Sylvia H Heywang-Köbrunner

Prof. Dr. Sylvia H Heywang-Köbrunner

National Reference Center Mammography Munich, Munich, Bavaria, Germany
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2020 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
W(With Language Review By Europa Donna–The European Breast Cancer Coalition For The European Society Of Breast Imaging (Eusobi)
With Language Review By Europa Donna–The European Breast Cancer Coalition For The European Society Of Breast Imaging (Eusobi)
UBUlrich Bick
Ulrich Bick
RTRubina M. Trimboli
Rubina M. Trimboli
AAAlexandra Athanasiou
Alexandra Athanasiou
CBCorinne Balleyguier
Corinne Balleyguier
FSFrancesco Sardanelli
Francesco Sardanelli
We summarise here the information to be provided to women and referring physicians about percutaneous breast biopsy and lesion localisation under imaging guidance. After explaining why a preoperative diagnosis with a percutaneous biopsy is preferred to surgical biopsy, we illustrate the criteria used by radiologists for choosing the most appropriate combination of device type for sampling and imaging technique for guidance. Then, we describe the commonly used devices, from fine-needle sampling to tissue biopsy with larger needles, namely core needle biopsy and vacuum-assisted biopsy, and how mammography, digital breast tomosynthesis, ultrasound, or magnetic resonance imaging work for targeting the lesion for sampling or localisation. The differences among the techniques available for localisation (carbon marking, metallic wire, radiotracer injection, radioactive seed, and magnetic seed localisation) are illustrated. Type and rate of possible complications are described and the issue of concomitant antiplatelet or anticoagulant therapy is also addressed. The importance of pathological-radiological correlation is highlighted: when evaluating the results of any needle sampling, the radiologist must check the concordance between the cytology/pathology report of the sample and the radiological appearance of the biopsied lesion. We recommend that special attention is paid to a proper and tactful approach when communicating to the woman the need for tissue sampling as well as the possibility of cancer diagnosis, repeat tissue sampling, and or even surgery when tissue sampling shows a lesion with uncertain malignant potential (also referred to as “high-risk” or B3 lesions). Finally, seven frequently asked questions are answered.

1 August 2006 in Journal of the American College of Surgeons
Verified
Journal Article
Closed access
GSGordon F. Schwartz
Gordon F. Schwartz
UVUmberto Veronesi
Umberto Veronesi
KCKrishna B. Clough
Krishna B. Clough
JDJ. Michael Dixon
J. Michael Dixon
IFIan S. Fentiman
Ian S. Fentiman
LSLawrence J. Solin
Lawrence J. Solin

25 October 2021 in European Radiology
Verified
Journal Article
Open access
PDF file
SHSylvia H Heywang-Köbrunner
Sylvia H Heywang-Köbrunner
AJAlexander Jänsch
Alexander Jänsch
AHAstrid Hacker
Astrid Hacker
SWSina Weinand
Sina Weinand
TVTobias Vogelmann
Tobias Vogelmann
Objectives: Digital breast tomosynthesis (DBT) plus digital mammography (DM) in screening is problematic due to increased radiation by the double exposure. Synthesised two-dimensional mammography (s2D) calculated from DBT datasets at no additional dose appears a sensible alternative compared to adding DM. This systematic review and meta-analysis focuses on screening performance outcomes in women screened with DBT plus s2D compared to DM alone. Methods: PubMed was searched from January 1, 2010, to September 2, 2020. Studies comparing DBT plus s2D to DM alone in breast cancer screening were included. Pooled risk ratios (RR) were estimated for cancer detection rates (CDR), recall rates, interval cancer rates (ICR), biopsy rates, and positive predictive values for recalls (PPV-1), for biopsies recommended (PPV-2), and for biopsies performed (PPV-3). Sensitivity analyses were performed using the leave-one-out approach. Risk of bias (RoB) was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool. Results: Twelve papers covering 414,281 women were included from 766 records identified. CDR is increased ([RR, 95% CI] 1.35, 1.20–1.52), recall rates are decreased (0.79, 0.64–0.98), and PPV-1 is increased (1.69, 1.45–1.96) when using DBT plus s2D compared to DM alone. ICR and biopsy rates did not differ, but PPV-2 respectively PPV-3 increased with DBT plus s2D (1.57, 1.08–2.28 respectively 1.36, 1.17–1.58). Overall RoB of studies was assessed to be low. Conclusion: Results show improved diagnostic outcomes with DBT plus s2D compared to DM alone and underline the value of DBT in combination with s2D in breast cancer screening. Key Points: • DBT plus s2D is associated with higher CDR, lower recall rates, and a higher PPV-1 compared to DM alone in breast cancer screening. • No differences in biopsy rates were found between screening modalities, but PPV-2 and PPV-3 were higher in women screened with DBT plus s2D compared to DM alone. • We identified inconsistent results of ICR in two studies comparing DBT plus s2D to DM alone—resulting in no differences when pooling ICR in meta-analysis.

1 August 2013 in The Breast
Verified
Journal Article
Open access
SHSylvia H Heywang-Köbrunner
Sylvia H Heywang-Köbrunner
AHAstrid Hacker
Astrid Hacker
SSStefan Sedlacek
Stefan Sedlacek
To provide an overview of the principle of current breast MRI, the available evidence concerning its indications and optimum use and future potentials. To date sensitivities of 90-91% have been achieved with a specificity of 72-75%. MRI is the most sensitive method for detecting invasive carcinoma and comparable to mammography concerning detection of DCIS. The achievable specificity, false positive and biopsy rates, however, are much lower than for screening mammography thus do not allow its use for screening of the general population. Indications with proven advantages concern screening of women at high risk and special diagnostic problems that cannot be solved by conventional imaging and percutaneous biopsy: search for primary tumour in CUP syndrome, differentiation of nipple retraction, differentiation of scarring versus recurrence and selected difficult cases. There is no proven benefit for its general use for preoperative staging. One major problem may concern the imperfect interface between imaging and surgery. Further research is also needed for the use of MRI in women at intermediate risk. In women at low risk MRI screening is not recommended. Novel possibilities of MRI concern diffusion weighted imaging as well as MR spectroscopy. Their value for improved lesion differentiation is not yet fully established. Their main potential appears to concern an improved and earlier prediction of response to neoadjuvant therapy. Future developments might address development of more specific contrast agents, replacement of vascular enhancing agents by special MR techniques, testing of sodium MRI or image fusion with other imaging modalities. MRI allows new patho-physiological information and thus can complement the information available by conventional methods. Present research should concentrate on improving specificity, improving the interface of imaging and surgery and has to include outcome analyses. Due to issues of specificity the responsible use of MRI should be limited to appropriate indications.

28 May 2015 in European Radiology
Verified
Journal Article
Open access
PDF file
SHSylvia H Heywang-Köbrunner
Sylvia H Heywang-Köbrunner
ISI. Schreer
I. Schreer
AHA. Hacker
A. Hacker
MNM. R. Noftz
M. R. Noftz
AKAlexander Katalinic
Alexander Katalinic
Twenty-five-year follow-up data of the Canadian National Breast Cancer Screening Study (CNBSS) indicated no mortality reduction. What conclusions should be drawn? After conducting a systematic literature search and narrative analysis, we wish to recapitulate important details of this study, which may have been neglected: Sixty-eight percent of all included cancers were palpable, a situation that does not allow testing the value of early detection. Randomisation was performed at the sites after palpation, while blinding was not guaranteed. In the first round, this “randomisation" assigned 19/24 late stage cancers to the mammography group and only five to the control group, supporting the suspicion of severe errors in the randomisation process. The responsible physicist rated mammography quality as “far below state of the art of that time". Radiological advisors resigned during the study due to unacceptable image quality, training, and medical quality assurance. Each described problem may strongly influence the results between study and control groups. Twenty-five years of follow-up cannot heal these fundamental problems. This study is inappropriate for evidence-based conclusions. The technology and quality assurance of the diagnostic chain is shown to be contrary to today's screening programmes, and the results of the CNBSS are not applicable to them. Key Points • The evidence base of the Canadian study (CNBSS) has to be questioned. • Severe flaws in the randomization process and test methods occurred. • Problems were criticized during and after conclusion of the trial by experts. • The results are not applicable to quality-assured screening programs. • The evidence base of this study must be re-analyzed.

1 October 2013 in Geburtshilfe und Frauenheilkunde
Verified
Journal Article
Open access
PDF file
SHSylvia H Heywang-Köbrunner
Sylvia H Heywang-Köbrunner
KBK. Bock
K. Bock
WHW. Heindel
W. Heindel
GHG. Hecht
G. Hecht
LRL. Regitz-Jedermann
L. Regitz-Jedermann
VKV. Kaeaeb-Sanyal
V. Kaeaeb-Sanyal
Introduction: Since 2008 the German Mammography Screening Programme has been available throughout Germany to all women aged between 50 and 69. The programme strictly follows the European Guidelines. There are controversial discussions in the media as well as in the specialised press. Materials and Methods: Overview of the available data with regard to an evaluation of randomised studies and with regard to quality-assured screening programmes in accordance with EU Guidelines (including data from 18 screening countries). Results: Positive effects of screening: reduction in mortality, less invasive treatment. Negative effects: False-positive diagnoses and biopsy recommendations, so-called overdiagnoses, radiation dose. Limits of screening: Interval carcinomas, incomplete reduction in mortality. A mathematical synopsis of the latest publications from the European screening programmes with the diagnosis rates in Germany determined from > 4.6 million screening examinations produces the following: a total of 10 000 mammograms are created for 1000 women (P) taking part in the Mammography Screening Programme (each of whom undergoes 10 mammograms in 20 years). Overall, the risk of triggering breast cancer through a mammogram is very clearly below the annual natural risk of suffering from breast cancer. In the German screening, of these 1000 women, an average of 288 women are called back once in 20 years as a result of changes that are ultimately benign (< 3 % per cycle). Of these, 74 of the 288 women undergo a biopsy due to a benign change (false-positive biopsy recommendations, usually punch or vacuum biopsies). According to EUROSCREEN, 71 carcinomas develop among participants (56 are discovered in the screening, 15 in the interval), and 67 carcinomas among non-participants (N-P) (in some cases, several years later) during this period. The 4 additional diagnoses among the Ps are referred to as overdiagnoses, as they do not contribute to a reduction in mortality (these participants die beforehand from other causes of death). With regard to the carcinomas that concern the screening periods, 11 women out of 1000 die among the Ps; there are 19 deaths among the N-Ps (within the observation period plus follow-up period). Discussion: The false-positive rate is unavoidable, but is far lower with mammography screening than with other methods. Overdiagnoses are to be expected with any early detection. All calculations require assumptions and are therefore highly discrepant. They have very low evidence levels. The radiation dose should not be an argument against screening when applied correctly due to the very low risk and significant benefits. Interval carcinomas indicate the limits of a mammography screening programme. False-negatives only represent a subset of the interval carcinomas and are not to be equated with them. There is a very high evidence level for a significant reduction in mortality through mammography screening. For the first time, an independent expert commission has confirmed the results of the randomised studies and the statement of the WHO from 2002 and their further validity. Participants can expect a reduction in mortality of 30 %. Data from the current European screening programmes confirm a mortality reduction of 43 %, corresponding to 8/19 saved lives among 71 women with breast cancer or 1000 asymptomatic Ps. Many additional Ps benefit from less invasive treatment due to the early detection. Conclusions: As a result of the risk/benefit ratio, mammography screening should absolutely be recommended to asymptomatic women aged between 50–69. High importance is given to the provision of education for women by the treating gynaecologists as regards the opportunities for quality-assured early detection available to them in the healthcare system. Einleitung: Seit 2008 steht das Deutsche Mammografie-Screening-Programm flächendeckend allen Frauen zwischen 50 und 69 Jahren zur Verfügung. Das Programm folgt streng den europäischen Leitlinien. In den Medien wie auch in der Fachpresse gibt es kontroverse Diskussionen. Material und Methoden: Überblick über die Datenlage bez. der Bewertung der randomisierten Studien und bez. der qualitätsgesicherten Screening-Programme gemäß EU-Leitlinien (inklusive Daten aus 18 Screening-Ländern). Ergebnisse: Positive Wirkungen des Screenings: Mortalitätsreduktion, schonendere Behandlung. Negative Wirkungen: Falsch positive Befundungen und Biopsieempfehlungen, sog. Überdiagnosen, Strahlendosis. Grenzen des Screenings: Intervallkarzinome, nicht vollständige Mortalitätsreduktion. Eine rechnerische Synopse der aktuellsten Veröffentlichungen der europäischen Screening-Programme mit den Abklärungsraten in Deutschland ermittelt aus > 4,6 Mio. Screening-Untersuchungen ergibt folgendes: Von 1000 Frauen (TN), die am Mammografie-Screening-Programm teilnehmen (jede davon erhält in 20 Jahren 10 Mammografien), werden insgesamt 10 000 Mammografien erstellt. Insgesamt liegt das Risiko, durch eine Mammografie Brustkrebs auszulösen, ganz deutlich unter dem jährlichen natürlichen Risiko, an Brustkrebs zu erkranken. Im deutschen Screening werden von diesen 1000 Frauen wegen schlussendlich benigner Veränderungen durchschnittlich 288 Frauen 1-mal in 20 Jahren wiedereinbestellt (< 3 % pro Runde). Davon erhalten 74 der 288 Frauen eine Biopsie wegen einer benignen Veränderung (falsch positive Biopsieempfehlungen, i. d. R. Stanz- oder Vakuumbiopsie). Bezogen auf diesen Zeitraum entstehen entsprechend EUROSCREEN 71 Karzinome bei den Teilnehmerinnen (56 werden im Screening, 15 im Intervall entdeckt), bei Nichtteilnehmerinnen (N-TN) 67 Karzinome (z. T. mehrere Jahre später). Die 4 zusätzlichen Diagnosen bei den TN werden als Überdiagnosen bezeichnet, da sie nicht zur Mortalitätsreduktion beitragen (diese Teilnehmerinnen versterben vorher an...