Mojtaba Rahimi

Dr. Mojtaba Rahimi

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
ARalfa rossi
alfa rossi
MRMojtaba Rahimi
Mojtaba Rahimi
DLDavid Le
David Le
TSTaeyoon Son
Taeyoon Son
MHMichael J. Heiferman
Michael J. Heiferman
Xincheng YaoXincheng Yao
Xincheng Yao
Fundus photography is indispensable for the clinical detection and management of eye diseases. Low image contrast and small field of view (FOV) are common limitations of conventional fundus photography, making it difficult to detect subtle abnormalities at the early stages of eye diseases. Further improvements in image contrast and FOV coverage are important for early disease detection and reliable treatment assessment. We report here a portable, wide FOV fundus camera with high dynamic range (HDR) imaging capability. Miniaturized indirect ophthalmoscopy illumination was employed to achieve the portable design for nonmydriatic, widefield fundus photography. Orthogonal polarization control was used to eliminate illumination reflectance artifacts. With independent power controls, three fundus images were sequentially acquired and fused to achieve HDR function for local image contrast enhancement. A 101° eye-angle (67° visual-angle) snapshot FOV was achieved for nonmydriatic fundus photography. The effective FOV was readily expanded up to 190° eye-angle (134° visual-angle) with the aid of a fixation target without the need for pharmacologic pupillary dilation. The effectiveness of HDR imaging was validated with both normal healthy and pathologic eyes, compared to a conventional fundus camera.

27 June 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MRMojtaba Rahimi
Mojtaba Rahimi
MMMohammad Malekmohammad
Mohammad Malekmohammad
MTMajid Taghavi
Majid Taghavi
MNMohammad Noori
Mohammad Noori
GPGholam-Mohammad Mohammad Parsanasab
Gholam-Mohammad Mohammad Parsanasab
In this paper, a differential micro-opto-electro-mechanical system (MOEMS) accelerometer based on the Fabry-Pérot (FP) micro-cavities is presented. The optical system of the device consists of two FP cavities and the mechanical system is composed of a proof mass that is suspended by four springs. The applied acceleration tends to move the PM from its resting position. This mechanical displacement can be measured by the FP interferometer formed between the proof mass cross-section and the optical fiber end-face. The proposed sensor is fabricated on a silicon-on-insulator wafer using the bulk micromachining method. The results of the sensor characterization show that the accelerometer has a linear response in the range of $\boldsymbol {\pm }1\text{g}$ . Also, the optical sensitivity and resolution of the sensor in the static characterization are 6.52 nm/g and $153 \boldsymbol {\mu }\text{g}$ . The sensor sensitivity in the power measurement is 49.6 mV/g and its resonant frequency is at 1372 Hz. Using the differential measurement method increases the sensitivity of the accelerometer. Based on the experimental data, the optical sensitivity in static mode is two times as high as that of a similar MOEMS accelerometer with one FP cavity.

23 May 2022 in Optics Express
Verified
Journal Article
Closed access
MTMajid Taghavi
Majid Taghavi
AAAbolfazl Abedi
Abolfazl Abedi
GPGholam-Mohammad Parsanasab
Gholam-Mohammad Parsanasab
MRMojtaba Rahimi
Mojtaba Rahimi
MNMohammad Noori
Mohammad Noori
HLHamid Latifi
Hamid Latifi
In this paper, a closed-loop micro-opto-electro-mechanical system (MOEMS) accelerometer based on the Fabry-Pérot (FP) interferometer is presented. The FP cavity is formed between the end of a cleaved single-mode optical fiber and the cross-section of a proof mass (PM) which is suspended by four U-shaped springs. The applied acceleration tends to move the PM in the opposite direction. The arrays of fixed and movable comb fingers produce an electrostatic force which keeps the PM in its resting position. The voltage that can provide this electrostatic force is considered as the output of the sensor. Using a closed-loop detection method it is possible to increase the measurement range without losing the resolution. The proposed sensor is fabricated on a silicon-on-insulator wafer using the bulk micromachining method. The results of the sensor characterization show that the accelerometer has a linear response in the range of ±5 g. In the closed-loop mode, the sensitivity and bias instability of the sensor are 1.16 V/g and 40 µg, respectively.

6 October 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
MRMojtaba Rahimi
Mojtaba Rahimi
ARalfa rossi
alfa rossi
TSTaeyoon Son
Taeyoon Son
DTDevrim Toslak
Devrim Toslak
DLDavid Le
David Le
Xincheng YaoXincheng Yao
Xincheng Yao
Multi-spectral widefield fundus photography is valuable for the clinical diagnosis and management of ocular conditions that may impact both central and peripheral regions of the retina and choroid. Trans-palpebral illumination has been demonstrated as an alternative to transpupillary illumination for widefield fundus photography without requiring pupil dilation. However, spectral efficiency can be complicated due to the spatial variance of the light property through the palpebra and sclera. This study aims to investigate the effect of light delivery location on spectral efficiency in trans-palpebral illumination. Four narrow-band light sources, covering both visible and near infrared (NIR) wavelengths, were used to evaluate spatial dependency of spectral illumination efficiency. Comparative analysis indicated a significant dependence of visible light efficiency on spatial location, while NIR light efficiency is only slightly affected by the illumination location. This study confirmed the pars plana as the optimal location for delivering visible light to achieve color imaging of the retina. Conversely, spatial location is not critical for NIR light imaging of the choroid.

22 May 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
MAMansour Abtahi
Mansour Abtahi
DLDavid Le
David Le
BEBehrouz Ebrahimi
Behrouz Ebrahimi
ADAlbert K. Dadzie
Albert K. Dadzie
MRMojtaba Rahimi
Mojtaba Rahimi
Xincheng YaoXincheng Yao
Xincheng Yao
This study investigates the impact of differential artery-vein (AV) analysis in optical coherence tomography angiography (OCTA) on machine learning classification of diabetic retinopathy (DR). Leveraging deep learning for arterial-venous area (AVA) segmentation, six quantitative features, including perfusion intensity density (PID), blood vessel density (BVD), vessel area flux (VAF), blood vessel caliber (BVC), blood vessel tortuosity (BVT), and vessel perimeter index (VPI) features, were derived from OCTA images before and after AV differentiation. A support vector machine (SVM) classifier was utilized to assess both binary and multiclass classifications of control, diabetic patients without DR (NoDR), mild DR, moderate DR, and severe DR groups. Initially, one-region features, i.e., quantitative features extracted from the entire OCTA, were evaluated for DR classification. Differential AV analysis improved classification accuracies from 78.86% to 87.63% and from 79.62% to 85.66% for binary and multiclass classifications, respectively. Additionally, three-region features derived from the entire image, parafovea, and perifovea, were incorporated for DR classification. Differential AV analysis further enhanced classification accuracies from 84.43% to 93.33% and from 83.40% to 89.25% for binary and multiclass classifications, respectively. These findings highlight the potential of differential AV analysis in augmenting disease diagnosis and treatment assessment using OCTA.

24 October 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
ARalfa rossi
alfa rossi
MRMojtaba Rahimi
Mojtaba Rahimi
TSTaeyoon Son
Taeyoon Son
RCR. V. Paul Chan
R. V. Paul Chan
MHMichael J. Heiferman
Michael J. Heiferman
Xincheng YaoXincheng Yao
Xincheng Yao
The purpose of this study is to demonstrate the feasibility of using polarization maintaining photons for enhanced contrast imaging of the retina. Orthogonal-polarization control has been frequently used in conventional fundus imaging systems to minimize reflection artifacts. However, the orthogonal-polarization configuration also rejects the directly reflected photons, which preserve the polarization condition of incident light, from the superficial layer of the fundus, i.e., the retina, and thus reduce the contrast of retinal imaging. We report here a portable fundus camera which can simultaneously perform orthogonal-polarization control to reject back-reflected light from the ophthalmic lens and parallel-polarization control to preserve the backscattered light from the retina which partially maintains the polarization state of the incoming light. This portable device utilizes miniaturized indirect ophthalmoscopy illumination to achieve non-mydriatic imaging, with a snapshot field of view of 101° eye-angle (67° visual-angle). Comparative analysis of retinal images acquired with a traditional orthogonal-polarization fundus camera from both normal and diseased eyes was conducted to validate the usefulness of the proposed design. The parallel-polarization control for enhanced contrast in high dynamic range imaging has also been validated.