The development of successful scaffolds for bone tissue engineering requires concurrent engineering that combines different research fields. In previous studies, phenomenological computational models predicted the mechanical properties of a scaffold in a simple loading condition using the mechano-regulation theory. Therefore, the aim of this study is to predict the mechanical properties of an optimum scaffold required for cartilage regeneration using three-dimensional knee joint developed from medical imaging and mechano-regulation theory. It was predicted that the scaffold with optimal mechanical properties would result in greater amounts of cartilage tissue formation than without a scaffold. The results demonstrated the ability of the algorithms to design optimized scaffolds with target properties and confirmed the applicability of set techniques for bone tissue engineering. The scaffolds were optimized to suit the site-specific loading requirements, and the results reveal a new approach for computational simulations in tissue engineering.
(1) Background: Although knee arthroplasty or knee replacement is already an effective clinical treatment, it continues to undergo clinical and biomechanical improvements. For an increasing number of conditions, prosthesis based on an individual patient’s anatomy is a promising treatment. The aims of this review were to evaluate the clinical and biomechanical efficacy of patient-specific knee prosthesis, explore its future direction, and summarize any published comparative studies. (2) Methods: We searched the PubMed, MEDLINE, Embase, and Scopus databases for articles published prior to 1 February 2020, with the keywords “customized knee prosthesis” and “patient-specific knee prosthesis”. We excluded patient-specific instrument techniques. (3) Results: Fifty-seven articles met the inclusion criteria. In general, clinical improvement was greater with a patient-specific knee prosthesis than with a conventional knee prosthesis. In addition, patient-specific prosthesis showed improved biomechanical effect than conventional prosthesis. However, in one study, patient-specific unicompartmental knee arthroplasty showed a relatively high rate of aseptic loosening, particularly femoral component loosening, in the short- to medium-term follow-up. (4) Conclusions: A patient-specific prosthesis provides a more accurate resection and fit of components, yields significant postoperative improvements, and exhibits a high level of patient satisfaction over the short to medium term compared with a conventional prosthesis. However, the tibial insert design of the current patient-specific knee prosthesis does not follow the tibial plateau curvature.
16 July 2019 in Journal of Orthopaedic Surgery and Research
High tibial osteotomy (HTO) is a common treatment for moderate osteoarthritis of the medial compartment in the knee joint by the translation of the force center toward the lateral compartment. However, the stability of a short plate such as Puddu used in this procedure was not as effective as other long plates such as Tomofix. No previous studies have used a rigorous and systematic design optimization method to determine the optimal shape of short HTO plate. Therefore, the purpose of this study is to evaluate the improved biomechanical stability of a short HTO plate by using design optimization and finite element (FE) analysis. A FE model of HTO was subjected to physiological and surgical loads in the tibia. Taguchi-style L27 orthogonal arrays were used to identify the most significant factors for optimizing the design parameters. The optimal design variables were calculated using the nondominated sorting genetic algorithm II. Plate and bone stresses and wedge micromotions in the initial and optimized designs were chosen as the comparison indices. Optimal designed HTO plate showed the decreased micromotions over the initial HTO plate with enhanced plate stability. In addition, increased bone stress and decreased plate stress supported the positive effect on stress shielding compared to initial HTO plate design. The results yielded a new short HTO design while demonstrating the feasibility of design optimization and potential improvements to biomechanical stability in HTO design. The newly developed short HTO plate throughout the optimization and computational simulation showed the improved biomechanical effect as good as the golden standard, TomoFix, does. This study showed that plate design has a strong influence on the stability after HTO. This study demonstrated that the optimized short plates had low stress shielding effect and less micromotion because of its improvement in biomechanical performances. Our result showed that design optimization is an effective tool for HTO plate design. This information can aid future developments in HTO plate design and can be expanded to other implant designs.
21 February 2020 in Journal of Orthopaedic Surgery and Research
Background: This study aimed to investigate the biomechanical effect on the Takeuchi classification of lateral hinge fracture (LHF) after an opening wedge high tibial osteotomy (HTO).Methods: We performed an FE simulation for type I, type II, and type III in accordance with the Takeuchi classification. The stresses on the bone and plate, wedge micromotion, and forces on ligaments were evaluated to investigate stress-shielding effect, plate stability, and biomechanical change, respectively, in three different types of LHF HTO and with the HTO without LHF model (non-LHF) models.Results: The greatest stress-shielding effect and wedge micromotion were observed in type II LHF (distal portion fracture). The type II and type III (lateral plateau fracture) models exhibited a reduction in PCL force and an increase in ACL force compared with the HTO without LHF model. However, the type I (osteotomy line fracture) and HTO without LHF models did not exhibit a significant biomechanical effect. This study demonstrates that Takeuchi type II and type III LHF models provide unstable structures compared with the type I and HTO without LHF models.Conclusions: HTO should be performed while considering a medial opening wedge HTO to avoid a type II and type III LHF as a potential complication.
Objectives: Unicompartmental knee arthroplasty (UKA) is an alternative to total knee arthroplasty for patients who require treatment of single-compartment osteoarthritis, especially for young patients. To satisfy this requirement, new patient-specific prosthetic designs have been introduced. The patient-specific UKA is designed on the basis of data from preoperative medical images. In general, knee implant design with increased conformity has been developed to provide lower contact stress and reduced wear on the tibial insert compared with flat knee designs. The different tibiofemoral conformity may provide designers the opportunity to address both wear and kinematic design goals simultaneously. The aim of this study was to evaluate wear prediction with respect to tibiofemoral conformity design in patient-specific UKA under gait loading conditions by using a previously validated computational wear method.Methods: Three designs with different conformities were developed with the same femoral component: a flat design normally used in fixed-bearing UKA, a tibia plateau anatomy mimetic (AM) design, and an increased conforming design. We investigated the kinematics, contact stress, contact area, wear rate, and volumetric wear of the three different tibial insert designs.Results: Conforming increased design showed a lower contact stress and increased contact area. In addition, increased conformity resulted in a reduction of the wear rate and volumetric wear. However, the increased conformity design showed limited kinematics.Conclusion: Our results indicated that increased conformity provided improvements in wear but resulted in limited kinematics. Therefore, increased conformity should be avoided in fixed-bearing patient-specific UKA design. We recommend a flat or plateau AM tibial insert design in patient-specific UKA. Cite this article: Y-G. Koh, K-M. Park, H-Y. Lee, K-T. Kang. Influence of tibiofemoral congruency design on the wear of patient-specific unicompartmental knee arthroplasty using finite element analysis. Bone Joint Res 2019;8:156–164. DOI: 10.1302/2046-3758.83.BJR-2018-0193.R1.