Paolo Papa

Dr. Paolo Papa

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2017 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
ABAndrea Bearzotti
Andrea Bearzotti
Antonella MacagnanoAntonella Macagnano
Antonella Macagnano
PPPaolo Papa
Paolo Papa
Iole VendittiIole Venditti
Iole Venditti
EZEmiliano Zampetti
Emiliano Zampetti

12 March 2021 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
Ilaria FratoddiIlaria Fratoddi
Ilaria Fratoddi
Sara CerraSara Cerra
Sara Cerra
TSTommaso A. Salamone
Tommaso A. Salamone
RFRaoul Fioravanti
Raoul Fioravanti
FSFabio Sciubba
Fabio Sciubba
ABAndrea Bearzotti
Andrea Bearzotti

29 June 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Antonella MacagnanoAntonella Macagnano
Antonella Macagnano
FMFabricio Nicolas Molinari
Fabricio Nicolas Molinari
PPPaolo Papa
Paolo Papa
TMTiziana Mancini
Tiziana Mancini
Stefano LupiStefano Lupi
Stefano Lupi
Fabrizio De CesareFabrizio De Cesare
Fabrizio De Cesare
Detecting volatile organic compounds (VOCs) emitted from different plant species and their organs can provide valuable information about plant health and environmental factors that affect them. For example, limonene emission can be a biomarker to monitor plant health and detect stress. Traditional methods for VOC detection encounter challenges, prompting the proposal of novel approaches. In this study, we proposed integrating electrospinning, molecular imprinting, and conductive nanofibers to fabricate limonene sensors. In detail, polyvinylpyrrolidone (PVP) and polyacrylic acid (PAA) served here as fiber and cavity formers, respectively, with multiwalled carbon nanotubes (MWCNT) enhancing conductivity. We developed one-step monolithic molecularly imprinted fibers, where S(−)-limonene was the target molecule, using an electrospinning technique. The functional cavities were fixed using the UV curing method, followed by a target molecule washing. This procedure enabled the creation of recognition sites for limonene within the nanofiber matrix, enhancing sensor performance and streamlining manufacturing. Humidity was crucial for sensor working, with optimal conditions at about 50% RH. The sensors rapidly responded to S(−)-limonene, reaching a plateau within 200 s. Enhancing fiber density improved sensor performance, resulting in a lower limit of detection (LOD) of 137 ppb. However, excessive fiber density decreased accessibility to active sites, thus reducing sensitivity. Remarkably, the thinnest mat on the fibrous sensors created provided the highest selectivity to limonene (Selectivity Index: 72%) compared with other VOCs, such as EtOH (used as a solvent in nanofiber development), aromatic compounds (toluene), and two other monoterpenes (α-pinene and linalool) with similar structures. These findings underscored the potential of the proposed integrated approach for selective VOC detection in applications such as precision agriculture and environmental monitoring.

7 October 2018 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Antonella MacagnanoAntonella Macagnano
Antonella Macagnano
PPPaolo Papa
Paolo Papa
JAJoshua Avossa
Joshua Avossa
VPViviana Perri
Viviana Perri
Marcello MarelliMarcello Marelli
Marcello Marelli
NPNicola Pirrone
Nicola Pirrone
Passive sampling systems (PASs) are a low cost strategy to quantify Hg levels in air over both different environmental locations and time periods of few hours to weeks/months. For this reason, novel nanostructured materials have been designed and developed. They consist of an adsorbent layer made of titania nanoparticles (TiO2NPs, ≤25 nm diameter) finely decorated with gold nanoparticles. The TiO2NPs functionalization occurred for the photocatalytic properties of titania-anatase when UV-irradiated in an aqueous solution containing HAuCl4. The resulting nanostructured suspension was deposited by drop-casting on a thin quartz slices, dried and then incorporated into a common axial sampler to be investigated as a potential PAS device. The morphological characteristics of the sample were studied by High-Resolution Transmission Electron Microscopy, Atomic Force Microscopy, and Optical Microscopy. UV-Vis spectra showed a blue shift of the membrane when exposed to Hg0 vapors. The adsorbed mercury was thermally desorbed for a few minutes, and then quantified by a mercury vapor analyzer. Such a sampling system reported an efficiency of adsorption that was equal to ≈95%. Temperature and relative humidity only mildly affected the membrane performances. These structures seem to be promising candidates for mercury samplers, due to both the strong affinity of gold with Hg, and the wide adsorbing surface.

4 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
PPPaolo Papa
Paolo Papa
Giuseppina LucianiGiuseppina Luciani
Giuseppina Luciani
RGRossella Grappa
Rossella Grappa
Virginia VeneziaVirginia Venezia
Virginia Venezia
Ettore GuerrieroEttore Guerriero
Ettore Guerriero
Antonella MacagnanoAntonella Macagnano
Antonella Macagnano
A nanostructured sensing platform was developed by integrating gold-decorated lignin nanoparticles (AuLNPs) into electrospun polylactic acid (PLA) fibre mats. The composite material combines the high surface-to-volume ratio of PLA nanofibres with the chemical functionality of lignin—a polyphenolic biopolymer rich in hydroxyl and aromatic groups—enabling selective interactions with volatile amines through hydrogen bonding and Van der Waals forces. The embedded gold nanoparticles (AuNPs) further enhance the sensor’s electrical conductivity and provide catalytic sites for improved analyte interaction. The sensor exhibited selective adsorption of amine vapours, showing particularly strong affinity for dimethylamine (DMA), with a limit of detection (LOD) of approximately 440 ppb. Relative humidity (RH) was found to significantly influence sensor performance by facilitating amine protonation, thus promoting interaction with the sensing surface. The developed sensor demonstrated excellent selectivity, sensitivity and reproducibility, highlighting its potential for real-time detection of amines in environmental monitoring, industrial safety and healthcare diagnostics.

18 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
EZEmiliano Zampetti
Emiliano Zampetti
MMMaria Aurora Mancuso
Maria Aurora Mancuso
FDFabrizio Dirri
Fabrizio Dirri
EPErnesto Palomba
Ernesto Palomba
PPPaolo Papa
Paolo Papa
Diego ScaccabarozziDiego Scaccabarozzi
Diego Scaccabarozzi
Suspended particulate matter (PMx) is one of the most important environmental pollutants. Miniaturized sensors capable of measuring and analyzing PMx are crucial in environmental research fields. The quartz crystal microbalance (QCM) is one of the most well-known sensors that could be used to monitor PMx. In general, in environmental pollution science, PMx is divided into two main categories correlated to particle diameter (e.g., PM < 2.5 µm and PM < 10 µm). QCM-based systems are capable of measuring this range of particles, but there is an important issue that limits the application. In fact, if particles with different diameters are collected on QCM electrodes, the response will be a result of the total mass of particles; there are no simple methods to discriminate the mass of the two categories without the use of a filter or manipulation during sampling. The QCM response depends on particle dimensions, fundamental resonant frequency, the amplitude of oscillation, and system dissipation properties. In this paper, we study the effects of oscillation amplitude variations and fundamental frequency (10, 5, and 2.5 MHz) values on the response, when particle matter with different sizes (2 µm and 10 µm) is deposited on the electrodes. The results showed that the 10 MHz QCM was not capable of detecting the 10 µm particles, and its response was not influenced by oscillation amplitude. On the other hand, the 2.5 MHz QCM detected the diameters of both particles, but only if a low amplitude value was used.