Elza  Cloete

Elza Cloete

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in The Journal of Pediatrics
Verified
Journal Article
Closed access
ECElza Cloete
Elza Cloete
FBFrank H. Bloomfield
Frank H. Bloomfield
LSLynn Sadler
Lynn Sadler
MLMonique W.M. de Laat
Monique W.M. de Laat
AFA. Kirsten Finucane
A. Kirsten Finucane
TGThomas L. Gentles
Thomas L. Gentles

1 March 2019 in Archives of Disease in Childhood
Verified
Journal Article
Closed access
PDF file
ECElza Cloete
Elza Cloete
LSLynn Sadler
Lynn Sadler
Frank BloomfieldFrank Bloomfield
Frank Bloomfield
SCSue Crengle
Sue Crengle
TPTeuila Percival
Teuila Percival
TGThomas L Gentles
Thomas L Gentles
Objective To investigate the relationship between ethnicity and health outcomes among fetuses and infants with congenital left heart obstruction (LHO). Design A retrospective population-based review was conducted of fetuses and infants with LHO including all terminations, stillbirths and live births from 20 weeks’ gestation in New Zealand over a 9-year period. Disease incidence and mortality were analysed by ethnicity and by disease type: hypoplastic left heart syndrome (HLHS), aortic arch obstruction (AAO), and aortic valve and supravalvular anomalies (AVSA). Results Critical LHO was diagnosed in 243 fetuses and newborns. There were 125 with HLHS, 112 with AAO and 6 with isolated AVSA. The incidence of LHO was significantly higher among Europeans (0.59 per 1000) compared with Māori (0.31 per 1000; p<0.001) and Pacific peoples (0.27 per 1000; p=0.002). Terminations were uncommon among Māori and Pacific peoples. Total case fatality was, however, lower in Europeans compared with other ethnicities (42% vs 63%; p=0.002) due to a higher surgical intervention rate and better infant survival. The perinatal and infant mortality rate was 82% for HLHS, 15% for AAO and 2% for AVSA. Conclusion HLHS carries a high perinatal and infant mortality risk. There are ethnic differences in the incidence of and mortality from congenital LHO with differences in mortality rate suggesting inequities may exist in the perinatal management pathway.

23 July 2019 in Acta Paediatrica
Verified
Journal Article
Open access
PDF file
ECElza Cloete
Elza Cloete
Frank BloomfieldFrank Bloomfield
Frank Bloomfield
SCSharnie A. Cassells
Sharnie A. Cassells
MLMonique W. M. de Laat
Monique W. M. de Laat
LSLynn Sadler
Lynn Sadler
TGThomas L. Gentles
Thomas L. Gentles
Aim: Assess the potential additional benefit from pulse oximetry screening in the early detection of critical congenital heart disease in a country with a well‐developed antenatal ultrasound screening programme.Methods: Live‐born infants, pregnancy terminations and stillbirths from 20 weeks’ gestational age, between 2013 and 2015, with critical cardiac defects defined as primary or secondary targets of pulse oximetry screening were identified. Critical defects were those resulting in the death of a fetus or an infant in the first 28 days after birth, or a defect requiring intervention in the first 28 days.Results: Two hundred and sixty‐eight infants and Fetuses were identified. Antenatal detection rates improved from 69% to 77% over the study period. An associated co‐morbidity improved antenatal detection rates. Twenty‐seven live‐born infants were diagnosed after discharge: 15 aortic arch obstruction (AAO); 10 d‐loop transposition of the great arteries (d‐TGA), and two total anomalous pulmonary venous drainage (TAPVD). Of these, five with AAO, nine with d‐TGA and likely both with TAPVD could potentially have been detected with oximetry screening.Conclusion: The antenatal detection of critical cardiac anomalies continues to improve in New Zealand. Despite high antenatal detection rates for most lesions, universal postnatal oximetry screening has the potential to improve early detection.

8 August 2019 in Acta Paediatrica
Verified
Journal Article
Open access
ECElza Cloete
Elza Cloete
TGThomas L. Gentles
Thomas L. Gentles
DWDianne R. Webster
Dianne R. Webster
SDSarka Davidkova
Sarka Davidkova
LDLesley A. Dixon
Lesley A. Dixon
FCfor the Pulse Oximetry Screening Steering Committee
for the Pulse Oximetry Screening Steering Committee
Aim To assess local and individual factors that should be considered in the design of a pulse oximetry screening strategy in New Zealand's midwifery-led maternity setting. Methods An intervention study was conducted over 2 years. Three hospitals and four primary maternity units participated in the study. Post-ductal saturation levels were measured on well infants with a gestation of >= 35 weeks. Infant activity and age (hours) at the time of the test were recorded. Results Screening was performed on 16 644 of 27 172 (61%) eligible infants. The age at which the screening algorithm was initiated varied significantly among centres. The probability of achieving a pass result (saturations >= 95%) in the context of no underlying pathology ranged from .94 for an unsettled infant screened <4 hours of age to .99 (P < .001) when the test was performed after 24 hours on a settled infant. Forty-eight (0.3%) infants failed to reach saturation targets: 37 had significant pathology of which three had cardiac disease. Conclusion Screening practices were influenced by the setting in which it was undertaken. Infant activity and age at the time of testing can influence saturation levels. Screening is associated with the identification of significant non-cardiac pathology.

Verified
Journal Article
Open access
PDF file
ECElza Cloete
Elza Cloete
TGThomas L. Gentles
Thomas L. Gentles
RLRobert A. Lutter
Robert A. Lutter
KRKelly Richards
Kelly Richards
KWKim Ward
Kim Ward
Frank BloomfieldFrank Bloomfield
Frank Bloomfield
Pulse oximetry screening to detect hypoxaemia in newborn infants was introduced at birthing facilities in New Zealand during a feasibility study determining barriers and enablers to universal screening in a midwifery-led maternity system focused on community values and partnership with, and participation by, consumers. During the 2-year study period, parents of infants who underwent pulse oximetry screening were invited to complete a written survey to investigate consumer satisfaction. Respondents ranked their satisfaction with the test and with information resources on a five-level Likert scale. Additional comments were added in a free text space. Participation was voluntary and anonymous. A total of 657 surveys were included for analysis. Consumers were satisfied with the screening procedure; 94% either agreed or strongly agreed that it is an important health check. Although the quality of information sources was deemed good, a third of participants indicated a wish to obtain more information. Some participants stated that retention of information was an issue, reporting that they were fatigued following the birth. Consumers are receptive to pulse oximetry screening. Sharing information (while considering the receptivity of parents) and engaging the parents of newborn infants are factors that are paramount to the success of newborn screening initiatives.

18 August 2019 in BMJ Open
Verified
Journal Article
Open access
PDF file
ECElza Cloete
Elza Cloete
TGThomas L Gentles
Thomas L Gentles
LDLesley A Dixon
Lesley A Dixon
DWDianne R Webster
Dianne R Webster
JAJoshua D Agnew
Joshua D Agnew
Frank BloomfieldFrank Bloomfield
Frank Bloomfield
Objectives The aim of this study was to conduct New Zealand-specific research to inform the design of a pulse oximetry screening strategy that ensures equity of access for the New Zealand maternity population. Equity is an important consideration as the test has the potential to benefit some populations and socioeconomic groups more than others. Setting New Zealand has an ethnically diverse population and a midwifery-led maternity service. One quaternary hospital and urban primary birthing unit (Region A), two regional hospitals (Region B) and three regional primary birthing units (Region C) from three Health Boards in New Zealand’s North Island participated in a feasibility study of pulse oximetry screening. Home births in these regions were also included. Participants There were 27 172 infants that satisfied the inclusion criteria; 16 644 (61%) were screened. The following data were collected for all well newborn infants with a gestation age ≥35 weeks: date of birth, ethnicity, type of maternity care provider, deprivation index and screening status (yes/no). The study was conducted over a 2-year period from May 2016 to April 2018. Results Screening rates improved over time. Infants born in Region B (adjusted OR=0.75; 95% CI 0.67 to 0.83) and C (adjusted OR=0.29; 95% CI 0.27 to 0.32) were less likely to receive screening compared with those born in Region A. There were significant associations between screening rates and deprivation, ethnicity and maternity care provider. Lack of human and material resources prohibited universal access to screening. Conclusion A pulse oximetry screening programme that is sector-led is likely to perpetuate inequity. Screening programmes need to be designed so that resources are distributed in the way most likely to optimise health outcomes for infants born with cardiac anomalies. Ethics approval This study was approved by the Health and Disability Ethics Committees of New Zealand (15/NTA/168).