was located at the head of abutment screw. The minimum stress was located in the apical third of the implant fixture. The weakest point was calculated by safety factor which is located in the spongy bone at apical third of the fixtures. Finally, 4.9 times yield stress of spongy bone was needed for the deformation of the spongy bone. Finite element study showed that when the force was applied along the long axis of the implant, the maximum stress was located around the neck of the implant and the cortex bone received more stress than cancellous bone. So, to achieve long term success, the designers of implant systems must confront biomaterial and biomechanical problems including in vivo forces on implants, load transmission to the interface and interfacial tissue response.

14 February 2020 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
PAPokpong Amornvit
Pokpong Amornvit
SSSasiwimol Sanohkan
Sasiwimol Sanohkan
CPChaimongkon Peampring
Chaimongkon Peampring
There are various scanners available in dental practice with various accuracies. The aim of this study was to compare the 3D capturing accuracy of scans obtained from Trios 3 and Dental Wings scanner. A reference mandibular model was printed from FormLab with reference points in three axes (X, Y, and XY and Z). The printed model was scanned 5 times with 3 scans: normal scan by Trios 3 (Trios 3A), high-resolution scan by Trios 3 (Trios 3B), and normal scan by Dental Wings. After scan, the stereolithography (stl) files were generated. Then, the measurements were made from the computer software using Rhinoceros 3D (Rhino, Robert McNeel & Associates for Windows, Washington DC, USA). The measurements made with digital caliper were taken as control. Statistical analysis was done using one-way ANOVA with post hoc using Sheffe (P<0.01). Trios 3 presented higher accuracy than Dental Wings and high resolution showed better results. The Dental Wings showed less accuracy at the measurements >50 mm of length and >30 mm in width. There was no significant difference (P>0.05) of control with the Trios 3A and Trios 3B. Similarly, for the measurements in Z-axis, there was no significant difference of control with each scan (Trios 3A, Trios 3B, and Dental Wings). Accuracy of the scan is affected by the length of the scanning area and scanning pattern. It is less recommended to Dental Wings scan >3-unit prosthesis and that crosses the midline.

20 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
PTPisut Thangwarawut
Pisut Thangwarawut
PAPokpong Amornvit
Pokpong Amornvit
Dinesh RokayaDinesh Rokaya
Dinesh Rokaya
SKSirichai Kiattavorncharoen
Sirichai Kiattavorncharoen
This research aimed to compare the accuracy of dental implant placement among three types of surgical guide: metal sleeve with key handle (Nobel guide, Nobel Biocare, Göteborg, Sweden), metal sleeve without key handle, and non-sleeve without key handle (Dentium full guide kit, Dentium Co., Seoul, Korea) when placing the implant in different bone inclinations. A total of 72 polyurethane bone models were fabricated in different inclinations (0°, 45°, and 60°). The dental implants were placed in bone models following the company’s recommendations. After dental implants were installed, the digital scans were done by an extraoral scanner. The deviations of the dental implant position were evaluated by superimposition between post-implant placement and reference model by using GOM inspect software. The deviation measurement was shown in 5 parameters: angular deviation, 3D deviation at the crest, 3D deviation at the apex, lateral linear deviation, and vertical linear deviation. The data were analyzed using One-way ANOVA and post-hoc tests at a significance level of 0.05. The accuracy of the dental implant position was not significantly influenced by the difference in the surgical guide system (p > 0.05). There were significant differences between placed and planned implant positions in the different inclinations of the bone. A significant difference was found in all parameters of 0° and 60° bone inclinations (p < 0.05). At 0° and 45°, angulated bone showed significant differences except in 3D deviation at the apex. Between 45° and 60° were significant differences only in angular deviation. Within the limitations of this study, the accuracy of implant placement among three types of surgical guides (Non-sleeve without key handle, Metal sleeve without key handle, and Metal sleeve with key handle) from two companies (Dentium and Nobel Biocare) was similar. Hence, the operators can choose the surgical guide system according to their preference. The inclination of bone can influence the angulation of dental implants.