Günther Grabner

Günther Grabner

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2006
Verified
Book Chapter
Closed access
PDF file
GGGünther Grabner
Günther Grabner
AJAndrew L. Janke
Andrew L. Janke
MBMarc M. Budge
Marc M. Budge
DSDavid Smith
David Smith
JPJens Pruessner
Jens Pruessner
DCD. Louis Collins
D. Louis Collins

27 October 2016 in Acta Neuropathologica
Verified
Journal Article
Open access
PDF file
ADAssunta Dal-Bianco
Assunta Dal-Bianco
GGGünther Grabner
Günther Grabner
CKClaudia Kronnerwetter
Claudia Kronnerwetter
MWMichael Weber
Michael Weber
RHRomana Höftberger
Romana Höftberger
SHSimon Hametner
Simon Hametner
In multiple sclerosis (MS), iron accumulates inside activated microglia/macrophages at edges of some chronic demyelinated lesions, forming rims. In susceptibility-based magnetic resonance imaging at 7 T, iron-laden microglia/macrophages induce a rim of decreased signal at lesion edges and have been associated with slowly expanding lesions. We aimed to determine (1) what lesion types and stages are associated with iron accumulation at their edges, (2) what cells at the lesion edges accumulate iron and what is their activation status, (3) how reliably can iron accumulation at the lesion edge be detected by 7 T magnetic resonance imaging (MRI), and (4) if lesions with rims enlarge over time in vivo, when compared to lesions without rims. Double-hemispheric brain sections of 28 MS cases were stained for iron, myelin, and microglia/macrophages. Prior to histology, 4 of these 28 cases were imaged at 7 T using post-mortem susceptibility-weighted imaging. In vivo, seven MS patients underwent annual neurological examinations and 7 T MRI for 3.5 years, using a fluid attenuated inversion recovery/susceptibility-weighted imaging fusion sequence. Pathologically, we found iron rims around slowly expanding and some inactive lesions but hardly around remyelinated shadow plaques. Iron in rims was mainly present in microglia/macrophages with a pro-inflammatory activation status, but only very rarely in astrocytes. Histological validation of post-mortem susceptibility-weighted imaging revealed a quantitative threshold of iron-laden microglia when a rim was visible. Slowly expanding lesions significantly exceeded this threshold, when compared with inactive lesions (p = 0.003). We show for the first time that rim lesions significantly expanded in vivo after 3.5 years, compared to lesions without rims (p = 0.003). Thus, slow expansion of MS lesions with rims, which reflects chronic lesion activity, may, in the future, become an MRI marker for disease activity in MS.

8 February 2016 in Brain
Verified
Journal Article
Open access
PDF file
LHLukas Haider
Lukas Haider
TZTobias Zrzavy
Tobias Zrzavy
SHSimon Hametner
Simon Hametner
RHRomana Höftberger
Romana Höftberger
FBFrancesca Bagnato
Francesca Bagnato
HLHans Lassmann
Hans Lassmann
Multiple sclerosis is a chronic inflammatory disease with primary demyelination and neurodegeneration in the central nervous system. In our study we analysed demyelination and neurodegeneration in a large series of multiple sclerosis brains and provide a map that displays the frequency of different brain areas to be affected by these processes. Demyelination in the cerebral cortex was related to inflammatory infiltrates in the meninges, which was pronounced in invaginations of the brain surface (sulci) and possibly promoted by low flow of the cerebrospinal fluid in these areas. Focal demyelinated lesions in the white matter occurred at sites with high venous density and additionally accumulated in watershed areas of low arterial blood supply. Two different patterns of neurodegeneration in the cortex were identified: oxidative injury of cortical neurons and retrograde neurodegeneration due to axonal injury in the white matter. While oxidative injury was related to the inflammatory process in the meninges and pronounced in actively demyelinating cortical lesions, retrograde degeneration was mainly related to demyelinated lesions and axonal loss in the white matter. Our data show that accumulation of lesions and neurodegeneration in the multiple sclerosis brain does not affect all brain regions equally and provides the pathological basis for the selection of brain areas for monitoring regional injury and atrophy development in future magnetic resonance imaging studies.

1 November 2009 in Radiology
Verified
Journal Article
Closed access
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
SGStephan Gruber
Stephan Gruber
Katja Pinker-DomenigKatja Pinker-Domenig
Katja Pinker-Domenig
GGGünther Grabner
Günther Grabner
Andreas StadlbauerAndreas Stadlbauer
Andreas Stadlbauer
STSiegfried Trattnig
Siegfried Trattnig
Standardization of b values allows improved interstudy comparisons on the diagnostic accuracy of diffusion-weighted MR breast examinations. PurposeTo compare the diagnostic quality of diffusion-weighted (DW) imaging schemes with regard to apparent diffusion coefficient (ADC) accuracy, ADC precision, and DW imaging contrast-to-noise ratio (CNR) for different types of lesions and breast tissue. Materials and MethodsInstitutional review board approval and written, informed consent were obtained. Fifty-one patients with histopathologic correlation or follow-up performed with a 3.0-T MR imager were included in this study. There were 112 regions of interest drawn in 24 malignant, 17 benign, 20 cystic, and 51 normal tissue regions. ADC maps were calculated for combinations of 10 b values (range, 0–1250 sec/mm2). Differences in ADC among tissue types were evaluated. The CNRs of lesions at DW imaging were compared for all b values. A repeated-measures analysis of variance was used to assess lesion differentiation. ResultsADCs calculated from b values of 50 and 850 sec/mm2 were 0.99 × 10−3 mm2/sec ± 0.18 (standard deviation), 1.47 × 10−3 mm2/sec ± 0.21...

1 October 2018 in NeuroImage
Verified
Journal Article
Closed access
SHSimon Hametner
Simon Hametner
VEVerena Endmayr
Verena Endmayr
ADAndreas Deistung
Andreas Deistung
PPPilar Palmrich
Pilar Palmrich
MPMax Prihoda
Max Prihoda
GGGünther Grabner
Günther Grabner

1 September 2009 in Investigative Radiology
Verified
Journal Article
Closed access
Katja Pinker-DomenigKatja Pinker-Domenig
Katja Pinker-Domenig
GGGünther Grabner
Günther Grabner
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
SGStephan Gruber
Stephan Gruber
PSPavol Szomolanyi
Pavol Szomolanyi
THThomas Helbich
Thomas Helbich
To develop a 3.0 Tesla breast imaging protocol that combines high temporal and spatial resolution three-dimensional MR sequences for quantitative time course and morphologic analysis of breast lesions. Thirty-four patients were included in the study (age range, 31–82; mean age, 54.3). The study protocol was approved by the Institutional Review Board and written informed consent was obtained from all patients. The magnetic resonance imaging protocol included: a coronal T1-weighted volume-interpolated-breathhold-examination sequence, focused on high temporal resolution for optimal assessment of the contrast-enhancement behavior of lesions (SI 1.7 mm isotropic; TA 3.45 minutes for 17 measurements); a coronal T1-weighted turbo fast-low-angle-shot-three-dimensional sequence, with water-excitation and fat suppression, focused on high spatial resolution for morphologic analysis (SI 1 mm isotropic; TA 2 minutes); and a repeated coronal volume-interpolated-breathhold-examination sequence for detection of washout. Lesion size and morphology were assessed. Region-of-interests for suspicious areas were manually drawn and evaluated for contrast-enhancement behavior by plotting intensity courses against time. Sensitivity and specificity with a 95% confidence interval and the negative predictive value and positive predictive value were calculated. Diagnostic accuracy was assessed. The histopathological diagnoses were used as a standard of reference. Fifty-five lesions were detected in 34 patients. All malignant breast lesions were identified correctly. There were 5 false-positive lesions. The sensitivity of contrast-enhanced magnetic resonance imaging of the breast at 3 T was 100%, with a 95% confidence interval (CI) of 90.6% to 100%. The specificity was 72.2%, with a 95% CI of 49.1% to 87.5%. The positive predictive value was 0.88 and the negative predictive value was 1. Diagnostic accuracy was 91% with a 95% CI of 80.4% to 96.1%. Our prospective study demonstrates that the presented 3 Tesla MR imaging protocol, comprising both high temporal and high spatial resolution, enables accurate detection and assessment of breast lesions.