Behrouz Ebrahimi

Mr. Behrouz Ebrahimi

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
BEBehrouz Ebrahimi
Behrouz Ebrahimi
DLDavid Le
David Le
MAMansour Abtahi
Mansour Abtahi
ADAlbert K. Dadzie
Albert K. Dadzie
JLJennifer I. Lim
Jennifer I. Lim
Xincheng YaoXincheng Yao
Xincheng Yao
The purpose of this study is to evaluate layer fusion options for deep learning classification of optical coherence tomography (OCT) angiography (OCTA) images. A convolutional neural network (CNN) end-to-end classifier was utilized to classify OCTA images from healthy control subjects and diabetic patients with no retinopathy (NoDR) and non-proliferative diabetic retinopathy (NPDR). For each eye, three en-face OCTA images were acquired from the superficial capillary plexus (SCP), deep capillary plexus (DCP), and choriocapillaris (CC) layers. The performances of the CNN classifier with individual layer inputs and multi-layer fusion architectures, including early-fusion, intermediate-fusion, and late-fusion, were quantitatively compared. For individual layer inputs, the superficial OCTA was observed to have the best performance, with 87.25% accuracy, 78.26% sensitivity, and 90.10% specificity, to differentiate control, NoDR, and NPDR. For multi-layer fusion options, the best option is the intermediate-fusion architecture, which achieved 92.65% accuracy, 87.01% sensitivity, and 94.37% specificity. To interpret the deep learning performance, the Gradient-weighted Class Activation Mapping (Grad-CAM) was utilized to identify spatial characteristics for OCTA classification. Comparative analysis indicates that the layer data fusion options can affect the performance of deep learning classification, and the intermediate-fusion approach is optimal for OCTA classification of DR.

17 April 2023 in Communications Medicine
Verified
Journal Article
Open access
PDF file
MAMansour Abtahi
Mansour Abtahi
DLDavid Le
David Le
BEBehrouz Ebrahimi
Behrouz Ebrahimi
ADAlbert K. Dadzie
Albert K. Dadzie
JLJennifer I. Lim
Jennifer I. Lim
Xincheng YaoXincheng Yao
Xincheng Yao
Background: Differential artery-vein (AV) analysis in optical coherence tomography angiography (OCTA) holds promise for the early detection of eye diseases. However, currently available methods for AV analysis are limited for binary processing of retinal vasculature in OCTA, without quantitative information of vascular perfusion intensity. This study is to develop and validate a method for quantitative AV analysis of vascular perfusion intensity.Method: A deep learning network AVA-Net has been developed for automated AV area (AVA) segmentation in OCTA. Seven new OCTA features, including arterial area (AA), venous area (VA), AVA ratio (AVAR), total perfusion intensity density (T-PID), arterial PID (A-PID), venous PID (V-PID), and arterial-venous PID ratio (AV-PIDR), were extracted and tested for early detection of diabetic retinopathy (DR). Each of these seven features was evaluated for quantitative evaluation of OCTA images from healthy controls, diabetic patients without DR (NoDR), and mild DR.Results: It was observed that the area features, i.e., AA, VA and AVAR, can reveal significant differences between the control and mild DR. Vascular perfusion parameters, including T-PID and A-PID, can differentiate mild DR from control group. AV-PIDR can disclose significant differences among all three groups, i.e., control, NoDR, and mild DR. According to Bonferroni correction, the combination of A-PID and AV-PIDR can reveal significant differences in all three groups.Conclusions: AVA-Net, which is available on GitHub for open access, enables quantitative AV analysis of AV area and vascular perfusion intensity. Comparative analysis revealed AV-PIDR as the most sensitive feature for OCTA detection of early DR. Ensemble AV feature analysis, e.g., the combination of A-PID and AV-PIDR, can further improve the performance for early DR assessment.

9 February 2024 in Communications Engineering
Verified
Journal Article
Open access
PDF file
DLDavid Le
David Le
TSTaeyoon Son
Taeyoon Son
TKTae-Hoon Kim
Tae-Hoon Kim
TATobiloba Adejumo
Tobiloba Adejumo
MAMansour Abtahi
Mansour Abtahi
Xincheng YaoXincheng Yao
Xincheng Yao
Optical coherence tomography angiography (OCTA) provides unrivaled capability for depth-resolved visualization of retinal vasculature at the microcapillary level resolution. For OCTA image construction, repeated OCT scans from one location are required to identify blood vessels with active blood flow. The requirement for multi-scan-volumetric OCT can reduce OCTA imaging speed, which will induce eye movements and limit the image field-of-view. In principle, the blood flow should also affect the reflectance brightness profile along the vessel direction in a single-scan-volumetric OCT. Here we report a spatial vascular connectivity network (SVC-Net) for deep learning OCTA construction from single-scan-volumetric OCT. We quantitatively determine the optimal number of neighboring B-scans as image input, we compare the effects of neighboring B-scans to single B-scan input models, and we explore different loss functions for optimization of SVC-Net. This approach can improve the clinical implementation of OCTA by improving transverse image resolution or increasing the field-of-view.

1 May 2023 in Experimental Biology and Medicine
Verified
Journal Article
Closed access
DLDavid Le
David Le
MAMansour Abtahi
Mansour Abtahi
TATobiloba Adejumo
Tobiloba Adejumo
BEBehrouz Ebrahimi
Behrouz Ebrahimi
ADAlbert K Dadzie
Albert K Dadzie
Xincheng YaoXincheng Yao
Xincheng Yao
Major retinopathies can differentially impact the arteries and veins. Traditional fundus photography provides limited resolution for visualizing retinal vascular details. Optical coherence tomography (OCT) can provide improved resolution for retinal imaging. However, it cannot discern capillary-level structures due to the limited image contrast. As a functional extension of OCT modality, optical coherence tomography angiography (OCTA) is a non-invasive, label-free method for enhanced contrast visualization of retinal vasculatures at the capillary level. Recently differential artery–vein (AV) analysis in OCTA has been demonstrated to improve the sensitivity for staging of retinopathies. Therefore, AV classification is an essential step for disease detection and diagnosis. However, current methods for AV classification in OCTA have employed multiple imagers, that is, fundus photography and OCT, and complex algorithms, thereby making it difficult for clinical deployment. On the contrary, deep learning (DL) algorithms may be able to reduce computational complexity and automate AV classification. In this article, we summarize traditional AV classification methods, recent DL methods for AV classification in OCTA, and discuss methods for interpretability in DL models.

22 May 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
MAMansour Abtahi
Mansour Abtahi
DLDavid Le
David Le
BEBehrouz Ebrahimi
Behrouz Ebrahimi
ADAlbert K. Dadzie
Albert K. Dadzie
MRMojtaba Rahimi
Mojtaba Rahimi
Xincheng YaoXincheng Yao
Xincheng Yao
This study investigates the impact of differential artery-vein (AV) analysis in optical coherence tomography angiography (OCTA) on machine learning classification of diabetic retinopathy (DR). Leveraging deep learning for arterial-venous area (AVA) segmentation, six quantitative features, including perfusion intensity density (PID), blood vessel density (BVD), vessel area flux (VAF), blood vessel caliber (BVC), blood vessel tortuosity (BVT), and vessel perimeter index (VPI) features, were derived from OCTA images before and after AV differentiation. A support vector machine (SVM) classifier was utilized to assess both binary and multiclass classifications of control, diabetic patients without DR (NoDR), mild DR, moderate DR, and severe DR groups. Initially, one-region features, i.e., quantitative features extracted from the entire OCTA, were evaluated for DR classification. Differential AV analysis improved classification accuracies from 78.86% to 87.63% and from 79.62% to 85.66% for binary and multiclass classifications, respectively. Additionally, three-region features derived from the entire image, parafovea, and perifovea, were incorporated for DR classification. Differential AV analysis further enhanced classification accuracies from 84.43% to 93.33% and from 83.40% to 89.25% for binary and multiclass classifications, respectively. These findings highlight the potential of differential AV analysis in augmenting disease diagnosis and treatment assessment using OCTA.

25 September 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
ADAlbert K. Dadzie
Albert K. Dadzie
DLDavid Le
David Le
MAMansour Abtahi
Mansour Abtahi
BEBehrouz Ebrahimi
Behrouz Ebrahimi
TATobiloba Adejumo
Tobiloba Adejumo
Xincheng YaoXincheng Yao
Xincheng Yao
Optical coherence tomography angiography (OCTA) has significantly advanced the study and diagnosis of eye diseases. However, current clinical OCTA systems and software tools lack comprehensive quantitative analysis capabilities, limiting their full clinical utility. This paper introduces the OCTA Retinal Vessel Analyzer (OCTA-ReVA), a versatile open-source platform featuring a user-friendly graphical interface designed for the automated extraction and quantitative analysis of OCTA features. OCTA-ReVA includes traditional established OCTA features based on binary vascular image processing, such as blood vessel density (BVD), foveal avascular zone area (FAZ-A), blood vessel tortuosity (BVT), and blood vessel caliber (BVC). Additionally, it introduces new features based on blood perfusion intensity processing, such as perfusion intensity density (PID), vessel area flux (VAF), and normalized blood flow index (NBFI), which provide deeper insights into retinal perfusion conditions. These additional capabilities are crucial for the early detection and monitoring of retinal diseases. OCTA-ReVA demystifies the intricate task of retinal vasculature quantification, offering a robust tool for researchers and clinicians to objectively evaluate eye diseases and enhance the precision of retinal health assessments.