Jie Li

Dr. Jie Li

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Zhikang LiZhikang Li
Zhikang Li
JLJiazhu Li
Jiazhu Li
YZYihe Zhao
Yihe Zhao
ZLZixuan Li
Zixuan Li
XSXuan Shi
Xuan Shi
Libo ZhaoLibo Zhao
Libo Zhao
Axial stress monitoring of bolts is significant to various engineering structures and machines because it can assist their reliable and durable operation, and prevent major failures and safety accidents. Among various sensing technologies, ultrasound holds prominent advantages in accuracy, noninvasiveness, non-destructive testing, etc. However, current ultrasonic technique predominantly relies on conventional bulk-PZT ultrasonic transducers, which suffer large size, high-power consumption, and inferior integration with ICs, hindering real-time and long-term monitoring and application in small bolts. This paper highlights the prospect of piezoelectric micromachined ultrasonic transducers (PMUT) in aforementioned application situations based on acoustic elastic effects and bolt length variations induced time differences. The corresponding theories for the relationship between the time difference and the stress are validated by finite element methods. A specific PMUTs with inner circular and outer annular arrays and optimized ultrasound frequencies were proposed to improve sensing performance. As such, the axial stress variation in a steel bolt with a nominal diameter as small as 6 mm is successfully monitored using our fabricated PMUTs chip with a resonant frequency of 850 kHz. Excellent linearity (≥0.998) between the ToF difference and applied stress and a high accuracy of less than 3% are demonstrated. Further, experimental testing of bolt stress under different practical conditions, such as bolt sizes, materials, and connection types validates the performance robustness and widespread applicability of our proposed PMUT-based ultrasonic stress sensing technique.

23 January 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Zhikang LiZhikang Li
Zhikang Li
JYJiawei Yuan
Jiawei Yuan
JLJie Li
Jie Li
ZLZixuan Li
Zixuan Li
YZYihe Zhao
Yihe Zhao
Libo ZhaoLibo Zhao
Libo Zhao
Capacitive micromechanical ultrasonic transducers (CMUTs) have widespread applications in ultrasonic imaging, therapeutic treatment, and underwater applications. Reasonable design of their array structures essentially determines the performance in aforementioned applications. However, there is a lack of a systematic investigation on the design strategies and effects of structure parameters of CMUTs arrays, significantly impeding their performance improvement. This paper constructs explicit and accurate analytical expressions for the main performances of CMUTs arrays in immersion by introducing the accurate distributed membrane deflection. Based on these theories, the influence laws of the aforementioned structure parameters on the CMUTs array performances are analyzed and summarized in detail, including the transmitting power, receiving sensitivity, focal length, beamwidth, etc. These theories and array performance variation rules are well validated by finite element method (FEM) simulations and experiment results of our fabricated CMUTs chips. It is demonstrated by the FEM simulation that, under specific array structural parameters, the fill factor has a significant improvement effect on CMUTs bandwidth (up to 173%). The multi arm spiral array and ring-shape array reduce the sidelobe level (62% less than that of conventional square arrays) and improve the transmitting power and receiving sensitivity (35% and 33% larger than that of conventional circular arrays), respectively. Based on these, CMUTs array design and optimization strategies are provided for typical ultrasonic applications. This study provides a theoretical basis for the design and application of CMUTs arrays in immersion, which will accelerate the development of CMUTs devices.

21 May 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Zhikang LiZhikang Li
Zhikang Li
SQShaohui Qin
Shaohui Qin
JYJiawei Yuan
Jiawei Yuan
JLJie Li
Jie Li
YZYihe Zhao
Yihe Zhao
Libo ZhaoLibo Zhao
Libo Zhao
Low-voltage, high-performance capacitive micromachined ultrasonic transducers (CMUTs) are in urgent demand for portable ultrasound imaging and human-machine interfaces. However, most existing CMUTs exhibit superior comprehensive performance due to conflicting requirements in their structural design, which constrains their practical applications. This paper proposes a novel CMUT with T-shape cavities to achieve synergistic enhancement of multiple key performances by harnessing the electrostatic stiffness softening effect (ESSE). The unique T-shape cavity design features a smaller electrode distance in the peripheral area compared to the central area, which produces a higher electric field intensity and thus a larger membrane stiffness drop in the peripheral area of the vibrating membrane through the corresponding enhancement of ESSE. This special stiffness adjustment strategy ultimately enables the entire membrane to produce piston-like deformation, significantly improving both the maximum and average membrane deformation, and contributing to enhancements in operation voltage, transmitting and receiving sensitivities, electromechanical coupling coefficient, etc. The finite element method (FEM) is employed to investigate the device’s performance. Compared to conventional CMUTs, T-CMUTs reduce collapse voltage by 36.2%, with transmitting/receiving sensitivities and electromechanical coupling coefficient improved by 56.1%, 62.6%, and 76.0% under the same bias ratios; furthermore, these parameters improve by 371.0%, 516.0%, and 618.4% respectively at same bias voltages. An analysis of the stress distribution of the membrane further verifies the underlying mechanism of the T-shape cavity in enhancing device performance. Additionally, the foreseeable simple process and feasibility in consistent fabrication endow the proposed CMUTs with significant potential for practical application.

7 October 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HWHao Wu
Hao Wu
YLYang Liu
Yang Liu
HHHongqian Huang
Hongqian Huang
JLJie Li
Jie Li
QLQijing Lin
Qijing Lin
SLShengchao Liu
Shengchao Liu
A safe and reliable autonomous vehicle system depends largely on accurate location of obstacles in the environment, and precise calibration between LiDAR and camera is a prerequisite for multi-sensor fusion. However, calibration with target is laborious and time-consuming. In addition, the calibrated sensors may drift due to some factors such as the turbulence of the vehicle while the vehicle is in motion, which will cause the accumulation of errors and thus affect the driving. To solve these problems, a novel method is proposed to solve the extrinsic parameters of LiDAR and camera in road scenes. Thus, a feature extractor is constructed to extract lane and vehicle semantics from a pair of point clouds and image firstly, and then an objective function is maximized by an optimizer based on the initial extrinsic parameters. Because lane lines and vehicles on the road are complex, a lot of experiments on the KITTI dataset are conducted. The experimental results quantitatively and qualitatively demonstrate the accuracy and robustness of this method.

31 December 2024 in Measurement
Verified
Journal Article
Closed access
JLJie Li
Jie Li
ZXZhaohui Xiao
Zhaohui Xiao
ZWZutang Wu
Zutang Wu
KSKuiwei Shi
Kuiwei Shi
Zhikang LiZhikang Li
Zhikang Li
LZLibo Zhao
Libo Zhao

21 October 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JLJie Li
Jie Li
ZWZutang Wu
Zutang Wu
JLJin Li
Jin Li
ZXZhaohui Xiao
Zhaohui Xiao
Zhikang LiZhikang Li
Zhikang Li
Libo ZhaoLibo Zhao
Libo Zhao
The equivalent circuit is a commonly used tool for performance analysis during CMUT design and optimization. In this study, the immersion equivalent circuit model of square CMUT array is established for the first time. Using this model, the vibration, electrical, and acoustic characteristics of square CMUTs can be rapidly analyzed. Consequently, it can replace the time-consuming finite element model for design and optimization. For comparison with the equivalent circuit model presented in this paper, the finite element model of the square CMUT array was established by COMSOL 6.0a. The theoretical calculation results of the equivalent circuit model are highly consistent with the FEM results. Finally, a 28×28 CMUT array composed of square cells was fabricated using the wafer bonding process, and its vibration and impedance characteristics were tested using a Laser Doppler Vibrometer and an impedance analyzer. All experimental results well verified the accuracy of the proposed equivalent circuit models.