Bashar Issa

Dr. Bashar Issa

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
BIBashar Issa
Bashar Issa
IOIhab Obaidat
Ihab Obaidat
BABorhan Albiss
Borhan Albiss
Yousef HaikYousef Haik
Yousef Haik
Due to finite size effects, such as the high surface-to-volume ratio and different crystal structures, magnetic nanoparticles are found to exhibit interesting and considerably different magnetic properties than those found in their corresponding bulk materials. These nanoparticles can be synthesized in several ways (e.g., chemical and physical) with controllable sizes enabling their comparison to biological organisms from cells (10–100 μm), viruses, genes, down to proteins (3–50 nm). The optimization of the nanoparticles’ size, size distribution, agglomeration, coating, and shapes along with their unique magnetic properties prompted the application of nanoparticles of this type in diverse fields. Biomedicine is one of these fields where intensive research is currently being conducted. In this review, we will discuss the magnetic properties of nanoparticles which are directly related to their applications in biomedicine. We will focus mainly on surface effects and ferrite nanoparticles, and on one diagnostic application of magnetic nanoparticles as magnetic resonance imaging contrast agents.

9 January 2015 in Nanomaterials
Verified
Journal Article
Open access
PDF file
IOIhab Obaidat
Ihab Obaidat
BIBashar Issa
Bashar Issa
Yousef HaikYousef Haik
Yousef Haik
Localized magnetic hyperthermia using magnetic nanoparticles (MNPs) under the application of small magnetic fields is a promising tool for treating small or deep-seated tumors. For this method to be applicable, the amount of MNPs used should be minimized. Hence, it is essential to enhance the power dissipation or heating efficiency of MNPs. Several factors influence the heating efficiency of MNPs, such as the amplitude and frequency of the applied magnetic field and the structural and magnetic properties of MNPs. We discuss some of the physics principles for effective heating of MNPs focusing on the role of surface anisotropy, interface exchange anisotropy and dipolar interactions. Basic magnetic properties of MNPs such as their superparamagnetic behavior, are briefly reviewed. The influence of temperature on anisotropy and magnetization of MNPs is discussed. Recent development in self-regulated hyperthermia is briefly discussed. Some physical and practical limitations of using MNPs in magnetic hyperthermia are also briefly discussed.

23 July 2002 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
BIBashar Issa
Bashar Issa
Purpose: To measure for the first time the apparent diffusion coefficient (ADC) values in anatomical regions of the prostate for normal and patient groups, and to investigate its use as a differentiating parameter between healthy and malignant tissue within the patient group.Materials and Methods: Single‐shot diffusion‐weighted echo‐planar imaging (DW‐EPI) was used to measure the ADC in the prostate in normal (N = 7) and patient (N = 19) groups. The spin‐echo images comprised 96 × 96 pixels (field of view of 16 cm, TR/TE = 4000/120 msec) with six b‐factor values ranging from 64 to 786 seconds/mm2.Results: The ADC values averaged over all patients in non‐cancerous and malignant peripheral zone (PZ) tissues were 1.82 ± 0.53 × 10−3 (mean ± SD) and 1.38 ± 0.52 × 10−3 mm2/second, respectively (P = 0.00045, N = 17, paired t‐test). The ADC values were found to be higher in the non‐cancerous PZ (1.88 ± 0.48 × 10−3) than in healthy or benign prostatic hyperplasia central gland (BPH‐CG) region (1.62 ± 0.41 × 10−3). For the normal group, the mean values were 1.91 ± 0.46 × 10−3 and 1.63 ± 0.30 × 10−3 mm2/second for the PZ and CG, respectively (P = 0.011, N = 7). Significant overlap exists between individual values among all tissue types. Furthermore, ADC values for the same tissue type showed no statistically significant difference between the two subject groups.Conclusion: ADC is quantified in the prostate using DW‐EPI. Values are lower in cancerous than in healthy PZ in patients, and in BPH‐CG than PZ in volunteers. J. Magn. Reson. Imaging 2002;16:196–200.

1 September 1998 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
PGPenny A. Gowland
Penny A. Gowland
SFSusan Francis
Susan Francis
KDKeith R. Duncan
Keith R. Duncan
AFAlan J. Freeman
Alan J. Freeman
BIBashar Issa
Bashar Issa
BWBrian S. Worthington
Brian S. Worthington

20 March 2025 in Materials Horizons
Verified
Journal Article
Closed access
PDF file
CGChandu Venkata Veera Muralee Gopi
Chandu Venkata Veera Muralee Gopi
SASalem Alzahmi
Salem Alzahmi
VNVenkatesha Narayanaswamy
Venkatesha Narayanaswamy
KRK. V. G. Raghavendra
K. V. G. Raghavendra
BIBashar Issa
Bashar Issa
IOIhab Obaidat
Ihab Obaidat
Supercapacitors boost wearable/implantable devices with high power & long life. Novel materials aim for better energy density & miniaturization, powering bioelectronics & medical implants with reliable, safe energy.

1 April 1998 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PGP.A Gowland
P.A Gowland
AFA Freeman
A Freeman
BIBashar Issa
Bashar Issa
PBP Boulby
P Boulby
KDK.R Duncan
K.R Duncan
BWB.S Worthington
B.S Worthington