3 June 2021 in IEEE Sensors Journal
The ubiquity of vibration sensors and accelerometers, as well as advances in microfabrication technologies, have led to the development of implantable devices for biomedical applications. This work describes a piezoelectric microelectromechanical systems accelerometer designed for potential use in auditory prostheses. The design includes an aluminum nitride bimorph beam with a silicon proof mass. Analytic models of the device sensitivity and noise are presented. These lead to a minimum detectable acceleration cost function for the sensor that can be used to optimize sensor designs more effectively than typical sensitivity maximizing or electrical noise minimizing approaches. A fabricated device with a $1~\mu \text{m}$ thick, $100~\mu \text{m}$ long, and $700~\mu \text{m}$ wide beam and a $400~\mu \text{m}$ thick, $63~\mu \text{m}$ long, and $740~\mu \text{m}$ wide proof mass is tested experimentally. Results indicate accurate modeling of the system sensitivity up to the first resonant frequency (1420 Hz). The low-frequency sensitivity of the device is 1.3 mV/g, and the input referred noise is 36.3 nV/ $\sqrt {\mathrm{Hz}}$ at 100 Hz and 11.8 nV/ $\sqrt {\mathrm{Hz}}$ at 1 kHz. The resulting minimum detectable acceleration at 100 Hz and 1 kHz is $28~\mu \text{g}/\sqrt {\mathrm{Hz}}$ and $9.1~\mu \text{g}/\sqrt {\mathrm{Hz}}$ , respectively. A brief explanation of the use of the validated cost function for sensor design is provided, as well as an example comparing the piezoelectric sensor design to another from the literature. It is concluded that a traditional single-resonance design cannot compete with the performance of acoustic sensors; therefore, novel device designs must be considered for implantable auditory prosthesis applications.
5 October 2020 in Applied Physics Letters
Piezoelectric acoustic transducers consisting of a circular aluminum nitride and silicon nitride unimorph diaphragm and an encapsulated air-filled back cavity are reported. Analytical and finite element analysis models are used to design the transducer to achieve low minimum detectable pressure (MDP) within chosen size restrictions. A series of transducers with varying radii are fabricated using microelectromechanical systems (MEMS) techniques. Experimental results are reported for a transducer with a 175 μm radius on a 400 × 500 × 500 μm3 die exhibiting structural resonances at 552 kHz in air and 133 kHz in water. The low-frequency (10 Hz–50 kHz) sensitivity is 1.87 μV/Pa (−114.5 dB re 1 V/Pa) in both air and water. The sensor has an MDP of 43.7 mPa/ (67 dB SPL) at 100 Hz and 10.9 mPa/ (55 dB SPL) at 1 kHz. This work contributes a set of design rules for MEMS piezoelectric diaphragm transducers that focuses on decreasing the MDP of the sensor through size, material properties, and residual stress considerations.
18 May 2023 in IEEE Sensors Journal
For the last 20 years, researchers have developed accelerometers to function as ossicular vibration sensors in order to eliminate the external components of hearing aid and cochlear implant (CI) systems. To date, no accelerometer has met all of the stringent performance requirements necessary to function in this capacity. In this work, we present an accelerometer design with an equivalent noise floor of less than 20 phon equal-loudness-level over a 0.1–8-kHz bandwidth in a package small enough to be implanted in the middle ear. Our approach uses a dual-bandwidth (two sensing elements) microelectromechanical systems (MEMS) piezoelectric accelerometer, sized using an area-minimization process based on an experimentally validated analytical model of the sensor. The resulting bandwidth of the low-frequency sensing element (LFSE) is 0.1–1.25 kHz and that of the high-frequency sensing element (HFSE) is 1.25–8 kHz. These sensing elements fit within a silicon frame that is $795\times 778\,\,\mu \text{m}$ , which can reasonably be housed along with a required integrated circuit (IC) in a $2.2\times 2.7\times1$ -mm package. The estimated total mass of the packaged system is approximately 14 mg. This dual-bandwidth MEMS sensor fills a technological gap in current completely implantable auditory prosthesis (CIAP) research and development by enabling a device capable of meeting physical and performance specifications needed for use in the middle ear.
1 May 2017 in The Journal of the Acoustical Society of America
Acceleration sensors are prevalent in handheld electronics, navigation systems, and physical activity monitors as well as for vibration measurement. There are many measurement applications, such as sensing human middle ear motion, that require miniature, low-noise sensors to detect low-amplitude vibration. Both capacitive and piezoresistive MEMS accelerometers have been used for vibration sensing of the middle ear. Recent capacitive designs are large (base area of 2.5 mm x 6.2 mm) and have a limited bandwidth of 6.44 kHz. Low-noise piezoresistive devices power requirements are high for hearing instruments, greater than 1 mW. Commercial piezoelectric accelerometers are a viable means for vibration detection; while small, they are still large and lacking proper electronic connections for middle ear sensing applications. The aforementioned problems motivate the design of a small, passive, broadband accelerometer with low input referred noise (IRN). In this work, we design a micromachined, piezoelectric bimorph cantilever accelerometer for broadband, low-amplitude vibration sensing. An analytic model is developed to minimize the IRN. The analytic expression allows for rapid design of many system parameters that are verified through finite element analysis.
1 March 2018 in The Journal of the Acoustical Society of America
Sensing human middle ear motion requires miniature, low-noise sensors to detect low-amplitude vibration of the ossicle bones to replace the external microphone in a cochlear implant system. Specifically, a 35 μg/√Hz sensor resolution is needed measure motion at 500 Hz (Young et al., 2012). Motivated by sensing middle ear motion without irreversible alteration to the ossicular chain, a small, piezoelectric accelerometer is considered. Our detailed low-frequency analytical model is used to identify promising micromachined, piezoelectric bimorph cantilever accelerometer designs. We fabricated a first generation of accelerometers using a conservative microfabrication approach, taken to enhance the yield of devices rather than to minimize the input referred noise (IRN). The mathematical model was validated by voltage actuation testing of these accelerometers. The device sensitivity to acceleration is tested, and the resulting IRN is desired to assess the viability of the sensor for the middle ear motion application. The first generation experimental results are compared to the mathematical model to determine the accuracy of the model and the efficacy of the fabrication methodology. This knowledge will influence future sensor designs optimized for minimal IRN.