Xingxing ZOU Zou

Prof. Xingxing ZOU Zou

College of Civil Engineering, Nanjing Forestry University, Nanjing 210096, China
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2022 in Engineering Structures
Verified
Journal Article
Closed access
FZFeng Zhang
Feng Zhang
CWChenxin Wang
Chenxin Wang
JLJun Liu
Jun Liu
Xingxing ZOU ZouXingxing ZOU Zou
Xingxing ZOU Zou
LSLesley H. Sneed
Lesley H. Sneed
LWLibin Wang
Libin Wang

1 September 2016 in Composite Structures
Verified
Journal Article
Closed access
Xingxing ZOU ZouXingxing ZOU Zou
Xingxing ZOU Zou
Peng FengPeng Feng
Peng Feng
JWJingQuan Wang
JingQuan Wang

1 May 2018 in Composite Structures
Verified
Journal Article
Closed access
Xingxing ZOU ZouXingxing ZOU Zou
Xingxing ZOU Zou
Peng FengPeng Feng
Peng Feng
JWJingquan Wang
Jingquan Wang
YWYuwei Wu
Yuwei Wu
YFYu Feng
Yu Feng

2 October 2023 in Construction and Building Materials
Verified
Journal Article
Closed access
CWChenxin Wang
Chenxin Wang
Xingxing ZOU ZouXingxing ZOU Zou
Xingxing ZOU Zou
LSLesley H Sneed
Lesley H Sneed
FZFeng Zhang
Feng Zhang
Kaiqi ZhengKaiqi Zheng
Kaiqi Zheng
GLGuofen Li
Guofen Li

1 June 2018 in Journal of Composites for Construction
Verified
Journal Article
Closed access
Xingxing ZOU ZouXingxing ZOU Zou
Xingxing ZOU Zou
Peng FengPeng Feng
Peng Feng
JWJingquan Wang
Jingquan Wang
This study investigated the behavior of bolted shear connections for fiber-reinforced polymer (FRP)–concrete hybrid beams. Fourteen push-out tests were conducted with varying parameters of bolt strength, bolt diameter (dbolt ), bolt-embedding length in concrete (hbolt ), FRP shear strength (SFRP ), and the use of ultra-high performance concrete (UHPC). Tests showed that a larger hbolt leads to smaller slip but has only a slight effect on capacity; specimens with a larger dbolt have greater capacity and smaller slip. Specimens with ordinary-strength bolts (OSBs) failed at bolt shank shear, whereas specimens with high-strength bolts (HSB) failed at FRP flange shear-out associated with a significant improvement in capacity compared with those with OSBs. The use of UHPC substantially reduced slip, but did not improve bolt capacity because the two failure modes do not occur in concrete. The prediction equations for capacity associated with these two failure modes were derived by modifying the existing equations. A salient finding in the load-slip curves of HSB specimens was three loading stages with different slopes: compacting, hardening, and softening. This was different from observations in previous studies on head studs in steel-concrete composite beams and FRP bolts/dowels in FRP-concrete hybrid beams. The load-slip curves of specimens with HSB were fitted by a trilinear model to facilitate design and analysis. Finally, design recommendations for bolted connections were formulated after parametric analysis.

3 September 2022 in Engineering Structures
Verified
Journal Article
Closed access
MDMaojun Duan
Maojun Duan
Xingxing ZOU ZouXingxing ZOU Zou
Xingxing ZOU Zou
Yi BaoYi Bao
Yi Bao
GLGuofen Li
Guofen Li
YCYiwei Chen
Yiwei Chen
ZLZhuangzhuang Li
Zhuangzhuang Li