Ahmed Asker

Dr. Ahmed Asker

Mechatronics and Robotics, Egypt-Japan university of Science and technology, Burj al ‘Arab, Al Iskandarīyah, Egypt
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2017 in Advanced Robotics
Verified
Journal Article
Closed access
AAAhmed Asker
Ahmed Asker
SASamy F. M. Assal
Samy F. M. Assal
MDMing Ding
Ming Ding
JTJun Takamatsu
Jun Takamatsu
TOTsukasa Ogasawara
Tsukasa Ogasawara
AMA. M. Mohamed
A. M. Mohamed
Designing a sit-to-stand (STS) assistive system that mimics the normal transfer is important for improving the quality of life for elderly and mobility impaired people while reducing the burden on the caregivers. This paper presents a robotic-based STS assisting system that can provide assistance at the shoulder and the buttock. The minimum jerk criterion is used to model the natural STS motion. Anthropometry and characteristics of the natural STS motion are used to increase the simplicity and applicability of the STS motion model. This model can generate the shoulder and hip trajectories during STS. This enables the system to provide assistance either at the upper trunk or at the upper trunk and the hip simultaneously without inducing abnormal motion kinematics. The assisting system is used to assist subjects with different heights using the trajectories generated by the proposed motion model. In addition, the proposed trajectory is compared to the one that is resulted from a commercial lifter. The results show that the proposed method can accurately replicate the natural STS motion and results in a lower interaction force. Moreover, the subjects are more satisfied when they are assisted using the proposed method as indicated by the results of the post-experiment questionnaire.

1 July 2014
Verified
Conference Paper
Closed access
AAAhmed Asker
Ahmed Asker
OSOmar Salah
Omar Salah
AEAhmed M. R. Fath El-Bab
Ahmed M. R. Fath El-Bab
ARAhmed A. Ramadan
Ahmed A. Ramadan
SASamy M. F. Assal
Samy M. F. Assal
AAAhmed Abo-Ismail
Ahmed Abo-Ismail
Nowadays parallel manipulators are used widely in bioengineering applications; this leads to many exciting expectations as well as challenges. The kinematic analysis of parallel manipulators with their differential kinematics yielding the Jacobian in a closed form is not a trivial task. In this paper a parallel manipulator based mobility assistive device called EJADII is analyzed to determine forward kinematics, inverse kinematics and closed-form Jacobian. An Adaptive Neuro-Fuzzy Inference System (ANFIS) is trained to estimate the Jacobian. This system would be useful when determination of the Jacobian in a closed-form is difficult to determine. The human motion during sit to stand captured by VICON experiment is used with two assisting scenarios to train and verify this system. Computer simulations show relatively good results of the proposed system.

12 July 2021
Verified
Conference Paper
Closed access
AAAhmed Asker
Ahmed Asker
SXShengquan Xie
Shengquan Xie
ADAbbas A. Dehghani-Sanij
Abbas A. Dehghani-Sanij
The ability to follow a normal anatomical motion is one of the fundamental design requirements of wearable exoskeleton. Human knee motion is a combination of sliding and rolling actions, which can not be replicated by a simple kinematic pair with a fixed rotation axis. In this paper, a polycentric robotic knee exoskeleton is designed based on the 5-bar mechanism (5- BM) to reproduce knee motion. The Genetic Algorithm finds the optimum parameters of the 5-BM by minimizing a weighted cost function which consists of the average Joint Force Index (JFI) and the misalignment between the centre of rotation of the exoskeleton and the user’s knee. An average and maximum ICR error of 0. 16mm and 0. 43mm is obtained by the optimized 5-BM. It yielded an average actuation toque of 7. 33N.m and JFI of 4.88 compared to 217. 73N.m and 6.04 obtained by the widely used 4-BM.


1 October 2015
Verified
Conference Paper
Closed access
AAAhmed Asker
Ahmed Asker
SASamy F. M. Assal
Samy F. M. Assal
AMA. M. Mohamed
A. M. Mohamed
Dynamic simulation of manipulators interacting directly with human is crucial for predicating their performance before the actual use. This paper describes the dynamic analysis and simulation of a novel multi-function mobility assistive device for elderly. The device is designed to help patients who suffer from degradation of the lower limbs muscular strength. Rather than one function device, the proposed device is intended to assist in different lower limb activities, namely, sit to stand and walking activities as well as transfer paralyzed patients from bed to wheelchair and help them stand in upright position to improve blood circulation. The device is based on a non-conventional structure of a 3-RPR planer parallel manipulator which has high rigidity due to the parallel structure. It has some interesting kinematic advantages that facilitate structure and control design. Dynamic model for the assistive manipulator is derived using the first type of Lagrange's equations. A PD-computed torque controller is tuned using genetic algorithm. Simulation results prove high performance of the proposed device in terms of the low tracking error and the proper actuator force.

1 November 2013
Verified
Conference Paper
Closed access
OSOmar Salah
Omar Salah
AAAhmed Asker
Ahmed Asker
AEAhmed M. R. Fath El-Bab
Ahmed M. R. Fath El-Bab
SASamy M. F. Assal
Samy M. F. Assal
ARAhmed A. Ramadan
Ahmed A. Ramadan
AAAhmed Abo-Ismail
Ahmed Abo-Ismail
This paper describes a novel mobility assistive device under development in the Egypt-Japan University of Science and Technology (E-JUST). The proposed system can help patients who do not have enough physical strength on the lower limbs during sit to stand due to aging, diseases such as polymyositis and myopathy, and joint replacement surgery complications. It can follow the natural pattern of human motion during sit to stand providing assistance force under the shoulder. The overall device is compact and employees a parallel mechanism which provide more stiffness. Several experiments were carried out in a VICON room to calculate the human motion posture while sit to stand motion in addition estimate the trajectory of the end effector during assisting. Computer simulation was built to verify the performance of the proposed system with the reference trajectory.