Dariel Gustavo Hernández-Montalvo

Mr. Dariel Gustavo Hernández-Montalvo

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2022 in Pädi Boletín Científico de Ciencias Básicas e Ingenierías del ICBI
Verified
Journal Article
Open access
PDF file
JSJesús Santiaguillo-Salinas
Jesús Santiaguillo-Salinas
HGHiram Netzahualcóyotl García-Lozano
Hiram Netzahualcóyotl García-Lozano
RGRafael Fernando González-Zárate
Rafael Fernando González-Zárate
DHDariel Gustavo Hernández-Montalvo
Dariel Gustavo Hernández-Montalvo
En este trabajo se presenta el diseño, simulación e implementación de un control para el seguimiento de trayectorias, considerando evasión de colisiones, para un robot móvil AutoMiny versión 4.0. El control de seguimiento está acotado por una función tangente hiperbólico y para la evasión de colisiones se utiliza un campo vectorial repulsivo. Los resultados teóricos obtenidos son validados a través de una simulación numérica y de manera experimental. La implementación se llevó a cabo mediante ROS y un sistema de cámaras OptiTrack.

30 June 2026 in Atmosphere
Verified
Journal Article
Open access
PDF file
DHDariel Gustavo Hernández-Montalvo
Dariel Gustavo Hernández-Montalvo
ARAbelardo Rodríguez-León
Abelardo Rodríguez-León
GOGuillermo Ovando-Chacon
Guillermo Ovando-Chacon
ECEnrique Cruz-Octaviano
Enrique Cruz-Octaviano
MGMario Diaz González
Mario Diaz González
The present study addresses the problems of predicting the distribution of CO2 in a classroom where limited ventilation may compromise air quality. Through Computational Fluid Dynamics (CFD), a detailed analysis of airflow, temperature, and CO2 dispersion was carried out; however, due to its high computational cost, real-time applications are limited. Therefore, this work proposes a simplified CFD approach to model human breathing based on a constant airflow velocity and an average CO2 concentration, preserving mass balance while reducing computational demand. Three mathematical breathing models (constant, complete, and sinusoidal) were formulated and compared through CFD simulation with the classroom model. Subsequently, a CO2 detection module based on SCD40 sensors was developed for the experimental validation of the simplified model, recreating the simulation conditions in a real environment. The results show strong agreement between the simplified model and the complex models, as well as with experimental measurements, with relative errors between 0.05% and 10% at different monitoring points. The proposed model reduced calculation time by more than 98% compared to the sinusoidal model, without compromising accuracy. These results show that the simplified model is an efficient alternative for predicting CO2 concentration, allowing its integration into real-time control systems.