ZHAOXIN DU

Mr. ZHAOXIN DU


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2026 in Energies
Verified
Journal Article
Open access
PDF file
MYMengting Yang
Mengting Yang
ZDZHAOXIN DU
ZHAOXIN DU
WZWenbin Zhao
Wenbin Zhao
A Controllable Line-Commutated Converter (CLCC) is a novel piece of equipment for enhancing the commutation failure resistance of High-Voltage Direct Current (HVDC) transmission systems. Traditional lumped parameter models ignore the high-frequency coupling effects of internal distributed stray capacitances, resulting in insufficient transient simulation accuracy and restricting refined engineering design. Taking the CLCC in the HVDC transformation project as the research object, this paper analyzes the distribution characteristics of stray parameters in a press-pack Insulated Gate Bipolar Transistor (IGBT) under stacked structures. By integrating distributed stray parameter networks with the nonlinear characteristics of the devices, an improved IGBT equivalent circuit model is established, with key parameters identified based on field-measured data. Furthermore, an LCC-CLCC simulation model is built and used to replace the improved IGBT model to conduct short-circuit fault simulation verification. The results demonstrate that the high-fidelity model accurately reproduces transient waveforms under Alternating Current (AC) voltage disturbance and faithfully reflects the actual operating characteristics of a surge arrester and IGBT, thereby effectively compensating for the idealized errors inherent in traditional models. This modeling methodology provides a robust theoretical and simulation foundation for parameter optimization, valve control system design, and the secure operation of a CLCC.

18 May 2026 in Energies
Verified
Journal Article
Open access
PDF file
TDTingting Deng
Tingting Deng
ZDZHAOXIN DU
ZHAOXIN DU
WZWenbin Zhao
Wenbin Zhao
JZJing Zhang
Jing Zhang
GZGuangqing Zhang
Guangqing Zhang
Conventional high-voltage direct current (HVDC) systems based on line-commutated converters (LCC) are prone to commutation failures and consume excessive reactive power during AC grid faults. The controllable line-commutated converter (CLCC) was developed to solve these problems. To further investigate CLCC’s practical application in the AC system, this paper proposes a fixed AC voltage control strategy for the inverter-side CLCC. A hybrid LCC-CLCC HVDC transmission system model is built in PSCAD. Simulations are performed under three-phase short-circuit faults and wind power fluctuation scenarios. The results show that, unlike traditional LCC, the CLCC under the proposed control can actively increase its firing angle over 160 degrees during disturbances. This action injects dynamic reactive power into the grid and significantly reduces the AC bus voltage drop. Especially in weak grid conditions, CLCC can greatly reduce reactive power consumption through wide-range active adjustment of the firing angle, thereby improving voltage stability.

3 August 2023
Verified
Book Chapter
Closed access
PDF file
YXYang Xingang
Yang Xingang
XXXiong Xuejun
Xiong Xuejun
ZDZHAOXIN DU
ZHAOXIN DU
YZYajun Zhang
Yajun Zhang
WQWang Qiming
Wang Qiming
JFJia Feng
Jia Feng

11 March 2026 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
YZYajun Zhang
Yajun Zhang
WBWei Bao
Wei Bao
YDYishuai Du
Yishuai Du
XYXingang Yang
Xingang Yang
XGXican Guo
Xican Guo
XZXiaotian Zhang
Xiaotian Zhang

12 August 2026 in Energies
Verified
Journal Article
Open access
PDF file
ZDZHAOXIN DU
ZHAOXIN DU
TPTing Pan
Ting Pan
WZWenbin Zhao
Wenbin Zhao
GZGuangqing Zhang
Guangqing Zhang
MYMengting Yang
Mengting Yang
SYSu Yan
Su Yan
In this paper, an optimization method is proposed for the switching of the main and auxiliary branches of a Novel Controllable Commutation Converter (CLCC). Based on the theoretical model of commutation failure, the AC-side ground fault is decomposed into a DC component, harmonic component and overvoltage component, and a multidimensional fault dataset is constructed by combinatorial analysis. Using the Radviz visual multidimensional data analysis method, the correspondence between the control-and-protection thresholds of CLCC main- and auxiliary-branch switching under multi-component conditions is established, and the optimal switching thresholds under different short-circuit conditions of the AC system are determined. Finally, the validity of the method is verified by a field artificial short-circuit test, which provides theoretical basis and technical support for the reasonable determination of field setting.

23 August 2026 in Energies
Verified
Journal Article
Open access
PDF file
YZYajun Zhang
Yajun Zhang
APAiqiang Pan
Aiqiang Pan
ZDZHAOXIN DU
ZHAOXIN DU
LCLong Chen
Long Chen
ZDZhaoyang Du
Zhaoyang Du
ZHZhenxin Huang
Zhenxin Huang
In offshore wind farm micro-siting, maximizing annual power generation across all wind directions often involves a trade-off among different directional conditions, especially when the primary and secondary wind directions account for most wind energy. To address this issue, this paper proposes a turbine layout strategy combining horizontal and vertical staggering. The objective function maximizes the simplified capital efficiency (power generation per unit capital cost) under the primary and secondary wind directions, for which a layout optimization model is constructed and solved using the Tian Ji’s Horse Racing Algorithm (THRO). A case study on an offshore wind farm validates the proposed approach. Results show that, compared with manual empirical layout and the GA-PSO algorithm, the proposed strategy significantly improves the simplified capital efficiency under the primary and secondary wind directions, while also enhancing overall power generation efficiency across all wind directions. This offers a new technical pathway for offshore wind farm micro-siting. Additionally, the THRO algorithm converges within 30 iterations, outperforming conventional optimization algorithms and demonstrating its effectiveness in solving such optimization problems.