Ainur Montayeva

Dr. Ainur Montayeva


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2025 in Bulletin of Kazakh Leading Academy of Architecture and Construction
Verified
Journal Article
Closed access
SMS.A. Montayev
S.A. Montayev
AMAinur Montayeva
Ainur Montayeva
AAAliya K. Aldungarova
Aliya K. Aldungarova
NCnternatıonal Educatıonal Corporatıon
nternatıonal Educatıonal Corporatıon
ADAgnieszka Dąbska
Agnieszka Dąbska
The article presents the results of a study on the use of diatomite in ceramic mixtures for the production of high-efficiency wall ceramics. It was established that diatomite samples contain both micro- and mesopores, as well as H3-type hysteresis loops, which confirm their high porosity. The average pore sizes were determined to be 1.5 nm for micropores and 4.4 nm for mesopores. The study identified the main patterns of change in the physical and mechanical properties of ceramic samples depending on the diatomite content at a firing temperature of 1000 °C. Increasing the diatomite content to 50% (by reducing the clay content to 50%) led to a significant decrease in average density and compressive strength. The average density decreased from 1.8 g/cm³ to 1.23 g/cm³, while the compressive strength decreased from 15.2 MPa to 9.6 MPa. At the same time, the total porosity of the samples remained at approximately 53%. A considerable reduction in the thermal conductivity coefficient–from 0.8 to 0.31 W/(m·°C). A comparative analysis of the physical and mechanical properties of the studied ceramic compositions with those of ceramics based on pure clay revealed substantial differences across all property indicators. The samples produced from the modified ceramic composition exhibited a lower average density and more than twice the overall porosity. It was determined that ceramic samples fired at 1000 °C form a sintered microporous structure characterized by low average density, reduced thermal conductivity, and satisfactory compressive strength and water absorption values.

2 March 2025 in Technobius
Verified
Journal Article
Open access
PDF file
AMAinur Montayeva
Ainur Montayeva
Abdulla OmarovAbdulla Omarov
Abdulla Omarov
GTGulshat Tleulenova
Gulshat Tleulenova
Assel SarsembayevaAssel Sarsembayeva
Assel Sarsembayeva
YIYoshinori Iwasaki
Yoshinori Iwasaki
This study examines the behavior of frozen soils at a construction site in Astana, Kazakhstan. Field static load tests (SLT) and dynamic load tests (DLT), were conducted using driven piles embedded in alluvial Quaternary deposits overlying a 2.5 m permafrost layer. SLT results reveal settlements below 20 mm at a maximum load of 1400 kN, supporting a design capacity of 1167 kN after applying a safety factor of 1.2. Notably, creep behavior was observed in the upper soil layers, and lateral displacement patterns indicate complex interactions within the frozen soil. These findings highlight the need for further research into soil creep and lateral deformations in frozen environments.

15 June 2022 in Bulletin of Kazakh Leading Academy of Architecture and Construction
Verified
Journal Article
Closed access
AZA.J. Zhusupbekov
A.J. Zhusupbekov
AMAinur Montayeva
Ainur Montayeva
BSB.T. Shakeshev
B.T. Shakeshev
KNK.A. Narikov
K.A. Narikov
The article presents the results of scientific and experimental work on the study of the effect of quicklime in the composition of a chemical reagent on the depth of thawing in season-ally frozen soils in places where pile foundations are driven. The proposed technology provides for the driving of pile foundations without preliminary drilling of seasonally frozen soil, and the use of low-power units for driving piles.

22 September 2025 in Smart Construction and Sustainable Cities
Verified
Journal Article
Open access
PDF file
Askar ZhussupbekovAskar Zhussupbekov
Askar Zhussupbekov
Abdulla OmarovAbdulla Omarov
Abdulla Omarov
AMAinur Montayeva
Ainur Montayeva
This study compares the bearing capacity results of piles obtained through static and dynamic load tests, using different safety factors. The Static Load Test (SLT) based on GOST standards indicated a bearing capacity of 1400 kN. After applying a safety factor of 1.2, the ultimate capacity was calculated as 1167 kN, considered as the baseline (100%) for comparison. The Cone Penetration Test (CPT) at a depth of 7 m yielded a lower bearing capacity of 930 kN, which, after applying a safety factor of 1.25, resulted in an ultimate capacity of 744 kN (63.8% of the SLT value). The Dynamic Load Test (PDA) according to ASTM standards showed the highest bearing capacity, with an average of 1799 kN. Applying a safety factor of 1.4, the ultimate capacity was determined to be 1285 kN, which is 10% higher than the SLT value (110%). This analysis underscores significant variations in pile bearing capacity depending on the testing method, with dynamic tests generally yielding higher ultimate capacities after adjusting for safety factors.

24 April 2026 in Construction Materials and Products
Verified
Journal Article
Closed access
SMS.A. Montayev
S.A. Montayev
BSB.ZH. Sakhiyev
B.ZH. Sakhiyev
MRMuratbay Ryskaliyev
Muratbay Ryskaliyev
SZSabit Zharylgapov
Sabit Zharylgapov
ADAgnieszka Dąbska
Agnieszka Dąbska
AMAinur Montayeva
Ainur Montayeva
A topical issue in the modernization of housing and communal services is increasing the energy efficiency of enclosing structures while maintaining the standard strength and durability of wall materials. The study aimed to investigate opportunities for the use of glass cullet and fly ash in the production of autoclaved silicate bricks to reduce their thermal conductivity. The tested characteristics included average density, the thermal conductivity coefficient, compressive and flexural strength, water absorption, and frost resistance. The introduction of glass powder and fly ash was found to consistently lower the average density of silicate bricks from 1,910–1,950 to 1,625–1,700 kg/m³ and the thermal conductivity from 0.88–0.91 to 0.52–0.54 W/(m•K). The optimal compositions (samples No. 2 and No. 3) reduced thermal conductivity by 25–30% compared to the control sample with compressive strength remaining above 17.5 MPa and frost resistance in the range of F27–F35. An analysis of microstructural and phase characteristics based on SEM and XRD data showed that the improvement of thermophysical properties was due to the formation of a finely porous structure and a mixed hydrate matrix containing tobermorite and an amorphous C–S–H phase. The results confirm the expedience of using glass cullet and fly ash to produce energy-efficient silicate bricks suitable for use in enclosing structures in the framework of modernizing the facilities of housing and community services, which will not require major changes to current production technologies.

16 September 2026 in Buildings
Verified
Journal Article
Open access
PDF file
AMAinur Montayeva
Ainur Montayeva
ADAgnieszka Dąbska
Agnieszka Dąbska
YAYergen Ashkei
Yergen Ashkei
GZGulnaz Zhakapbayeva
Gulnaz Zhakapbayeva
AIAkniyet Izbassar
Akniyet Izbassar
DMDaniyel Mikhailov
Daniyel Mikhailov
Early-stage selection of pile foundation systems is associated with considerable uncertainty due to limited site information and the need to consider multiple geotechnical, structural, and construction-related factors simultaneously. This study proposes a rule-based decision-support framework, named GeoSupport Decision Platform (GSDP), for transparent and systematic evaluation of pile foundation alternatives across varying engineering conditions. A multicriteria scoring procedure is introduced into the proposed framework to evaluate the recommended pile alternative for the application. The implemented procedure combines compatibility scores and weighting coefficients based on engineering judgement and related to soil type, groundwater conditions, frost depth, load level, vibration/noise restrictions, and site accessibility. The ranked pile alternative list, closely linked to the suitability scores, is an outcome of the framework. The applicability of the GSDP framework is illustrated through two case studies based on construction sites in Kokshetau and Astana, Kazakhstan, representing different geotechnical and construction conditions. For the Kokshetau construction site, the GSDP framework recommends driven piles with a suitability score of 0.975 as the most suitable foundation alternative, followed by bored piles and micropiles, with suitability scores of 0.905 and 0.845, respectively. In contrast, for the Astana case, bored/CFA piles are ranked first with a suitability score of 0.970, followed by micropiles (0.825) and driven piles (0.775). In both cases, the highest-ranked pile alternative corresponds to the pile foundation system adopted at the respective construction site. The results show that the framework generates transparent, interpretable recommendations through a weighted scoring procedure and provides brief explanations that align with the engineering solution chosen for the case study. The contrasting rankings, which demonstrate the ability of the framework to respond to site-specific conditions rather than systematically favoring a single pile type, indicate the GSDP’s practical engineering significance for the preliminary selection of pile foundations when site investigation data are limited.