Marcelo Alessandro Rigotti

Dr. Marcelo Alessandro Rigotti

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2015 in Revista Latino-Americana de Enfermagem
Verified
Journal Article
Open access
PDF file
AFAdriano Ferreira
Adriano Ferreira
Denise AndradeDenise Andrade
Denise Andrade
MRMarcelo Alessandro Rigotti
Marcelo Alessandro Rigotti
MAMargarete Teresa Gottardo de Almeida
Margarete Teresa Gottardo de Almeida
OGOdanir Garcia Guerra
Odanir Garcia Guerra
AJAires Garcia dos Santos Junior
Aires Garcia dos Santos Junior
OBJECTIVE: to assess the efficiency of cleaning/disinfection of surfaces of an Intensive Care Unit.METHOD: descriptive-exploratory study with quantitative approach conducted over the course of four weeks. Visual inspection, bioluminescence adenosine triphosphate and microbiological indicators were used to indicate cleanliness/disinfection. Five surfaces (bed rails, bedside tables, infusion pumps, nurses' counter, and medical prescription table) were assessed before and after the use of rubbing alcohol at 70% (w/v), totaling 160 samples for each method. Non-parametric tests were used considering statistically significant differences at p<0.05.RESULTS: after the cleaning/disinfection process, 87.5, 79.4 and 87.5% of the surfaces were considered clean using the visual inspection, bioluminescence adenosine triphosphate and microbiological analyses, respectively. A statistically significant decrease was observed in the disapproval rates after the cleaning process considering the three assessment methods; the visual inspection was the least reliable.CONCLUSION: the cleaning/disinfection method was efficient in reducing microbial load and organic matter of surfaces, however, these findings require further study to clarify aspects related to the efficiency of friction, its frequency, and whether or not there is association with other inputs to achieve improved results of the cleaning/disinfection process.

1 June 2012 in Revista da Escola de Enfermagem da USP
Verified
Journal Article
Open access
PDF file
AFAdriano Ferreira
Adriano Ferreira
BSBruna Machado Vieira de Souza
Bruna Machado Vieira de Souza
MRMarcelo Alessandro Rigotti
Marcelo Alessandro Rigotti
MLMarisa Rolan Dias Loureiro
Marisa Rolan Dias Loureiro
Os objetivos deste estudo foram caracterizar a produção científica nacional da utilização tópica de ácidos graxos no tratamento de feridas e descrever os efeitos da sua ação nesse processo. Trata-se de uma revisão integrativa da literatura indexada nas bases de dados LILACS e BEDEnf. A coleta de dados ocorreu no mês de dezembro de 2010, com descritores de assuntos controlados e sem delimitação de período de busca. A amostra constitui-se de 09 artigos, sendo, a maioria conduzida em modelos animais e utilizando diferentes composições de ácidos graxos. Diante da escassez de estudos clínicos randomizados controlados em humanos e as limitações desta revisão, não se pôde generalizar, na prática clínica, que os ácidos graxos essenciais influenciam o processo de cicatrização positivamente ou possuem ação antimicrobiana. Assim, há necessidade de realização de pesquisas com maior rigor metodológico comparando as diferentes fórmulas disponíveis contendo ácidos graxos e sua influência no processo cicatricial.

30 June 2017 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
MAMáira Gazzola Arroyo
Máira Gazzola Arroyo
AFAdriano Ferreira
Adriano Ferreira
OFOleci Frota
Oleci Frota
MRMarcelo Alessandro Rigotti
Marcelo Alessandro Rigotti
Denise AndradeDenise Andrade
Denise Andrade
MAMargarete Teresa Gottardo de Almeida
Margarete Teresa Gottardo de Almeida
Laboratory analysis of organisms in water include arduous methods, such as the multiple tube and membrane filter. The ATP bioluminescence system, proposes a new way of measuring cellular material in water by measuring adenosine triphosphate (ATP) levels, which are expressed in relative light units (RLU). The ATP bioluminescence assay has been increasingly used to assess the microbiological safety of the hospital environment. However, there are few studies investigating the use of this methodology to evaluate the microbiological quality of water. The objective of the present study was to verify whether ATP, as measured by the 3 M™ Clean-Trace Water™ ATP test, can be used as an alternative tool for presumptive testing for the presence of microorganisms in hospital water. Water samples (N = 88) were collected from faucets (74) and water purifiers (14) in a university hospital. The sample were filtered by the membrane filter technique (100 mL for bacterial analysis and 100 mL for fungal analysis) and then submitted to ATP bioluminescence assay to the determine quantity of RLU in each sample. In order to compare RLU and the presence of microorganisms, a receiver operating characteristic (ROC) curve was used to calculate sensitivity and specificity (levels higher than 90% were considered significant). In addition, control tests were conducted to compare RLU to the quantities of bacterial and fungal organisms added to distilled water (ANOVA and Tukey’s tests; p ≤ 0.05). This inoculum was compared to RLU emission, and the data were analyzed by calculating the Pearson’s correlation coefficient, with a 95% confidence interval. In the present study, 94.3% of the water samples presented bacterial growth. Of these, 15.6% showed heterotrophic bacteria above recommended levels and fungal contamination was detected in 55.6% of samples. Sensitivity and specificity of the samples were not significant (< 90%), and the correlation between ATP and the presence of these microorganisms in the samples (hospital water) was not significant, whereas, in distilled water, the results revealed a significant difference (p < 0.0001). These results demonstrated that the ATP test cannot be used as an alternative tool for presumptive assessment of the presence of microorganisms in water.

1 December 2017 in Revista Brasileira de Enfermagem
Verified
Journal Article
Open access
PDF file
OFOleci Frota
Oleci Frota
AFAdriano Ferreira
Adriano Ferreira
OGOdanir Garcia Guerra
Odanir Garcia Guerra
MRMarcelo Alessandro Rigotti
Marcelo Alessandro Rigotti
Denise AndradeDenise Andrade
Denise Andrade
MAMargarete Teresa Gottardo de Almeida
Margarete Teresa Gottardo de Almeida
Objective: to assess the correlation among the ATP-bioluminescence assay, visual inspection and microbiological culture in monitoring the efficiency of cleaning and disinfection (C&D) of high-touch clinical surfaces (HTCS) in a walk-in emergency care unit. Method: a prospective and comparative study was carried out from March to June 2015, in which five HTCS were sampled before and after C&D by means of the three methods. The HTCS were considered dirty when dust, waste, humidity and stains were detected in visual inspection; when ≥2.5 colony forming units per cm2 were found in culture; when ≥5 relative light units per cm2 were found at the ATP-bioluminescence assay. Results: 720 analyses were performed, 240 per method. The overall rates of clean surfaces per visual inspection, culture and ATP-bioluminescence assay were 8.3%, 20.8% and 44.2% before C&D, and 92.5%, 50% and 84.2% after C&D, respectively (p<0.001). There were only occasional statistically significant relationships between methods. Conclusion: the methods did not present a good correlation, neither quantitative nor qualitatively.

29 April 2019 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
MFMara Cristina Furlan
Mara Cristina Furlan
AFAdriano Ferreira
Adriano Ferreira
LBLarissa da Silva Barcelos
Larissa da Silva Barcelos
MRMarcelo Alessandro Rigotti
Marcelo Alessandro Rigotti
Alvaro Francisco Lopes de SousaAlvaro Francisco Lopes de Sousa
Alvaro Francisco Lopes de Sousa
Mayckel Da Silva BarretoMayckel Da Silva Barreto
Mayckel Da Silva Barreto
Cleaning and disinfection processes must be improved so that there is a reduction in environmental contamination of frequent-contact surfaces. The objective of this study was to evaluate cleaning and disinfection of surfaces at a specialized healthcare unit after an intervention program. Exploratory, longitudinal, and correlational study carried out in a medium-complexity clinic. Two hundred and forty samples from five surfaces were collected during three phases: diagnosis; implementation of an intervention program; and evaluation of immediate and long-term effects. In total, 720 evaluations were made, performed through three monitoring methods: visual inspection; adenosine triphosphate bioluminescence assay (ATP); and aerobic colony count (ACC). The Wilcoxon, Mann-Whitney, and Fisher’s Exact tests were run to analyze data statistically. Cleaning and disinfection of surfaces were not being performed properly in most cases. Failure rates of surfaces reached 37.5 and 100% when the ATP and ACC procedures were used, respectively. However, after an intervention program, an improvement occurred. Success rates increased by 43.96% (ATP) and 12.46% (ACC) in phase I, by 70.6% (ATP) and 82.3% (ACC) immediately after interventions, and by 76.52% (ATP) and 85.76% (ACC) two months after the changes, showing that the program was effective. The present study reveals that implementing intervention actions with a cleaning and healthcare team brings benefits to prevent the spread of pathogenic agents through frequently touched hospital surfaces.

1 January 2020 in Revista Brasileira de Enfermagem
Verified
Journal Article
Open access
PDF file
OFOleci Frota
Oleci Frota
AFAdriano Ferreira
Adriano Ferreira
MRMarcelo Alessandro Rigotti
Marcelo Alessandro Rigotti
Denise AndradeDenise Andrade
Denise Andrade
NBNájla Moreira Amaral Borges
Nájla Moreira Amaral Borges
Marcos Antonio Ferreira JúniorMarcos Antonio Ferreira Júnior
Marcos Antonio Ferreira Júnior
Objective: To discuss the methods employed to evaluate the effectiveness of clinical surface cleaning and disinfection (C&D). Method: This is a theoretical reflection based on scientific studies and the experience of the authors. Knowledge and current gaps, the need for further studies, and practical application of the methods were approached. Results: There are four main methods used to evaluate the effectiveness of clinical surface C&D: visual inspection, fluorescent markers, microbiological cultures, and adenosine triphosphate (ATP) bioluminescence. The first two are used to evaluate the process and to predict adherence to protocols by the staff, and the last two are employed to evaluate the results, therefore being the most relevant to assess the risk of infection. Final considerations: The ideal method was not found, because all of them showed limitations. There is a need for strategies to optimize the precision of these methods.