1 November 2019 in Energy Conversion and Management
3 April 2014 in Key Engineering Materials
A new strain gauge based on graphene piezoresistivity was fabricated by a novel low cost technique which suits mass production of micro piezoresistor sensors. The strain gauge consists of a monolayer graphene film made by chemical vapor deposition on a copper foil surface, and transferred to Si/SiO2 surface by using a polymethyl-methacrylate (PMMA) assisted transfer method. The film is shaped by laser machine to work as a conductive-piezoresistive material between two deposited electrical silver electrodes. This method of fabrication provides a high productivity due to the homogeneous distribution of the graphene monolayer all over the Si/SiO2 surface. The experimentally measured gauge factor of graphene based device is 255, which promises a new strain gauge sensor of high sensitivity.
15 March 2022 in The International Journal of Advanced Manufacturing Technology
Microfluidic devices are a rising technology to automatize chemical and biological operations. In this context, laser ablation has significant potential for polymer-based microfluidic platforms’ fast and economical manufacturing. Nevertheless, the manufacturing of epoxy-based microfluidic chips is considered highly cost full due to the demand for cleanroom facilities that utilize expensive equipment and lengthy processes. Therefore, this study targeted investigating the feasibility of epoxy resins to be fabricated as a lab-on-chip using carbon dioxide laser ablation. The chemical structural properties and thermal stability of the plain epoxy resins were characterized by Fourier transform infrared spectral analysis (FT-IR) and thermogravimetric analysis (TGA). Moreover, a specific migration test was performed to quantify potential migrants by gas chromatography coupled to mass spectrometry (GC–MS) to prove that the cured epoxy resin would not release unreacted monomers to the biological solution test, which caused inhibition of the sensitive biological reactions. By investigating the impact of this process on microchannels’ dimensions and quality, a laser technique using CO2 laser was used in vector mode to engrave into a transparent epoxy resin chip. The resulting microchannels were characterized using 3D laser microscopy. The outcomes of this study showed considerable potential for laser ablation in machining the epoxy-based chips, whereas the microchannels machined by laser processing at an input power of 1.8 W and scanning speed of 5 mm/s have an aspect ratio of about 1.19 and a reasonable surface roughness (Ra) of ~ 15 µm. Meanwhile, the bulge height was 0.027 µm with no clogging, and HAZ was ~ 18 µm. This study validated the feasibility of quick and cost-effective CO2 laser microfabrication to develop epoxy resin-based microfluidic chips without the need for cleanroom facilities that require expensive equipment and lengthy process.
14 February 2012 in Journal of Microelectromechanical Systems
Compliance detection becomes very essential in minimally invasive surgery (MIS). It can help in detection of cancerous lumps and/or for deciding on tissue healthiness. In this paper, a micromachined piezoresistive tactile sensor, with two serpentine springs and 500-μm cubic mesas, has been designed for detecting the compliance of soft tissue independent of the applied distance between the sensor and the tissue. The measuring range of the sensor is chosen to be associated with the soft-tissue properties. The sensor parameters are optimized to give high sensitivity and linearity of the sensor output. The design is simulated using ANSYS for checking the sensor performance. Then, the sensor is fabricated and tested by three types of specimens, namely, specimen chips with known stiffness, silicone rubber specimens, and chicken organ specimens (leg and heart). For the specimen chips and silicone rubber specimens, the sensor distinguished between different stiffnesses independent of the applied displacement in the range of 50-200 μm. The sensor measured Young's modulus up to 808 kPa with an average error of ±7.25%. For the chicken leg and heart, the sensor distinguished between them under the applied displacement from 100 to 200 μm, and they were calculated as 12 ±1 kPa and 81 ±8 kPa, respectively.