This paper investigates the physical processes involved in the water filling and air expelling process of a pipe with multiple air valves under water slow filling condition, and develops a fully coupledwater–air two-phase stratified numerical model for simulating the process. In this model, the Saint-Venant equations and the Vertical Average Navier–Stokes equations (VANS) are respectively applied to describe the water and air in pipe, and the air valve model is introduced into the VANS equations of air as the source term. The finite-volume method and implicit dual time-stepping method (IDTS) with two-order accuracy are simultaneously used to solve this numerical model to realize the full coupling between water and air movement. Then, the model is validated by using the experimental data of the pressure evolution in pipe and the air velocity evolution of air valves, which respectively characterize the water filling and air expelling process. The results show that the model performs well in capturing the physical processes, and a reasonable agreement is obtained between numerical and experimental results. This agreement demonstrates that the proposed model in this paper offers a practical method for simulating water filling and air expelling process in a pipe with multiple air valves under water slow filling condition.
Water distribution pipe systems (WDPSs) are critical for delivering irrigation water in an irrigation district. Ensuring the WDPS operates with good operational performance has become a key focus for irrigation water management. Assessing the operational performance of WDPS from both water delivery capacity and pressure changes is compatible with the system, but such an approach has rare been proposed systematically. This paper establishes an integrated framework to assess the performance of WDPS by combining a performance indicator system with a simulation model. The performance indicator system encompasses Adequacy, Efficiency, Equity, and Pressure Reliability, capturing both water delivery capacity and pressure changes. The simulation model is established for providing required data for calculating the performance indicators. Applied to a case study, the framework demonstrates its applicability. Under the specified conditions of the case study, the overall assessment results of WDPS are Adequacy (0.99), Efficiency (0.993), Equity (0.0484), and Pressure Reliability (0.82). Meanwhile, the assessment results at different outlet nodes of the WDPS indicate that there may be insufficient pressure and excessive water supply at some outlet nodes of the WDPS. Further interpretation of the results indicates that the proposed method has the potential to be beneficial for irrigation water management, as it enables strategic assessment of the future operational performance of water distribution pipe systems (WDPSs) and provides effective management guidance for irrigation district managers.