Haitao Li

Prof. Dr. Haitao Li


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2020 in International Journal of Precision Engineering and Manufacturing
Verified
Journal Article
Closed access
PDF file
JWJindong Wang
Jindong Wang
CCCong Cheng
Cong Cheng
LHLi Haitao
Li Haitao

26 March 2019 in International Journal of Precision Engineering and Manufacturing
Verified
Journal Article
Closed access
PDF file
JWJin-Dong Wang
Jin-Dong Wang
QWQing-Jie Wang
Qing-Jie Wang
LHLi Haitao
Li Haitao

25 October 2016 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
LHLi Haitao
Li Haitao
GJGuo Junjie
Guo Junjie
DYDeng Yufen
Deng Yufen
WJWang Jindong
Wang Jindong
HXHe Xinrong
He Xinrong
The laser tracker is an effective instrument for measuring 3D relative displacement in a work volume because its attitude can be freely changed. This paper presents a novel principle to realize the precise calibration of a numerical control (NC) machine tool accurately and quickly; this is the 'pose measurement principle', for measuring errors. We also introduce an algorithm for identifying geometric deviations. A NC precise table mounted on a motion axis and a laser tracker are used for the coordinate determination of three fixed points to obtain the pose information of each motion axis, then calculate the pose deviations, and finally identify all the errors. For the error identification, first, according to the definition of geometric errors, we extend the concept of pose deviations, and represent the six geometric errors using a position deviation vector and attitude deviation vector. Next, we geometrically identify the three angular errors and linear errors in order; the error mathematical model for the linear axis and rotary axis are developed, respectively. Moreover, the validity of the calibration algorithm for the base station, measuring points and identification of errors are confirmed by simulations. In the end, the proposed method is applied to a three-axis NC milling machine tool and a rotary table, and then the geometric deviations are identified successfully in 3 h and 2.5 h, respectively. Comparative experiments by means of other instruments also agree well with the proposed method. Thus, the proposed method can be applied to the measurement of the multi-axis machine tool.

2 September 2025 in Measurement Science and Technology
Verified
Journal Article
Closed access
LHLi Haitao
Li Haitao
XJXiaoning Jing
Xiaoning Jing
YWYawen Wang
Yawen Wang
LYLijun Yang
Lijun Yang
HLHan Li
Han Li
XGXinlei Guo
Xinlei Guo
In view of the existing three-dimensional laser tracking measurement system for detecting machine tool geometric accuracy, the strong dependence on the coordinate system, the difficulty in tracing the measurement results, and the high equipment cost, this study proposes a new low-cost, high-precision three-dimensional hybrid laser-ballbar measurement system and a supporting measurement method. The system comprises a three-dimensional laser dual ballbar and a reference station calibrator. The dual ballbar integrates the high-precision attributes of a laser interferometer with the dynamic measurement capabilities of a conventional ballbar. The base station calibrator is used as a physical reference to evaluate system errors and trace measurement data. The proposed method realizes the measurement and evaluation of three-dimensional dynamic geometric errors and has good versatility. This paper designs and carries out measurement experiments on the positioning error, straightness error and angular error (pitch and yaw) in the X-axis and Y-axis directions and compares and analyzes them with the measurement results of the laser interferometer. The experimental findings indicate that, over a 300 mm measurement range, the X-axis exhibits a maximum positioning deviation of 1.8 μm, with repeatability exceeding 1.51 μm and an expanded uncertainty between 2.82 and 3.98 μm (k = 2). The straightness deviation remains under 2.9 μm, while the peak angular error is 3.6 μrad. For the Y-axis, the maximum positioning deviation reaches 2.3 μm, repeatability is better than 1.5 μm, and the expanded uncertainty lies between 3.14 and 3.88 μm (k = 2). The straightness deviation does not exceed 3.7 μm, and the angular error peaks at 4.6 μrad. These outcomes validate the precision and reliability of the developed measurement system in assessing geometric errors of machine tools, highlighting its promising applicability in engineering contexts.

28 May 2026 in Machines
Verified
Journal Article
Open access
PDF file
LHLi Haitao
Li Haitao
YWYuanbiao Wang
Yuanbiao Wang
YWYawen Wang
Yawen Wang
YYYunlong Yu
Yunlong Yu
ZWZehao Wang
Zehao Wang
MZMeng Zhang
Meng Zhang
In the measurement of volumetric errors in CNC machine tools using multi-station laser tracking technology, the coordinate calibration accuracy of external measurement base stations is a key factor determining the system’s final accuracy. Traditional calibration approaches typically use the commanded positions of the machine tool directly to inversely determine base station coordinates, which results in strong coupling between inherent geometric errors and base station parameters. Consequently, the measurement accuracy cannot be properly evaluated, and metrological traceability of the results remains difficult to achieve. To address this issue, this paper proposes a novel calibration principle based on an independent external physical standard and develops a base station calibrator independently. This device employs a precision turntable, G5-grade precision spheres, and electromagnet groups to construct an equivalent target with four feature points at the spindle end. Verified by a high-precision coordinate measuring machine (CMM), the maximum difference in repeated calibrations of the device is 1.4 µm, indicating its excellent positioning repeatability. The calibrator was further applied to measure the positioning errors of a CNC milling machine, and comparative experiments were performed with a Renishaw XL-80 laser interferometer. The results indicate that the error variation trends obtained from the two measurement principles are highly consistent. In both the X-axis and Y-axis directions, the maximum deviations of linear errors are controlled within 3.7 µm, while the maximum deviations of angular errors remain within 4.6 µrad. Furthermore, the reliability of the system data was confirmed through an uncertainty analysis. The external physical standard developed in this study ensures that base station calibration accuracy is not affected by the inherent errors of the machine tool, providing a novel and reliable scheme for high-precision calibration and metrological traceability of machine tool spatial errors.

22 May 2026 in Aerospace
Verified
Journal Article
Open access
PDF file
LHLi Haitao
Li Haitao
YBYunhong Bai
Yunhong Bai
YWYawen Wang
Yawen Wang
MZMengyang Zhang
Mengyang Zhang
YZYikang Zhang
Yikang Zhang
JLJie Li
Jie Li
Impinging injectors are extensively utilized in liquid rocket engines, characterized by a large number of paired inclined injection orifices. The diameter and axis alignment deviation of these orifices directly influence propellant flow distribution, atomization and mixing behavior, and engine operational stability. To address the challenges associated with micro-sized orifices, inclined axes, large quantities, spatial intersection, and the low detection efficiency of conventional approaches, this paper proposes a dual-line laser 3D point cloud reconstruction-based method for measuring the diameter and impact alignment deviation of injector orifices. A dual-line laser measurement system is established to capture surface point clouds on both sides of the orifice inlets. Through system calibration and point cloud registration, the 3D point cloud data of the injector orifices within a unified coordinate system are reconstructed. Cross-sectional mapping, boundary extraction, and geometric fitting techniques are applied to determine the diameter and axis parameters of the orifices, and the spatial alignment deviation of paired orifices is subsequently calculated. To validate the feasibility of the proposed method, experimental investigation is conducted on test specimens with both 8 pairs of Φ2 mm through-holes and Φ0.5 mm micro-orifices. For the Φ2 mm specimen, the diameter measurement results are compared with industrial computed tomography (CT) data, while the alignment deviation results are verified using a combination of pin gauges and coordinate measuring machine (CMM) measurements. For the Φ0.5 mm micro-orifices, both diameter and alignment deviation results are verified using a 3D coaxial line confocal sensor. After system calibration, the fitting residuals of three Φ8 mm standard spheres are all maintained within 0.08 mm. The diameter measurement results of 8 selected Φ2 mm orifices show good overall agreement with industrial CT data: the maximum absolute deviation is 22 μm, the average absolute deviation is 15 μm, the maximum relative error is 1.09%, and the average relative error is 0.74%. The diameter and alignment deviation results of Φ0.5 mm micro-orifices show good consistency with the 3D coaxial line confocal sensor: the maximum absolute deviation is 13 μm for diameter and 0.047° for alignment deviation, with maximum relative errors of 2.41% and 0.058%, respectively. The alignment deviation results of 8 pairs of Φ2 mm orifices indicate that the proposed dual-line laser method is generally consistent with the combined pin gauge and CMM approach: the maximum absolute deviation is 0.170°, the average absolute deviation is 0.125%, the maximum relative error is 0.284%, and the average relative error is 0.125%. The results demonstrate that the proposed method enables non-contact and high-efficiency measurement of the diameter and alignment angle of injector orifices in impinging injectors for both conventional Φ2 mm orifices and micro Φ0.5 mm orifices, with high measurement accuracy and promising engineering application potential, thereby providing a new technical approach for the geometric parameter inspection of multi-scale micro-injection orifices.