Bin Luo

Dr. Bin Luo

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
XCXu Cao
Xu Cao
CWCaiyun Wang
Caiyun Wang
RLRan Lu
Ran Lu
YMYanting Mu
Yanting Mu
JHJiangqi Hu
Jiangqi Hu
SCSu Chen
Su Chen
This study aims to investigate the effects of graphene oxide-modified titanium dioxide nanotube (TNT-GO) coatings on the biological behavior of Schwann cells and to evaluate their potential applications in dental implant surface modification and peripheral nerve regeneration. Titanium dioxide nanotubes (TNTs) were prepared by anodic oxidation, and graphene oxide (GO) was deposited on their surfaces by electrochemical deposition. The surface morphology and physicochemical properties were characterized by scanning electron microscopy (SEM), Raman spectroscopy, atomic force microscopy, X-ray diffraction, and contact angle measurements. The viability, proliferation, and adhesion of Schwann cells were assessed by cell counting kit-8 assay, live/dead staining, and SEM observation. The expression levels of nerve growth factor (NGF) and glial cell line-derived neurotrophic factor (GDNF) were evaluated by immunofluorescence staining and real-time reverse-transcriptase polymerase chain reaction. The results indicated that TNT-GO surface significantly improved surface hydrophilicity and biocompatibility. Compared with the Ti and TNT groups, Schwann cells on TNT-GO surfaces exhibited enhanced proliferation, better spreading morphology, and significantly increased expression levels of NGF and GDNF. Overall, TNT-GO effectively promotes Schwann cell proliferation, adhesion, and neurotrophic factor secretion, suggesting its potential as a novel surface modification strategy to promote peri-implant nerve regeneration and improve osseoperception.

29 September 2026 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
QZQingshuo Zhan
Qingshuo Zhan
SLSirui Liu
Sirui Liu
SXSiyu Xie
Siyu Xie
JHJiangqi Hu
Jiangqi Hu
QPQian Pang
Qian Pang
QJQingsong Jiang
Qingsong Jiang
Titanium and its alloys are widely used in orthopedic and dental implants and bone repair scaffolds because of their mechanical properties, corrosion resistance, and biocompatibility. However, their bioinert surfaces may still show poor early osseointegration, bacterial infection, inflammatory imbalance, and limited long-term interfacial stability. Conventional surface modifications mainly change topography and chemistry, but provide limited simulation of the bone electrophysiological microenvironment. Piezoelectric materials convert physiological loading or external ultrasound into local electrical signals, offering a route to dynamically responsive titanium interfaces. This review summarizes piezoelectric material types, coating design, preparation methods, and biological effects on titanium surfaces. It discusses mechanisms related to osteogenic differentiation, osseointegration, antibacterial effects, infection control, and osteoimmune regulation. Piezoelectric coatings may affect membrane potential, ion channels, the cytoskeleton, cell adhesion, reactive oxygen species production, and macrophage function. Key translational challenges include signal decay in wet conditions, weak interfacial bonding, limited long-term stability, material safety concerns, lack of standardized preparation, and insufficient in vivo evaluation. Future studies should establish stable and biologically effective local electrical microenvironments and validate long-term safety in clinically relevant models.

Verified
Journal Article
Open access
PDF file
XCXu Cao
Xu Cao
JHJiangqi Hu
Jiangqi Hu
QPQian Pang
Qian Pang
QJQingsong Jiang
Qingsong Jiang
SCSu Chen
Su Chen
BLBin Luo
Bin Luo
The long-term stability of dental implants is limited by multiple factors, including peri-implant infection, impaired osseointegration, and poor soft tissue sealing. Compared with conventional passive surface modification strategies, piezoelectric materials can convert mechanical energy into local electrical signals under occlusal loading, cell traction, or ultrasonic stimulation. With the aid of defect engineering, heterostructure construction, and co-catalytic design, these materials can also induce the generation of reactive oxygen species and reactive nitrogen species, thereby enabling on-demand antibacterial activity. This review systematically summarizes the bioelectric basis of bone tissue and clarifies how piezoelectricity and piezocatalysis may be used in dental implant surface engineering. Their applications are discussed in terms of antibiofilm and antibacterial activity, osteogenesis and osseointegration, osteoimmunomodulation, soft tissue healing, and temporally programmed therapy. In addition, this review also discusses issues that remain unresolved, such as polymer-based composite systems, realistic activation windows, evaluation standards, device–material integration, and multi-omics validation. Overall, piezoelectric surface engineering is evolving from a single osteogenesis-oriented strategy into an integrated platform that coordinates infection control, immune remodeling, and osseointegration. However, the actual effectiveness of its clinical application still needs to be determined through more rigorous mechanism analysis, long-term stability assessment, biosafety assessment, and standardized preclinical research.