Enrique Cruz-Octaviano

Mr. Enrique Cruz-Octaviano

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2025 in Atmosphere
Verified
Journal Article
Open access
PDF file
ECEnrique Cruz-Octaviano
Enrique Cruz-Octaviano
GOGuillermo Ovando-Chacon
Guillermo Ovando-Chacon
ARAbelardo Rodríguez-León
Abelardo Rodríguez-León
SOSandy Luz Ovando-Chacon
Sandy Luz Ovando-Chacon
Evaluating ventilation behavior inside classrooms in hot climates is fundamental to ensure good indoor air quality and proper thermal comfort, thus guaranteeing a healthy environment for the users. This study analyzes the impact of mixed ventilation strategies, which combine mechanical extractors and organic air cleaners (OACs), on CO2 concentration and temperature distribution in an air-conditioned classroom with closed doors and windows. We used computational fluid dynamics simulations to analyze the effect of different extractor and OACs configurations on airflow distribution and average temperature, as well as the temporal evolution of average CO2 concentrations inside the classroom. The configuration with one extractor and two OACs reduces CO2 concentrations to 613 ppm, representing an effective solution with lower energy consumption. These findings demonstrate that hybrid ventilation systems can significantly improve IAQ and maintain thermal comfort, offering viable and energy-efficient alternatives for enclosed classrooms in hot climate regions.

18 January 2026 in Buildings
Verified
Journal Article
Open access
PDF file
GOGuillermo Ovando-Chacon
Guillermo Ovando-Chacon
ECEnrique Cruz-Octaviano
Enrique Cruz-Octaviano
ARAbelardo Rodríguez-León
Abelardo Rodríguez-León
SOSandy Luz Ovando-Chacon
Sandy Luz Ovando-Chacon
RMRicardo Martinez-Gonzalez
Ricardo Martinez-Gonzalez
Achieving adequate thermal comfort in classrooms in hot cities in southern Mexico is challenging. A heterogeneous distribution of air conditioning flow leads to thermal discomfort, affecting occupants’ academic performance and increasing energy consumption. This study evaluates the thermal comfort of occupants in an air conditioned classroom using computational fluid dynamics. We determined the effects of variations in air conditioning operating parameters (supply angle, velocity, and temperature) on PMV and modified PMV indices. An operating configuration of 60°, 3 m/s, and 22 °C ensures that thermal comfort remains within regulations while optimizing energy consumption, in contrast to the original PMV model. Using the modified PMV model, the values are 0.38 for students and 0.31 for the teacher, with percentages of dissatisfied individuals of 10% and 7.7%, respectively. This study demonstrates the importance of analyzing air conditioning operating parameters to enhance thermal comfort while reducing energy consumption.

30 June 2026 in Atmosphere
Verified
Journal Article
Open access
PDF file
DHDariel Gustavo Hernández-Montalvo
Dariel Gustavo Hernández-Montalvo
ARAbelardo Rodríguez-León
Abelardo Rodríguez-León
GOGuillermo Ovando-Chacon
Guillermo Ovando-Chacon
ECEnrique Cruz-Octaviano
Enrique Cruz-Octaviano
MGMario Diaz González
Mario Diaz González
The present study addresses the problems of predicting the distribution of CO2 in a classroom where limited ventilation may compromise air quality. Through Computational Fluid Dynamics (CFD), a detailed analysis of airflow, temperature, and CO2 dispersion was carried out; however, due to its high computational cost, real-time applications are limited. Therefore, this work proposes a simplified CFD approach to model human breathing based on a constant airflow velocity and an average CO2 concentration, preserving mass balance while reducing computational demand. Three mathematical breathing models (constant, complete, and sinusoidal) were formulated and compared through CFD simulation with the classroom model. Subsequently, a CO2 detection module based on SCD40 sensors was developed for the experimental validation of the simplified model, recreating the simulation conditions in a real environment. The results show strong agreement between the simplified model and the complex models, as well as with experimental measurements, with relative errors between 0.05% and 10% at different monitoring points. The proposed model reduced calculation time by more than 98% compared to the sinusoidal model, without compromising accuracy. These results show that the simplified model is an efficient alternative for predicting CO2 concentration, allowing its integration into real-time control systems.

17 October 2026 in Environments
Verified
Journal Article
Open access
PDF file
ECEnrique Cruz-Octaviano
Enrique Cruz-Octaviano
GOGuillermo Ovando-Chacon
Guillermo Ovando-Chacon
ARAbelardo Rodríguez-León
Abelardo Rodríguez-León
SOSandy Luz Ovando-Chacon
Sandy Luz Ovando-Chacon
In hot climates, classrooms are often air-conditioned to ensure thermal comfort. However, the classrooms remain closed throughout the day to prevent the entry of hot air from outside, which leads to a rapid increase in CO2 levels. In this study, thermal comfort and indoor air quality in a climate-controlled classroom are analyzed by implementing different configurations that consider the use of organic air cleaners, an extractor, variations in the air conditioning supply angle, and two different occupancy levels. The research uses computational fluid dynamics simulations to evaluate CO2 concentration profiles as a function of spatial coordinates and time. Vertical temperature differences for occupants are studied to analyze thermal comfort. Results indicate that configurations with three organic air cleaners, an extractor, and a 60° air-conditioning supply angle produce the largest average reductions in CO2 levels across the entire classroom. Furthermore, the vertical temperature differences for the occupants remain within permissible values. While experimental data support the reference case, the validated CFD model was used to predict the performance of the proposed configurations, establishing a foundation for future field implementation.