Influences of the vortex finder diameter and length on the performance of a 50 mm diameter hydrocyclone for particle separation were investigated comprehensively, and the grade efficiencies of particles as well as the cut-size were analyzed detailedly. The results indicated that the separation efficiency could be promoted by employing a vortex finder with a small diameter and appropriate length, and the optimum length highly depends on the vortex finder diameter. It is observed that the optimum length of the vortex finder increases first and then decreases with the increase of its diameter. Additionally, the grade efficiencies demonstrate that large particles (>25 μm) can be almost entirely separated when the vortex finder diameter is lower than 20 mm, and large particles will escape from the vortex finder if the vortex finder diameter is too large (i.e., 25 mm). Besides, the impacts of the vortex finder diameter and its length on the cut-size are negligible when a small diameter vortex finder (less than 20 mm) is employed, while the cut-size increases significantly when a large vortex finder is used. Finally, empirical correlations have been established to quantitatively predict the optimum vortex finder length, separation efficiency, and Euler number.
Bubble growth and formation process directly determines the bubble size, which is crucial for gas-liquid flow systems. Understanding the behaviors of bubble growth and formation in detail is crucial for predicting bubble diameter. This study investigated the effects of orifice parameters ( e.g. , orifice size, contact angle), fluid properties ( e.g. , liquid viscosity, density, surface tension coefficient), and operating conditions ( e.g. , gas inlet velocity, gravitational acceleration) on bubble growth and detachment characteristics ( e.g. , bubble shape, detached diameter, time) under quasi-static conditions using Coupled Level-Set/Volume-of-Fluid method. Empirical correlations of bubble detachment diameter, shape, bubble rising velocity, and bubble-induced liquid velocity at relatively low gas flow rates were proposed to understand the bubble growth mechanism. The mechanism of bubble formation under different orifice wettability conditions was revealed by establishing the relationship between critical and static contact angles. Finally, a new bubble diameter model was developed by considering the effects of a broad range of fluid properties, orifice size, contact angle, and inlet gas velocity. The new model significantly extends the applicability of the traditional bubble formation theoretical model derived from the simple buoyancy force and surface tension force balance, individually decreasing the deviations of predicted bubble diameter at the contact angles of 52 and 105° from 47.3 and 10.47 %–5.41 and 8.14 % and providing some theoretical basis for bubble formation and the reasonable closure of interphase force models based on bubble morphology.
2 July 2023 in The Canadian Journal of Chemical Engineering
To achieve efficient bubble refinement under high gas–liquid ratio (GLR) conditions in industrial applications, this study investigates the effects of Venturi geometry parameters and operating conditions on bubble size distribution under high GLR conditions. Experiments were conducted with throat velocities ranging from 4.34 to 13.02 m/s and GLRs from 10% to 60%, examining the effects of throat diameters (4 mm and 8 mm) and divergent angles (7.5°, 10°, and 12.5°). A novel baffled Venturi bubble generator was designed by maintaining constant throat flow area and principal parameters. Results showed that Venturi tubes with an 8 mm throat diameter produced smaller bubble sizes at higher liquid flow rates. In contrast, excessively large divergent angles produced unfavorable larger bubble sizes due to higher GLR and flow separation. Based on experimental data (Reynolds number range: 12,163–106,084), a comprehensive bubble size prediction model was established, which simultaneously considers the effects of throat diameter and divergent angle. Increasing the liquid flow rate and reducing the GLR effectively minimize bubble size, while the newly developed bubble generator demonstrates superior performance compared to conventional Venturi designs. These findings provide practical references for the design and industrial application of Venturi bubble generators under high GLR conditions.
A Laval nozzle is a pivotal component of supersonic separation technology for dehydration, but its performance is constrained by low separation efficiency due to intractable conflicts between droplet nucleation and growth rates. To address this issue, this work for the first time applied the Foelsch-MOC method to design an expansion section with a first-order differentiable and second-order continuous profile. A numerical model for pure water vapor condensation based on the ideal gas equation of state (EOS) was then established to optimize nozzle structures for droplet growth. Major findings revealed that the droplet radius of the Foelsch-MOC nozzle was 30.5% higher than that of the conical nozzle, while its outlet liquid mass fraction was 5.8% lower. The liquefaction capacity was found to increase first and then decrease with the expansion coefficient, peaking at 0.5. Moreover, increasing the axis shift from 9.3 mm to 25 mm promoted the outlet liquid mass fraction by 1.2% and decreased the droplet radius by 9.3%, thereby improving liquefaction capacity. These results highlight the droplet growth superiority of the novel expansion profile, providing a valuable guideline for designing nozzles that simultaneously ensure liquefaction efficiency and facilitate droplet development.