Heoung-Jae Chun

Prof. Heoung-Jae Chun

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2002 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
HCHeoung-Jae Chun
Heoung-Jae Chun
SCS.‐Y. Cheong
S.‐Y. Cheong
JHJ.‐H. Han
J.‐H. Han
SHS.‐J. Heo
S.‐J. Heo
JCJ.‐P. Chung
J.‐P. Chung
MKM.‐H. Kim
M.‐H. Kim

11 February 2005 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
HCHeoung-Jae Chun
Heoung-Jae Chun
DPD.‐N. Park
D.‐N. Park
CHC.‐H. Han
C.‐H. Han
SHS.‐J. Heo
S.‐J. Heo
MHM.‐S. Heo
M.‐S. Heo
JKJ.‐Y. Koak
J.‐Y. Koak

27 December 2022 in Biomolecules
Verified
Journal Article
Open access
PDF file
MKMoon Sung Kang
Moon Sung Kang
JJJinju Jang
Jinju Jang
HJHyo Jung Jo
Hyo Jung Jo
WKWon-Hyeon Kim
Won-Hyeon Kim
Bongju KIMBongju KIM
Bongju KIM
Dong-Wook HanDong-Wook Han
Dong-Wook Han
Three-dimensional (3D) bioprinted skin equivalents are highlighted as the new gold standard for alternative models to animal testing, as well as full-thickness wound healing. In this review, we focus on the advances and innovations of 3D bioprinting skin for skin regeneration, within the last five years. After a brief introduction to skin anatomy, 3D bioprinting methods and the remarkable features of recent studies are classified as advances in materials, structures, and functions. We will discuss several ways to improve the clinical potential of 3D bioprinted skin, with state-of-the-art printing technology and novel biomaterials. After the breakthrough in the bottleneck of the current studies, highly developed skin can be fabricated, comprising stratified epidermis, dermis, and hypodermis with blood vessels, nerves, muscles, and skin appendages. We hope that this review will be priming water for future research and clinical applications, that will guide us to break new ground for the next generation of skin regeneration.

1 September 2014 in Journal of Endodontics
Verified
Journal Article
Closed access
YJYoungjune Jang
Youngjune Jang
HHHyoung-Taek Hong
Hyoung-Taek Hong
BRByoung-Duck Roh
Byoung-Duck Roh
HCHeoung-Jae Chun
Heoung-Jae Chun

15 April 2016 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
KKKyoung‐Tak Kang
Kyoung‐Tak Kang
SKSung-Hwan Kim
Sung-Hwan Kim
JSJuhyun Son
Juhyun Son
YLYoung Han Lee
Young Han Lee
SKShinil Kim
Shinil Kim
HCHeoung-Jae Chun
Heoung-Jae Chun

16 July 2019 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
YKYong Gon Koh
Yong Gon Koh
JLJin-Ah Lee
Jin-Ah Lee
HLHwa-Yong Lee
Hwa-Yong Lee
HCHeoung-Jae Chun
Heoung-Jae Chun
HKHyo-Jeong Kim
Hyo-Jeong Kim
KKKyoung-Tak Kang
Kyoung-Tak Kang
High tibial osteotomy (HTO) is a common treatment for moderate osteoarthritis of the medial compartment in the knee joint by the translation of the force center toward the lateral compartment. However, the stability of a short plate such as Puddu used in this procedure was not as effective as other long plates such as Tomofix. No previous studies have used a rigorous and systematic design optimization method to determine the optimal shape of short HTO plate. Therefore, the purpose of this study is to evaluate the improved biomechanical stability of a short HTO plate by using design optimization and finite element (FE) analysis. A FE model of HTO was subjected to physiological and surgical loads in the tibia. Taguchi-style L27 orthogonal arrays were used to identify the most significant factors for optimizing the design parameters. The optimal design variables were calculated using the nondominated sorting genetic algorithm II. Plate and bone stresses and wedge micromotions in the initial and optimized designs were chosen as the comparison indices. Optimal designed HTO plate showed the decreased micromotions over the initial HTO plate with enhanced plate stability. In addition, increased bone stress and decreased plate stress supported the positive effect on stress shielding compared to initial HTO plate design. The results yielded a new short HTO design while demonstrating the feasibility of design optimization and potential improvements to biomechanical stability in HTO design. The newly developed short HTO plate throughout the optimization and computational simulation showed the improved biomechanical effect as good as the golden standard, TomoFix, does. This study showed that plate design has a strong influence on the stability after HTO. This study demonstrated that the optimized short plates had low stress shielding effect and less micromotion because of its improvement in biomechanical performances. Our result showed that design optimization is an effective tool for HTO plate design. This information can aid future developments in HTO plate design and can be expanded to other implant designs.