Owing to special functional requirements of museum, such as great space and story height for exhibitions, large floor slab openings in plan and long span truss in elevation are becoming increasingly considered in museum design, which leads to challenges to structural safety. The aseismic performance of an isolated museum structure in high earthquake intensity regions was thus studied because of its complexity and irregularity. In order to observe the seismic characteristics and verify isolation effect, shaking table tests of a 1/30-scale structural model with and without base isolation bearings have been carried out under minor, moderate, and major earthquakes. The experimental results show that isolated structure dynamic characteristics and isolation effect are stable and storey peak acceleration responses of superstructure are less than that of fixed structure. Storey drifts of isolated structure meet required limits stipulated in Chinese design code and torsion responses of the bearings are not remarkable. It is suggested that seismic performances of complex museum structures have been effectively improved with isolation in use.
1 December 2018 in Journal of Structural Engineering
Seismic isolation is an efficient strategy to protect structures from the effects of moderate to severe earthquake shaking. Conventional isolation devices can reduce the structural response in horizontal directions only; however, three-dimensional (3D) ground motions have been observed in earthquake records. In this paper, an innovative 3D seismic isolator is proposed. A new kind of asymmetric oblique hysteretic model is illustrated, and a quasistatic compression test of a model device using three lead rubber bearings (LRBs) is conducted. The test results and theoretical model results match well. A significant asymmetric property is observed in the hysteretic curves. The proposed hysteretic model can efficiently simulate the vertical mechanical behavior of a 3D seismic isolation system. The effects of different parameters are highlighted based on the theoretical mechanical model. The inclination angle, friction coefficient, and second shape factor of the inclined LRBs strongly influence the vertical behavior of the proposed device. A dynamic response analysis of the substructure of a nuclear power plant (NPP) is conducted. The hysteretic curves have the shape of an asymmetric quadrangle; this shape is similar to that observed in the test results. The vertical acceleration response of the vertical isolation structure is reduced by 33% compared with that of a fixed-base structure and reduced by 58% compared with that of a horizontal isolation structure. The proposed 3D isolator can sufficiently isolate the seismic input.
1 December 2014 in Research in Astronomy and Astrophysics