Chuming Zhao

Chuming Zhao

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
CZChuming Zhao
Chuming Zhao
KKKatherine E. Knisely
Katherine E. Knisely
DCDeborah J. Colesa
Deborah J. Colesa
BPBryan E. Pfingst
Bryan E. Pfingst
YRYehoash Raphael
Yehoash Raphael
KGKarl Grosh
Karl Grosh
The ability to measure the voltage readout from a sensor implanted inside the living cochlea enables continuous monitoring of intracochlear acoustic pressure locally, which could improve cochlear implants. We developed a piezoelectric intracochlear acoustic transducer (PIAT) designed to sense the acoustic pressure while fully implanted inside a living guinea pig cochlea. The PIAT, fabricated using micro-electro-mechanical systems (MEMS) techniques, consisted of an array of four piezoelectric cantilevers with varying lengths to enhance sensitivity across a wide frequency bandwidth. Prior to implantation, benchtop tests were conducted to characterize the device performance in air and in water. When implanted in the cochlea of an anesthetized guinea pig, the in vivo voltage response from the PIAT was measured in response to 80–95 dB sound pressure level 1–14 kHz sinusoidal acoustic excitation at the entrance of the guinea pig’s ear canal. All sensed signals were above the noise floor and unaffected by crosstalk from the cochlear microphonic or external electrical interference. These results demonstrate that external acoustic stimulus can be sensed via the piezoelectric voltage response of the implanted MEMS transducer inside the living cochlea, providing key steps towards developing intracochlear acoustic sensors to replace external or subcutaneous microphones for auditory prosthetics.

3 June 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
AHAlison E. Hake
Alison E. Hake
CZChuming Zhao
Chuming Zhao
WSWang-Kyung Sung
Wang-Kyung Sung
KGKarl Grosh
Karl Grosh
The ubiquity of vibration sensors and accelerometers, as well as advances in microfabrication technologies, have led to the development of implantable devices for biomedical applications. This work describes a piezoelectric microelectromechanical systems accelerometer designed for potential use in auditory prostheses. The design includes an aluminum nitride bimorph beam with a silicon proof mass. Analytic models of the device sensitivity and noise are presented. These lead to a minimum detectable acceleration cost function for the sensor that can be used to optimize sensor designs more effectively than typical sensitivity maximizing or electrical noise minimizing approaches. A fabricated device with a $1~\mu \text{m}$ thick, $100~\mu \text{m}$ long, and $700~\mu \text{m}$ wide beam and a $400~\mu \text{m}$ thick, $63~\mu \text{m}$ long, and $740~\mu \text{m}$ wide proof mass is tested experimentally. Results indicate accurate modeling of the system sensitivity up to the first resonant frequency (1420 Hz). The low-frequency sensitivity of the device is 1.3 mV/g, and the input referred noise is 36.3 nV/ $\sqrt {\mathrm{Hz}}$ at 100 Hz and 11.8 nV/ $\sqrt {\mathrm{Hz}}$ at 1 kHz. The resulting minimum detectable acceleration at 100 Hz and 1 kHz is $28~\mu \text{g}/\sqrt {\mathrm{Hz}}$ and $9.1~\mu \text{g}/\sqrt {\mathrm{Hz}}$ , respectively. A brief explanation of the use of the validated cost function for sensor design is provided, as well as an example comparing the piezoelectric sensor design to another from the literature. It is concluded that a traditional single-resonance design cannot compete with the performance of acoustic sensors; therefore, novel device designs must be considered for implantable auditory prosthesis applications.

1 May 2023 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
PDF file
TXTong Xiao
Tong Xiao
BXBuye Xu
Buye Xu
CZChuming Zhao
Chuming Zhao
Active noise control (ANC) systems are commonly designed to achieve maximal sound reduction regardless of the incident direction of the sound. When desired sound is present, the state-of-the-art methods add a separate system to reconstruct it. This can result in distortion and latency. In this work, we propose a multi-channel ANC system that only reduces sound from undesired directions, and the system truly preserves the desired sound instead of reproducing it. The proposed algorithm imposes a spatial constraint on the hybrid ANC cost function to achieve spatial selectivity. Based on a six-channel microphone array on a pair of augmented eyeglasses, results show that the system minimized only noise coming from undesired directions. The control performance could be maintained even when the array was heavily perturbed. The proposed algorithm was also compared with the existing methods in the literature. Not only did the proposed system provide better noise reduction, but it also required much less effort. The binaural localization cues did not need to be reconstructed since the system preserved the physical sound wave from the desired source.

1 June 2018 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
CZChuming Zhao
Chuming Zhao
KKKatherine E. Knisely
Katherine E. Knisely
KGKarl Grosh
Karl Grosh

5 October 2020 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
AHAlison E. Hake
Alison E. Hake
CZChuming Zhao
Chuming Zhao
LPLichuan Ping
Lichuan Ping
KGKarl Grosh
Karl Grosh
Piezoelectric acoustic transducers consisting of a circular aluminum nitride and silicon nitride unimorph diaphragm and an encapsulated air-filled back cavity are reported. Analytical and finite element analysis models are used to design the transducer to achieve low minimum detectable pressure (MDP) within chosen size restrictions. A series of transducers with varying radii are fabricated using microelectromechanical systems (MEMS) techniques. Experimental results are reported for a transducer with a 175 μm radius on a 400 × 500 × 500 μm3 die exhibiting structural resonances at 552 kHz in air and 133 kHz in water. The low-frequency (10 Hz–50 kHz) sensitivity is 1.87 μV/Pa (−114.5 dB re 1 V/Pa) in both air and water. The sensor has an MDP of 43.7 mPa/ Hz (67 dB SPL) at 100 Hz and 10.9 mPa/ Hz (55 dB SPL) at 1 kHz. This work contributes a set of design rules for MEMS piezoelectric diaphragm transducers that focuses on decreasing the MDP of the sensor through size, material properties, and residual stress considerations.

1 January 2015 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
KKKatherine Knisely
Katherine Knisely
CZChuming Zhao
Chuming Zhao
KGKarl Grosh
Karl Grosh
A completely implantable artificial organ of Corti (CIAO) was fabricated using batch MEMS processing techniques. A silicon backbone supports five piezoelectric cantilevers, each of which is designed to have an in vivo resonance corresponding to its tonotopic location in the guinea pig ST (20-40 kHz). An attachable polymer ribbon cable extends 4cm from the probe to an electrode bay, where electrical connections to each cantilever are accessed. The actuation responses of the fabricated devices were measured using laser vibrometry confirming the fluid-loaded resonance conforming to the straight section of the first turn of the guinea pig cochlea. First generation devices have been fabricated and the actuated resonances were measured to range from 80.3-134.2kHz in air and 24.3-41.0 kHz in water.