Gemma Sánchez-Antón

Prof. Gemma Sánchez-Antón


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
IGIsabel M. Gomez-Gonzalez
Isabel M. Gomez-Gonzalez
JCJuan Antonio Castro-Garcia
Juan Antonio Castro-Garcia
Manuel Merino-MongeManuel Merino-Monge
Manuel Merino-Monge
GSGemma Sánchez-Antón
Gemma Sánchez-Antón
FHFoad Hamidi
Foad Hamidi
AMAlberto J. Molina-Cantero
Alberto J. Molina-Cantero
Background: The protocol described in this paper is part of a research project coordinated between three Spanish universities, where a technology aimed at improving the quality of life of people with cerebral palsy will be developed. Part of the proposed technology will consist of an interface and a series of applications to increase motivation for daily physical activity. The basis of these developments is the measurement of the emotional state of the subjects. Methods: The experimental protocol is designed with two research objectives, on the one hand to identify the emotional state through physiological signals, and on the other to determine whether music can be a motivating factor to promote physical activity. It is specifically designed for subjects with cerebral palsy, taking into account the special characteristics of this population. These are people with whom it is difficult to use questionnaires to have a basis to contrast with the measured physiological signals, so measurements must be taken in carefully chosen daily-life situations. Discussion: We hope our findings show which physiological parameters are the most robust to measure the emotional state and how to design rehabilitation and physical activity promotion routines that are motivating, in addition to being able to avoid risk factors during the performance of these routines. Trial registration: NCT05621057.

23 January 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
IGIsabel M. Gomez-Gonzalez
Isabel M. Gomez-Gonzalez
JCJuan Antonio Castro-Garcia
Juan Antonio Castro-Garcia
Manuel Merino-MongeManuel Merino-Monge
Manuel Merino-Monge
GSGemma Sánchez-Antón
Gemma Sánchez-Antón
FHFoad Hamidi
Foad Hamidi
AMAlberto J. Molina-Cantero
Alberto J. Molina-Cantero
Background: The protocol described in this paper is part of a research project coordinated 1 between three Spanish universities where a technology aimed at improving the quality of life of 2 people suffering from cerebral palsy will be developed. Part of the technology developed will consist 3 of developing an interface and a series of applications to increase motivation for daily physical activity. 4 The basis of these developments is based on the measurement of the emotional state of the subjects. 5 Methods: The experimental protocol is designed with two objectives, on the one hand to identify the 6 emotional state through physiological signals, and on the other to determine whether music can be 7 a motivating factor to promote physical activity. It has been specifically designed for subjects with 8 cerebral palsy taking into account the special characteristics of this population. These are people with 9 whom it is difficult to use questionnaires to have a basis to contrast with the measured physiological 10 signals, so measurements must be taken in carefully chosen daily life situations Discussion: As results 11 we hope to obtain which physiological parameters are the most robust to measure the emotional state 12 and how to design rehabilitation and physical activity promotion routines that are motivating, in 13 addition to being able to avoid risk factors during the performance of these routines. Trial registration: 14 NCT05621057. https://clinicaltrials.gov/ct2/show/NCT05621057

14 April 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Manuel Merino-MongeManuel Merino-Monge
Manuel Merino-Monge
CLClara Lebrato-Vázquez
Clara Lebrato-Vázquez
JCJuan Antonio Castro-Garcia
Juan Antonio Castro-Garcia
GSGemma Sánchez-Antón
Gemma Sánchez-Antón
AMAlberto J. Molina-Cantero
Alberto J. Molina-Cantero
(1) Background: Heartbeat detection from electrocardiogram (ECG) and photoplethysmograph (PPG) signals is widely used in wearable devices for health monitoring, fitness tracking, and stress assessment. While numerous methods have been proposed, their practical suitability depends not only on accuracy but also on computational and memory constraints inherent to resource-limited systems. (2) Methods: A scoping review of 52 studies published between 2017 and 2024 was conducted, covering time-domain, frequency-domain, matrix-based, and machine learning approaches. The methods were evaluated according to estimation accuracy, computational complexity, memory footprint, and suitability for on-device implementation. (3) Results: Time-domain peak detection methods consistently provide high accuracy (minimum of 79.25%, maximum of 99.96%, and median ≥99.69%) for ECG and reliable heart rate estimation for PPG with linear computational complexity, low memory requirements and low energy consumption. Frequency-domain approaches are suitable for average heart rate estimation from PPG but do not preserve inter-beat intervals (error range of [1.07, 6.4] beats per minute (BPM)). Matrix-based and machine learning methods often entail higher computational cost without proportional performance gains in wearable contexts (error range of [1.07, 6.4] BPM for PPG signals; accuracy in range of [95.4, 99.96]% for ECG). (4) Conclusions: Lightweight signal-processing techniques offer the most favorable trade-off between accuracy and efficiency for wearable implementations, whereas computationally intensive approaches are better suited for edge- or cloud-based processing.