Kouba Marie Lucia Yapi

Mrs. Kouba Marie Lucia Yapi


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2018 in Energies
Verified
Journal Article
Open access
PDF file
KKKakou D. Kouassi
Kakou D. Kouassi
Issouf FofanaIssouf Fofana
Issouf Fofana
LCLadji Cissé
Ladji Cissé
YHYazid Hadjadj
Yazid Hadjadj
KYKouba Marie Lucia Yapi
Kouba Marie Lucia Yapi
KDK. Ambroise Diby
K. Ambroise Diby
Aging of a power transformer’s insulation system produces carboxylic acids. These acids—acetic, formic and levulinic—are absorbed by the paper insulating material, thus accelerating the degradation of the whole insulation system. In this contribution, the effect of these acids on the aging of oil-impregnated paper insulation used in power transformer is reported. A laboratory aging experiment considering different concentrations of these three acids was performed to assess their effect on the insulation system’s degradation. Each acid was individually mixed with virgin oil, and a mixture of acids was also blended with oil. The paper’s degradation was assessed by the degree of polymerization (DPv). It was found that the DPv of paper aged with formic acid decreased much faster in comparison to the other acids.

6 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
Issouf FofanaIssouf Fofana
Issouf Fofana
Janvier Sylvestre N'choJanvier Sylvestre N'cho
Janvier Sylvestre N'cho
ABAmidou Betie
Amidou Betie
EHEpiphane Hounton
Epiphane Hounton
Meghnefi FethiMeghnefi Fethi
Meghnefi Fethi
KYKouba Marie Lucia Yapi
Kouba Marie Lucia Yapi
Among the main causes of outdoor insulation failures is their poor specifications in terms of leakage distances. This happens when the selected criteria are unable to cope with all the stresses imposed by the changes in environmental pollutions. Therefore, it is important for utilities to fully understand the actual pollution characteristics of the service environment in which the insulators are operating. In this paper, the pollution severity and performance of some 13.2 kV ceramic insulators, sampled in different areas of a Canadian aluminum factory, are assessed. The investigations were performed taking into account the influence of air humidity. Various characteristics were investigated to assess the pollution levels of the insulators, such as equivalent salt deposit density (ESDD) and non-soluble deposit density (NSDD), surface resistance, and leakage current characteristics (density, 3rd harmonic amplitude, and phase). It was witnessed that the insulators, collected around the factory, were much more polluted in comparison to the initial expectation. The pollution level should not be considered static due to the environmental parameters’ dynamics. Lessons to learn: the reliability of an electrical grid is dependent on components whose own reliability is strongly affected by external factors, of which there is often a poor awareness. If care is not taken to re-evaluate the post-installation pollution levels of the insulators, the light may simply turn out!