Xu Cao

Dr. Xu Cao

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
XCXu Cao
Xu Cao
KWKeyi Wu
Keyi Wu
CWCaiyun Wang
Caiyun Wang
YGYatong Guo
Yatong Guo
RLRan Lu
Ran Lu
SCSu Chen
Su Chen
Surface topography, protein adsorption, and the loading of coating materials can affect soft tissue sealing. Graphene oxide (GO) is a promising candidate for improving material surface functionalization to facilitate soft tissue integration between cells and biomaterials. In this study, TiO2 nanotubes (TNTs) were prepared by the anodization of Ti, and TNT-graphene oxide composites (TNT-GO) were prepared by subsequent electroplating. The aim of this study was to investigate the effect of TNTs and TNT-GO surface modifications on the behavior of human gingival fibroblasts (HGFs). Commercially pure Ti and TNTs were used as the control group, and the TNT-GO surface was used as the experimental group. Scanning electron microscopy, X-ray photoelectron spectroscopy, and X-ray diffraction were used to perform sample characterization. Cell adhesion, cell proliferation, cell immunofluorescence staining, a wound-healing assay, real-time reverse-transcriptase polymerase chain reaction (RT-PCR), and Western blotting showed that the proliferation, adhesion, migration, and adhesion-related relative gene expression of HGFs on TNT-GO were significantly enhanced compared to the control groups, which may be mediated by the activation of integrin β1 and the MAPK-Erk1/2 pathway. Our findings suggest that the biological reactivity of HGFs can be enhanced by the TNT-GO surface, thereby improving the soft tissue sealing ability.

5 June 2024 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
BZBaijin Zeng
Baijin Zeng
BLBin Luo
Bin Luo
JHJiangqi Hu
Jiangqi Hu
DMDan Meng
Dan Meng
JZJiebing Zhang
Jiebing Zhang
QJQingsong Jiang
Qingsong Jiang
Background: Margin designs and loading conditions can impact the mechanical characteristics and survival of endocrowns. Analyzing the stress distribution of endocrowns with various margin designs and loading conditions can provide evidence for their clinical application. Methods: Three finite element analysis models were established based on the margin designs: endocrown with a butt-joint type margin (E0), endocrown with a 90° shoulder (E90), and endocrown with a 135° shoulder (E135). The E0 group involved lowering the occlusal surface and preparing the pulp chamber. The E90 group created a 90° shoulder on the margin of model E0, measuring 1.5 mm high and 1 mm wide. The E135 group featured a 135° shoulder. The solids of the models were in fixed contact with each other, and the materials of tooth tissue and restoration were uniform, continuous, isotropic linear elasticity. Nine static loads were applied, with a total load of 225 N, and the maximum von Mises stresses and stress distribution were calculated for teeth and endocrowns with different margin designs. Results: Compared the stresses of different models under the same loading condition. In endocrowns, when the loading points were concentrated on the buccal side, the maximum von Mises stresses were E0 = E90 = E135, and when there was a lingual loading, they were E0 < E90 = E135. In enamel, the maximum von Mises stresses under all loading conditions were E0 > E90 > E135. In dentin, the maximum von Mises stresses of the three models were basically similar except for load2, load5 and load9. Compare the stresses of the same model under different loading conditions. In endocrowns, stresses were higher when lingual loading was present. In enamel and dentin, stresses were higher when loaded obliquely or unevenly. The stresses in the endocrowns were concentrated in the loading area. In enamel, stress concentration occurred at the cementoenamel junction. In particular, E90 and E135 also experienced stress concentration at the shoulder. In dentin, the stresses were mainly concentrated in the upper section of the tooth root. Conclusion: Stress distribution is similar among the three margin designs of endocrowns, but the shoulder-type designs, especially the 135° shoulder, exhibit reduced stress concentration.

1 January 2022 in Journal of Nanomaterials
Verified
Journal Article
Open access
PDF file
XCXu Cao
Xu Cao
RLRan Lu
Ran Lu
XWXin Wang
Xin Wang
CWCaiyun Wang
Caiyun Wang
YZYu Zhao
Yu Zhao
SCSu Chen
Su Chen
The immunomodulatory role of monocytes is essential for tissue healing and can influence the osseointegration of implanted materials. Properties such as the surface structure, hydrophilicity, and roughness of the implanted materials can modulate monocyte–macrophage function. In this study, we characterized material‐hydrogenated TiO2 nanotubes (H‐TNT) with superhydrophilic surfaces to investigate the effect of H‐TNT on macrophage polarization and osseointegration. H‐TNT were prepared by anodic oxidation and hydrogenation and used in the experimental group, while TNT and smooth pure Ti were employed in the control groups. RAW264.7 cells were selected to observe the immunomodulatory effect of these samples. The cell morphology was observed via scanning electron microscopy, and cytokine expression was detected using an enzyme‐linked immunosorbent assay and immunofluorescence staining. After 24 hr of cultivation, the macrophage‐conditioned medium was collected and used for indirect coculture with MC3T3‐E1 cells. The morphology of MC3T3‐E1 cells was observed using fluorescence staining. Cell adhesion and proliferation were measured using the Cell Counting Kit‐8 assay. Alkaline phosphatase activity measurement, alizarin red staining, calcium quantification, and reverse transcription polymerase chain reaction were performed to assess the osteogenic differentiation of MC3T3‐E1 cells. The results showed that H‐TNT promoted the M2‐type polarization of macrophages, which in turn influenced the adhesion, proliferation, and osteogenic differentiation of MC3T3‐E1 cells. These materials can serve as useful candidates for bone implants because they activate macrophages to produce a favorable osteoimmunomodulatory microenvironment.

Verified
Journal Article
Open access
PDF file
XCXu Cao
Xu Cao
JHJiangqi Hu
Jiangqi Hu
QPQian Pang
Qian Pang
QJQingsong Jiang
Qingsong Jiang
SCSu Chen
Su Chen
BLBin Luo
Bin Luo
The long-term stability of dental implants is limited by multiple factors, including peri-implant infection, impaired osseointegration, and poor soft tissue sealing. Compared with conventional passive surface modification strategies, piezoelectric materials can convert mechanical energy into local electrical signals under occlusal loading, cell traction, or ultrasonic stimulation. With the aid of defect engineering, heterostructure construction, and co-catalytic design, these materials can also induce the generation of reactive oxygen species and reactive nitrogen species, thereby enabling on-demand antibacterial activity. This review systematically summarizes the bioelectric basis of bone tissue and clarifies how piezoelectricity and piezocatalysis may be used in dental implant surface engineering. Their applications are discussed in terms of antibiofilm and antibacterial activity, osteogenesis and osseointegration, osteoimmunomodulation, soft tissue healing, and temporally programmed therapy. In addition, this review also discusses issues that remain unresolved, such as polymer-based composite systems, realistic activation windows, evaluation standards, device–material integration, and multi-omics validation. Overall, piezoelectric surface engineering is evolving from a single osteogenesis-oriented strategy into an integrated platform that coordinates infection control, immune remodeling, and osseointegration. However, the actual effectiveness of its clinical application still needs to be determined through more rigorous mechanism analysis, long-term stability assessment, biosafety assessment, and standardized preclinical research.

Verified
Journal Article
Open access
PDF file
XCXu Cao
Xu Cao
CWCaiyun Wang
Caiyun Wang
RLRan Lu
Ran Lu
YMYanting Mu
Yanting Mu
JHJiangqi Hu
Jiangqi Hu
SCSu Chen
Su Chen
This study aims to investigate the effects of graphene oxide-modified titanium dioxide nanotube (TNT-GO) coatings on the biological behavior of Schwann cells and to evaluate their potential applications in dental implant surface modification and peripheral nerve regeneration. Titanium dioxide nanotubes (TNTs) were prepared by anodic oxidation, and graphene oxide (GO) was deposited on their surfaces by electrochemical deposition. The surface morphology and physicochemical properties were characterized by scanning electron microscopy (SEM), Raman spectroscopy, atomic force microscopy, X-ray diffraction, and contact angle measurements. The viability, proliferation, and adhesion of Schwann cells were assessed by cell counting kit-8 assay, live/dead staining, and SEM observation. The expression levels of nerve growth factor (NGF) and glial cell line-derived neurotrophic factor (GDNF) were evaluated by immunofluorescence staining and real-time reverse-transcriptase polymerase chain reaction. The results indicated that TNT-GO surface significantly improved surface hydrophilicity and biocompatibility. Compared with the Ti and TNT groups, Schwann cells on TNT-GO surfaces exhibited enhanced proliferation, better spreading morphology, and significantly increased expression levels of NGF and GDNF. Overall, TNT-GO effectively promotes Schwann cell proliferation, adhesion, and neurotrophic factor secretion, suggesting its potential as a novel surface modification strategy to promote peri-implant nerve regeneration and improve osseoperception.

9 May 2024 in Physica Scripta
Verified
Journal Article
Open access
YMYanting Mu
Yanting Mu
XWXin Wang
Xin Wang
RLRan Lu
Ran Lu
CWCaiyun Wang
Caiyun Wang
XCXu Cao
Xu Cao
JZJian Zhou
Jian Zhou
The gingival epithelium plays a crucial role in achieving long-term stability of dental implants, and the hydrogenated TiO2 nanotubes with a superhydrophilic surface exhibit more excellent biological activity than pure titanium implants. However, the effects of the hydrogenated TiO2 nanotubes on human gingival epithelial cells remain unclear. Here, we fabricated hydrogenated TiO2 nanotubes using anodization and hydrogenation to investigate the adhesion of human gingival epithelial cells (HGEs) on structured surfaces in vitro. The topography, roughness, and wettability of three sample types—titanium (Ti), TiO2 nanotubes (TNTs), and hydrogenated TiO2 nanotubes (H2-TNTs)—were characterized. To evaluate cell adhesion, the HGEs were co-cultured with these specimens. This allowed for the examination of both the adhesion morphology and the number of cells adhering to each material’s surface. Expression levels of genes and proteins related to cell adhesion were also assessed. H2-TNTs demonstrated nanoscale topography similar to TNTs in terms of diameter and height and maintained a superhydrophilic surface (with a static water contact angle of < 5°). The number of HGEs adhering to H2-TNTs was notably higher. Furthermore, HGEs on H2-TNTs displayed a more stretched morphology in comparison to the other two groups. Notably, the expression levels of adhesion-related genes and proteins in H2-TNTs surpassed those of the other two groups. Hence superhydrophilic H2-TNTs significantly enhance the adhesion ability of HGEs on the material surface.