The present report proposes a more rational hyaluronic acid (HA) conjugation protocol that can be used to modify the surface of the superparamagnetic iron oxide nanoparticles (SPIONs) by covalently binding the targeting molecules (HA) with glutamic acid as a molecular linker on peripheral surface of SPIONs. The synthesis of HA-Glutamic Acid (GA)@SPIONs was included oxidization of nanoparticle’s surface with H2O2 followed by activation of hydroxyl group and reacting glutamic acid as an intermediate molecule demonstrating transfection of lung cancer cells. Fourier transform infrared (FTIR) and zeta-potential studies confirmed the chemical bonding between amino acid linker and polysaccharides. 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) cytotoxicity assay showed that HA-SPIONs-treated cells remained 82.9% ± 2.7% alive at high particle dosage (200 µg/mL iron concentration), whereas GA-SPIONs and bare SPIONs (B-SPIONs) treated cells had only 59.3% ± 13.4% and 26.5% ± 3.1% survival rate at the same conditions, respectively. Confocal microscopy analysis showed increased cellular internalization of HA-SPIONs compared to non-interacting agarose coated SPIONs (AgA-SPIONs).
10 June 2022 in International Journal of Precision Engineering and Manufacturing
Adding a fibular strut bone graft to locking plate fixation has been introduced to improve stability and prevent varus collapse. The purpose of this study was to perform finite element analysis (FEA) of the biomechanical characteristics of different insertion angles of the fibular strut graft in proximal humerus fractures. Proximal humerus fractures with metaphyseal comminution and instability were simulated by creating wedge-shaped osteotomies medially and laterally for varus and valgus models, respectively. Three-dimensional finite element models were reconstructed from computed tomography images. A locking compression plate with a length of 90 mm (three holes) was applied to the proximal humerus fracture model. Fibular allografts were inserted at 0° and 30° to the humeral shaft. Axial and traction forces of 70°, 90°, and 110° relative to the vertical axis were applied to each model to simulate stress on the plate and graft. At axial loads, stresses in both the plate and the graft were lower when the graft was inserted at 0° than at 30°. Under traction loads, plate stress was lower with 30° insertion. Graft stress was also lower with 30° in most experimental conditions in both the valgus and varus models. These findings suggest that oblique insertion may provide biomechanical advantages under traction forces in unstable proximal humerus fractures.
19 January 2026 in International Journal of Precision Engineering and Manufacturing
Myofascial pain syndrome (MPS) of the upper trapezius is characterized by trigger-point–related pain, restricted cervical motion, and altered muscle activation patterns. Electrical stimulation is a widely used noninvasive intervention, yet the influence of different frequency–intensity combinations remains insufficiently defined. This randomized controlled trial compared the short-term effects of low-frequency high-intensity (LFHI) and high-frequency low-intensity (HFLI) transcutaneous electrical nerve stimulation (TENS) on pain, cervical range of motion (ROM), muscle tone, and muscle activation in adults with upper trapezius MPS. Thirty participants were randomly assigned to either the LFHI or HFLI protocol and received 20-minute treatments twice daily for five days. Pain intensity (numeric rating scale), pressure pain threshold, cervical ROM, upper trapezius muscle tone, and surface electromyography (sEMG) of the upper trapezius, middle deltoid, and levator scapulae were assessed before and after intervention. Both LFHI and HFLI stimulation significantly reduced pain intensity and increased pressure pain threshold ( p < .01). Cervical ROM in all directions improved significantly in both groups ( p < .01), accompanied by reductions in upper trapezius muscle tone ( p < .01). sEMG analysis revealed decreased upper trapezius and levator scapulae activity and increased deltoid activation in both groups ( p < .01). Although no significant intergroup differences were observed for most parameters, the deltoid-to–upper trapezius activation ratio increased significantly only in the HFLI group ( p < .05), indicating a more favorable motor recruitment pattern. These findings demonstrate that both LFHI and HFLI electrical stimulation protocols effectively relieve pain, reduce muscle hypertonicity, and enhance cervical mobility in individuals with MPS. While clinical outcomes were comparable, HFLI stimulation may provide additional benefits in normalizing shoulder muscle activation. Electrical stimulation represents a practical and accessible modality for restoring short-term neuromuscular function in MPS.
Background: Portable biofeedback technologies are increasingly used in rehabilitation; however, the validity of surface electromyography (sEMG) as a surrogate indicator of deep abdominal muscle function remains unclear. This study aimed to validate a portable sEMG-based visual biofeedback system by examining its relationship with ultrasound-derived measures of deep abdominal muscle activation. Methods: Twenty-nine healthy adults were randomly assigned to a Visual Biofeedback group (n = 14) or a Verbal Feedback group (n = 15). Both groups performed a standardized 2-week core stabilization program. Muscle activation of the deep abdominal muscle complex (transversus abdominis–internal oblique; TrA–IO) and external oblique (EO) was measured using sEMG (%MVIC), while ultrasound imaging was used to assess transversus abdominis thickness and contractile activity (ADIM–Rest index). Between-group differences and correlations between EMG and ultrasound variables were analyzed. Results: The Visual Biofeedback group demonstrated significantly greater improvements in TrA–IO activation and in the preferential activation ratio (TrA–IO/EO) compared to the Verbal group (p = 0.004). Ultrasound analysis revealed significantly greater increases in TrA thickness and contractile activity in the Visual group (p < 0.001). A significant positive correlation was observed between changes in TrA–IO activation and TrA thickness (ρ = 0.51, p < 0.001). Conclusions: Portable sEMG-based visual biofeedback demonstrated physiological relevance by reflecting ultrasound-derived changes in deep abdominal muscle function. These findings support the use of sEMG as a practical surrogate tool for monitoring deep core muscle activation and highlight the potential of portable biofeedback systems in scalable and accessible rehabilitation.
Microfluidic systems offer significant advantages in handling small sample volumes while enabling high-throughput experimentation and precise flow control. Surface wettability critically governs droplet-generation efficiency and flow characteristics in microfluidic channels. Topographic modulation of polymer surfaces provides a simple, chemical-free route to tune wettability. We present a surface-engineering strategy that patterns nanoscale wrinkles on polydimethylsiloxane (PDMS), optimized at 40 ϵ prestrain, 100 W oxygen-plasma power, and 12 min exposure. The resulting wrinkled PDMS exhibited stable hydrophobicity sufficient for reliable water-in-oil droplet generation without any coating. Wettability was quantified by contact-angle measurements, and wrinkle morphology was verified by 3D laser profilometry and atomic force microscopy. Orientation-dependent hydrophobicity and droplet-generation behavior were also assessed. Finite-element simulations showed enhanced interfacial slip at wrinkled walls relative to flat walls under matched driving and captured orientation effects on near-wall kinematics. The approach circumvents hydrophobic-recovery and coating-compatibility issues commonly encountered with silane-treated PDMS. Therefore, the results establish mechanically engineered surface wrinkles as an effective, chemical-free means to tune hydrophobicity in microfluidic devices, with direct relevance to droplet-based assays and lab-on-a-chip platforms.
About Me
Reseaaecher in orthpedic biomechanics & rehabilitaion engineering for disability people.
Reseaaecher in orthpedic biomechanics & rehabilitaion engineering for disability people.