Wide-bandgap power devices, particularly silicon carbide (SiC) MOSFETs, have seen widespread adoption in electric vehicle (EV) motor drive systems due to their superior switching characteristics, including high switching speeds and high switching frequencies. However, these advantages exacerbate motor terminal overvoltage, with peaks reaching twice the inverter output voltage, causing insulation breakdown in windings and bearing electro-corrosion, which shorten motor lifespan. Traditional overvoltage prediction methods, such as distributed parameter models or detailed ladder network approaches, require extensive system parameters and involve high computational loads, while simplified models lack generality. To address these issues, this paper proposes a simplified prediction method based on a lumped ladder network model combined with frequency scanning. The approach uses impedance analysis to identify anti-resonance frequencies, enabling direct estimation of overvoltage amplitudes without prior knowledge of cable or motor specifics. Experimental validation on a SiC-based drive system demonstrates prediction errors below 10% and a reduction in computational time compared to conventional methods.
The three-phase line-voltage cascaded Boost high power factor rectifier topology has been extensively studied for front-end rectification in high-power charging equipment. However, obvious current distortion occurs near the input voltage zero-crossing point under high-power conditions, which introduces severe harmonics and degrades system stability. Conventional studies often attribute zero-crossing distortion to spike distortion and discontinuous inductor conduction, yet these explanations cannot fully account for the waveform distortion observed in practical engineering scenarios. Based on the one-cycle controlled three-phase Boost PFC converter, this paper establishes a dynamic model to analyze the evolution of distortion under power-frequency grid and various load conditions. The study reveals the key source of current zero-crossing distortion: the fundamental phase shift of input current induced by inductor inertia and digital control delay. Furthermore, a reference current phase-lead scheme is adopted to suppress current zero-crossing distortion. Simulation and experimental results demonstrate that the proposed model can accurately capture current distortion characteristics. This phase compensation strategy can effectively improve the input current waveform, reduce harmonic content and enhance system stability near the rated operating condition, providing theoretical basis and technical support for the optimal design of PFC systems in high-power DC charging piles.