Seismic isolation is an efficient strategy to protect structures from the effects of moderate to severe earthquake shaking. Conventional isolation devices can reduce the structural response in horizontal directions only; however, three-dimensional (3D) ground motions have been observed in earthquake records. In this paper, an innovative 3D seismic isolator is proposed. A new kind of asymmetric oblique hysteretic model is illustrated, and a quasistatic compression test of a model device using three lead rubber bearings (LRBs) is conducted. The test results and theoretical model results match well. A significant asymmetric property is observed in the hysteretic curves. The proposed hysteretic model can efficiently simulate the vertical mechanical behavior of a 3D seismic isolation system. The effects of different parameters are highlighted based on the theoretical mechanical model. The inclination angle, friction coefficient, and second shape factor of the inclined LRBs strongly influence the vertical behavior of the proposed device. A dynamic response analysis of the substructure of a nuclear power plant (NPP) is conducted. The hysteretic curves have the shape of an asymmetric quadrangle; this shape is similar to that observed in the test results. The vertical acceleration response of the vertical isolation structure is reduced by 33% compared with that of a fixed-base structure and reduced by 58% compared with that of a horizontal isolation structure. The proposed 3D isolator can sufficiently isolate the seismic input.
3 January 2022 in Structural Control and Health Monitoring
Laminated rubber bearings have a large compression stiffness and small tension stiffness and isolation layers show rocking deformation under bending moments. The application of isolation technology is limited in high-rise structures due to the unequal compression and tension stiffnesses. The rocking effect of a high-rise isolated structure was investigated in this work. To do this, a dynamic model of a high-rise isolated structure considering non-linear tension behaviour of the isolator and the stiffness centre offset was established. The limit criterion of the rocking angle and the corresponding input peak ground acceleration of the tension limit, damage limit and collapse limit were determined. A shaking table test of the isolated model was conducted and the aspect ratio was found to have a great influence on the structural rocking response. The response of the large aspect ratio (LAR) model was larger than that of a model with a small aspect ratio. The bearings in the LAR model were more likely to be tensioned. The test results and numerical simulations were close, confirming the accuracy of the proposed dynamic model and the limit criteria. Subsequently, dynamic analysis of frame–shear wall structures was conducted and the influence of aspect ratio and earthquake level was investigated. The proposed theories can be applied for direct predictions of rocking response and the performance state of isolators.
15 February 2024 in International Journal of Structural Stability and Dynamics