Oleci Frota

Dr. Oleci Frota


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2017 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
MAMáira Gazzola Arroyo
Máira Gazzola Arroyo
AFAdriano Ferreira
Adriano Ferreira
OFOleci Frota
Oleci Frota
MRMarcelo Alessandro Rigotti
Marcelo Alessandro Rigotti
Denise AndradeDenise Andrade
Denise Andrade
MAMargarete Teresa Gottardo de Almeida
Margarete Teresa Gottardo de Almeida
Laboratory analysis of organisms in water include arduous methods, such as the multiple tube and membrane filter. The ATP bioluminescence system, proposes a new way of measuring cellular material in water by measuring adenosine triphosphate (ATP) levels, which are expressed in relative light units (RLU). The ATP bioluminescence assay has been increasingly used to assess the microbiological safety of the hospital environment. However, there are few studies investigating the use of this methodology to evaluate the microbiological quality of water. The objective of the present study was to verify whether ATP, as measured by the 3 M™ Clean-Trace Water™ ATP test, can be used as an alternative tool for presumptive testing for the presence of microorganisms in hospital water. Water samples (N = 88) were collected from faucets (74) and water purifiers (14) in a university hospital. The sample were filtered by the membrane filter technique (100 mL for bacterial analysis and 100 mL for fungal analysis) and then submitted to ATP bioluminescence assay to the determine quantity of RLU in each sample. In order to compare RLU and the presence of microorganisms, a receiver operating characteristic (ROC) curve was used to calculate sensitivity and specificity (levels higher than 90% were considered significant). In addition, control tests were conducted to compare RLU to the quantities of bacterial and fungal organisms added to distilled water (ANOVA and Tukey’s tests; p ≤ 0.05). This inoculum was compared to RLU emission, and the data were analyzed by calculating the Pearson’s correlation coefficient, with a 95% confidence interval. In the present study, 94.3% of the water samples presented bacterial growth. Of these, 15.6% showed heterotrophic bacteria above recommended levels and fungal contamination was detected in 55.6% of samples. Sensitivity and specificity of the samples were not significant (< 90%), and the correlation between ATP and the presence of these microorganisms in the samples (hospital water) was not significant, whereas, in distilled water, the results revealed a significant difference (p < 0.0001). These results demonstrated that the ATP test cannot be used as an alternative tool for presumptive assessment of the presence of microorganisms in water.

29 March 2023 in Australian Critical Care
Verified
Journal Article
Closed access
OFOleci Frota
Oleci Frota
JPJéssica N. Pinho
Jéssica N. Pinho
MFMarcos A. Ferreira-Júnior
Marcos A. Ferreira-Júnior
ESElaine C.F.B. Sarti
Elaine C.F.B. Sarti
FPFabiana M. Paula
Fabiana M. Paula
DFDanielle N. Ferreira
Danielle N. Ferreira

1 January 2018 in Texto & Contexto - Enfermagem
Verified
Journal Article
Open access
PDF file
PMPaula Knoch Mendonça
Paula Knoch Mendonça
MLMarisa Dias Rolan Loureiro
Marisa Dias Rolan Loureiro
OFOleci Frota
Oleci Frota
ASAlbert Schiaveto de Souza
Albert Schiaveto de Souza
RESUMO Objetivo: descrever as ações de enfermagem prescritas por enfermeiros para a prevenção de lesões por pressão e sua ocorrência em centros de terapia intensiva. Método: estudo transversal, descritivo e analítico, de abordagem quantitativa conduzido em duas instituições hospitalares de ensino de Campo Grande, Brasil. A coleta ocorreu entre março e junho de 2016 com 104 participantes. Os dados foram submetidos à análise estatística. Resultados: foi encontrada associação estatística entre as ações de mudança de decúbito, aplicação de cobertura hidrocoloide em região sacral, realização de higiene externa, troca de fixação do cateter orotraqueal e/ou cateter nasoenteral e inspeção da pele com a ausência de lesões por pressão. A ocorrência de lesões por pressão foi encontrada em 49% dos clientes em ambas as instituições. Conclusão: a elaboração e implementação de protocolos, o acompanhamento dos registros e dos grupos de maior risco são estratégias que direcionam a prescrição de ações preventivas adequadas para lesões por pressão.

26 March 2018 in The Open Nursing Journal
Verified
Journal Article
Open access
PDF file
ASAires G. Santos-Junior
Aires G. Santos-Junior
AFAdriano Ferreira
Adriano Ferreira
OFOleci Frota
Oleci Frota
MRMarcelo A. Rigotti
Marcelo A. Rigotti
LBLarissa da S. Barcelos
Larissa da S. Barcelos
MFMara C. R. Furlan
Mara C. R. Furlan
Background: Failures in the processes of cleaning and disinfecting health service surfaces may result in the spread and transfer of pathogens that are often associated with healthcare-related infections and outbreaks. Aims: To assess the effectiveness of environmental surface cleaning and disinfection in a hospital clinic. Method: The study was conducted in a nursing ward with 45 beds. A total of 80 samples from five high-touch surfaces were evaluated before and after cleaning and disinfection, using the following methods: visual inspection, adenosine triphosphate bioluminescence assay, aerobic colony count, Staphylococcus aureus colony count, and evaluation of resistance to methicillin. The data analysis used nonparametric comparative and correlative tests to observe any differences in the pre- and post- cleaning and disinfection results for the surfaces assessed. Results: Effective cleaning and disinfection had a significant effect on only two surfaces when measured for the presence of adenosine triphosphate, the inner bathroom door handle (p=0.007) and the toilet bowl (p=0.01). When evaluated for Staphylococcus aureus colony count, the toilet flush handle also demonstrated a significant effect (p=0.04). Conclusion: The effectiveness of cleaning and disinfection of the surfaces tested was not satisfactory. An educational intervention is recommended for the cleaning and disinfection staff and the nursing team at the healthcare facility. Relevance to Clinical Practice: The data in the study revealed that daily hospital cleaning and disinfection in the sampled sites are not sufficient in medical and surgical wards. Hospital cleanliness must be reevaluated from the point of view of materials, such as an adequate supply of clean cloths, in addition to establishing more precise cleanliness protocols and accurate monitoring systems.

1 January 2019 in Escola Anna Nery
Verified
Journal Article
Open access
PDF file
LGLayala de Souza Goulart
Layala de Souza Goulart
Marcos Antonio Ferreira JúniorMarcos Antonio Ferreira Júnior
Marcos Antonio Ferreira Júnior
ESElaine Cristina Fernandes Baez Sarti
Elaine Cristina Fernandes Baez Sarti
Alvaro Francisco Lopes de SousaAlvaro Francisco Lopes de Sousa
Alvaro Francisco Lopes de Sousa
AFAdriano Ferreira
Adriano Ferreira
OFOleci Frota
Oleci Frota
Objective: To evaluate nurses' knowledge about the definitions of Sepsis-3 and updates to the Surviving Sepsis Campaign. Methods: This descriptive study was carried out from July to August 2018, with 30 nurses from four wards of a large university hospital. For data collection, we created, structured, and validated a questionnaire composed of socio-demographic/occupational data and knowledge test. Results: Only 16.6% of the professionals received in-service training on the subject. There was no implementation of sepsis protocols in the institution, although 96.6% of the participants considered their implementation necessary. Professionals aged ≥35 years old had a higher level of knowledge about the new definition of sepsis (p=0.042). The knowledge about volume resuscitation (p=0.001) and use of vasopressors (p=0.025) was greater in those with ≥10.5 years of experience in the profession. Nurses from the clinical units presented a higher level of knowledge about the organic dysfunctions caused by sepsis (p=0.025). Conclusion and implications for the practice: Nurses do not have satisfactory knowledge for the proper identification, treatment, and clinical management of sepsis. There is a need for greater professional, institutional, and political incentives to implement a permanent education and the sepsis protocol.

1 December 2017 in Revista Brasileira de Enfermagem
Verified
Journal Article
Open access
PDF file
OFOleci Frota
Oleci Frota
AFAdriano Ferreira
Adriano Ferreira
OGOdanir Garcia Guerra
Odanir Garcia Guerra
MRMarcelo Alessandro Rigotti
Marcelo Alessandro Rigotti
Denise AndradeDenise Andrade
Denise Andrade
MAMargarete Teresa Gottardo de Almeida
Margarete Teresa Gottardo de Almeida
Objective: to assess the correlation among the ATP-bioluminescence assay, visual inspection and microbiological culture in monitoring the efficiency of cleaning and disinfection (C&D) of high-touch clinical surfaces (HTCS) in a walk-in emergency care unit. Method: a prospective and comparative study was carried out from March to June 2015, in which five HTCS were sampled before and after C&D by means of the three methods. The HTCS were considered dirty when dust, waste, humidity and stains were detected in visual inspection; when ≥2.5 colony forming units per cm2 were found in culture; when ≥5 relative light units per cm2 were found at the ATP-bioluminescence assay. Results: 720 analyses were performed, 240 per method. The overall rates of clean surfaces per visual inspection, culture and ATP-bioluminescence assay were 8.3%, 20.8% and 44.2% before C&D, and 92.5%, 50% and 84.2% after C&D, respectively (p<0.001). There were only occasional statistically significant relationships between methods. Conclusion: the methods did not present a good correlation, neither quantitative nor qualitatively.