Hyunju Lee

Dr. Hyunju Lee

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2016 in Nanomaterials
Verified
Journal Article
Open access
PDF file
KYKwang Sik Yu
Kwang Sik Yu
MLMeng Meng Lin
Meng Meng Lin
HLHyunju Lee
Hyunju Lee
Ki-Sik TaeKi-Sik Tae
Ki-Sik Tae
BKBo Sun Kang
Bo Sun Kang
DKDo Kyung Kim
Do Kyung Kim
The present report proposes a more rational hyaluronic acid (HA) conjugation protocol that can be used to modify the surface of the superparamagnetic iron oxide nanoparticles (SPIONs) by covalently binding the targeting molecules (HA) with glutamic acid as a molecular linker on peripheral surface of SPIONs. The synthesis of HA-Glutamic Acid (GA)@SPIONs was included oxidization of nanoparticle’s surface with H2O2 followed by activation of hydroxyl group and reacting glutamic acid as an intermediate molecule demonstrating transfection of lung cancer cells. Fourier transform infrared (FTIR) and zeta-potential studies confirmed the chemical bonding between amino acid linker and polysaccharides. 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) cytotoxicity assay showed that HA-SPIONs-treated cells remained 82.9% ± 2.7% alive at high particle dosage (200 µg/mL iron concentration), whereas GA-SPIONs and bare SPIONs (B-SPIONs) treated cells had only 59.3% ± 13.4% and 26.5% ± 3.1% survival rate at the same conditions, respectively. Confocal microscopy analysis showed increased cellular internalization of HA-SPIONs compared to non-interacting agarose coated SPIONs (AgA-SPIONs).

3 October 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
HSHyun Seok Song
Hyun Seok Song
HGHui-Gyeong Gong
Hui-Gyeong Gong
HLHyunju Lee
Hyunju Lee
HKHyungsuk Kim
Hyungsuk Kim
Ki-Sik TaeKi-Sik Tae
Ki-Sik Tae
Adding a fibular strut bone graft to locking plate fixation has been introduced to improve stability and prevent varus collapse. The purpose of this study was to perform finite element analysis (FEA) of the biomechanical characteristics of different insertion angles of the fibular strut graft in proximal humerus fractures. Proximal humerus fractures with metaphyseal comminution and instability were simulated by creating wedge-shaped osteotomies medially and laterally for varus and valgus models, respectively. Three-dimensional finite element models were reconstructed from computed tomography images. A locking compression plate with a length of 90 mm (three holes) was applied to the proximal humerus fracture model. Fibular allografts were inserted at 0° and 30° to the humeral shaft. Axial and traction forces of 70°, 90°, and 110° relative to the vertical axis were applied to each model to simulate stress on the plate and graft. At axial loads, stresses in both the plate and the graft were lower when the graft was inserted at 0° than at 30°. Under traction loads, plate stress was lower with 30° insertion. Graft stress was also lower with 30° in most experimental conditions in both the valgus and varus models. These findings suggest that oblique insertion may provide biomechanical advantages under traction forces in unstable proximal humerus fractures.

1 June 2024 in Journal of the Korean Society for Precision Engineering
Verified
Journal Article
Closed access
SLSeohyun Lee
Seohyun Lee
YJYoonsung Jang
Yoonsung Jang
HLHyunju Lee
Hyunju Lee
KTKisik Tae
Kisik Tae
Brain-computer interface (BCI) is a technology used in various fields to analyze electroencephalography (EEG) signals to recognize an individual

19 January 2026 in International Journal of Precision Engineering and Manufacturing
Verified
Journal Article
Open access
PDF file
SBSo-Jeong Bae
So-Jeong Bae
HGHui-Gyeong Gong
Hui-Gyeong Gong
HLHyunju Lee
Hyunju Lee
Ki-Sik TaeKi-Sik Tae
Ki-Sik Tae
Myofascial pain syndrome (MPS) of the upper trapezius is characterized by trigger-point–related pain, restricted cervical motion, and altered muscle activation patterns. Electrical stimulation is a widely used noninvasive intervention, yet the influence of different frequency–intensity combinations remains insufficiently defined. This randomized controlled trial compared the short-term effects of low-frequency high-intensity (LFHI) and high-frequency low-intensity (HFLI) transcutaneous electrical nerve stimulation (TENS) on pain, cervical range of motion (ROM), muscle tone, and muscle activation in adults with upper trapezius MPS. Thirty participants were randomly assigned to either the LFHI or HFLI protocol and received 20-minute treatments twice daily for five days. Pain intensity (numeric rating scale), pressure pain threshold, cervical ROM, upper trapezius muscle tone, and surface electromyography (sEMG) of the upper trapezius, middle deltoid, and levator scapulae were assessed before and after intervention. Both LFHI and HFLI stimulation significantly reduced pain intensity and increased pressure pain threshold ( p < .01). Cervical ROM in all directions improved significantly in both groups ( p < .01), accompanied by reductions in upper trapezius muscle tone ( p < .01). sEMG analysis revealed decreased upper trapezius and levator scapulae activity and increased deltoid activation in both groups ( p < .01). Although no significant intergroup differences were observed for most parameters, the deltoid-to–upper trapezius activation ratio increased significantly only in the HFLI group ( p < .05), indicating a more favorable motor recruitment pattern. These findings demonstrate that both LFHI and HFLI electrical stimulation protocols effectively relieve pain, reduce muscle hypertonicity, and enhance cervical mobility in individuals with MPS. While clinical outcomes were comparable, HFLI stimulation may provide additional benefits in normalizing shoulder muscle activation. Electrical stimulation represents a practical and accessible modality for restoring short-term neuromuscular function in MPS.

8 June 2026 in Healthcare
Verified
Journal Article
Open access
PDF file
HJHyewon Jeon
Hyewon Jeon
SPSunbeom Park
Sunbeom Park
SBSungwoo Bang
Sungwoo Bang
Ki-Sik TaeKi-Sik Tae
Ki-Sik Tae
HLHyunju Lee
Hyunju Lee
Background: Portable biofeedback technologies are increasingly used in rehabilitation; however, the validity of surface electromyography (sEMG) as a surrogate indicator of deep abdominal muscle function remains unclear. This study aimed to validate a portable sEMG-based visual biofeedback system by examining its relationship with ultrasound-derived measures of deep abdominal muscle activation. Methods: Twenty-nine healthy adults were randomly assigned to a Visual Biofeedback group (n = 14) or a Verbal Feedback group (n = 15). Both groups performed a standardized 2-week core stabilization program. Muscle activation of the deep abdominal muscle complex (transversus abdominis–internal oblique; TrA–IO) and external oblique (EO) was measured using sEMG (%MVIC), while ultrasound imaging was used to assess transversus abdominis thickness and contractile activity (ADIM–Rest index). Between-group differences and correlations between EMG and ultrasound variables were analyzed. Results: The Visual Biofeedback group demonstrated significantly greater improvements in TrA–IO activation and in the preferential activation ratio (TrA–IO/EO) compared to the Verbal group (p = 0.004). Ultrasound analysis revealed significantly greater increases in TrA thickness and contractile activity in the Visual group (p < 0.001). A significant positive correlation was observed between changes in TrA–IO activation and TrA thickness (ρ = 0.51, p < 0.001). Conclusions: Portable sEMG-based visual biofeedback demonstrated physiological relevance by reflecting ultrasound-derived changes in deep abdominal muscle function. These findings support the use of sEMG as a practical surrogate tool for monitoring deep core muscle activation and highlight the potential of portable biofeedback systems in scalable and accessible rehabilitation.