ROZALINA ZAKARIA

Dr. ROZALINA ZAKARIA

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Shobhit K. PatelShobhit K. Patel
Shobhit K. Patel
Juveriya ParmarJuveriya Parmar
Juveriya Parmar
RZROZALINA ZAKARIA
ROZALINA ZAKARIA
SASharafali A.
Sharafali A.
TNTruong Nguyen
Truong Nguyen
Vigneswaran DhasarathanVigneswaran Dhasarathan
Vigneswaran Dhasarathan
This work intends for sensitivity analysis of different metasurface array-based biosensors. The array designs in the form of circle array, square array, square circle array, circle square array, five-element square array, plus array, five-element plus square array. The sensitivity of these metasurface biosensors are compared and optimized design is presented. Circle array design shows the best sensitivity performance amongst them. The optimized circle array design is analyzed by varying different physical parameters of the design such as SiO 2 substrate thickness and metasurface array thickness. The optimized results for this variation are also presented. The sensitivity of the current biosensor design is also compared with the previously published similar designs. The results are also presented for electric field intensity and current field density for the optimized design. The proposed sensitive biosensor can become a building block of future biomedical devices and photovoltaic devices.

7 February 2017 in Journal of Modern Optics
Verified
Journal Article
Closed access
RZROZALINA ZAKARIA
ROZALINA ZAKARIA
WKWern Kam
Wern Kam
YOY. S. Ong
Y. S. Ong
SYS. F. A. Z. Yusoff
S. F. A. Z. Yusoff
HAHarith Ahmad
Harith Ahmad
Waleed S MohammadWaleed S Mohammad
Waleed S Mohammad
This paper describes simulation and experimental methods for designing a D-shaped surface plasmon resonance (SPR) fibre sensor. The sensor consists of two set-up approaches. Finite element method is used in simulation on the fibre sensor device. Two experimental methods for detecting relative intensity are used by varying the wavelength of the optical signal sources and the thickness of gold layer coated on the D-shaped fibre. In the first method, the sensor device works by detecting the relative intensity of two optical signal sources having different wavelengths. In the second set-up, the relative intensity between two D-shaped fibres coated with different thicknesses of gold is measured when a single signal source is launched at the input. The difference in intensities of the signal outputs is used to estimate the refractive index at the sensing region. A prototype SPR D-shaped fibre sensor has been fabricated and the experimental results show good agreement with simulation.

11 March 2022 in Optical and Quantum Electronics
Verified
Journal Article
Closed access
PDF file
SPShobhit K. Patel
Shobhit K. Patel
NSNilesh Solanki
Nilesh Solanki
SCShreyas Charola
Shreyas Charola
Juveriya ParmarJuveriya Parmar
Juveriya Parmar
RZROZALINA ZAKARIA
ROZALINA ZAKARIA
ARAhmed nabih zaki Rashed
Ahmed nabih zaki Rashed

1 December 2018 in Results in Physics
Verified
Journal Article
Open access
BPBikash Kumar Paul
Bikash Kumar Paul
ERE. Rajesh
E. Rajesh
SASayed Asaduzzaman
Sayed Asaduzzaman
SIShadidul Islam
Shadidul Islam
Kawsar AhmedKawsar Ahmed
Kawsar Ahmed
RZROZALINA ZAKARIA
ROZALINA ZAKARIA

4 October 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NRNurul Syazwani Rohizat
Nurul Syazwani Rohizat
ARAtiena Husna Abdullah Ripain
Atiena Husna Abdullah Ripain
CLChin Seong Lim
Chin Seong Lim
CTChee Leong Tan
Chee Leong Tan
RZROZALINA ZAKARIA
ROZALINA ZAKARIA
Hybrids plasmonic nanoparticles (NPs) and unique 2D graphene significantly enhanced the photoresponse of the photodetectors. The metallic NPs that exhibit localized surface plasmon resonance (LSPR) improves strong light absorption, scattering and localized electromagnetic field by the incident photons depending on the optimum condition of NPs. We report high-performance photodetectors based on reduced graphene oxide (rGO) integrated with monometallic of Au and Ag nanoparticles via a familiar fabrication technique using an electron beam evaporation machine. Under 680 nm illumination of light, our rGO photodetector exhibited the highest performance for Au-rGO with the highest responsivity of 67.46 AW−1 and the highest specific detectivity (2.39 × 1013 Jones). Meanwhile, Ag-rGO achieved the highest responsivity of 17.23 AW−1, specific detectivity (7.17 × 1011 Jones) at 785 nm. The response time are 0.146 µs and 0.135 µs for Au-rGO and Ag-rGO respectively for both wavelengths. The proposed photodetector with combining monometallic and graphene provide a new strategy to construct reliable and next-generation optoelectronic devices at VIS–NIR region.

7 April 2021 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
Shobhit K. PatelShobhit K. Patel
Shobhit K. Patel
Juveriya ParmarJuveriya Parmar
Juveriya Parmar
Vishal SorathiyaVishal Sorathiya
Vishal Sorathiya
RZROZALINA ZAKARIA
ROZALINA ZAKARIA
TNTruong Nguyen
Truong Nguyen
Vigneswaran DhasarathanVigneswaran Dhasarathan
Vigneswaran Dhasarathan
We propose a novel graphene-based metasurface plasmonic biosensor. The gold split-ring resonator is used as a metasurface element in the biosensor. Split Ring Resonator structures are used to localize and increase electromagnetic field incidents. Two types of split-ring resonator based metasurface (Single split-ring resonator and Double split-ring resonator) designs are analyzed to observe its effect on biosensing. The proposed biosensor is used to sense hemoglobin and urine biomolecules for their different concentrations. The design results in the form of absorption, electric field, and magnetic field are presented. The sensitivity for hemoglobin biomolecules and urine biomolecules are calculated from their absorption peak difference and refractive index difference. The sensitivity results are compared with previously published designs. The proposed single split ring resonator metasurface design has the highest sensitivity for hemoglobin-urine concentrations. The proposed biosensor can become a building block for future medical biosensing devices.