Kanchana Silawarawet

Dr. Kanchana Silawarawet

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2026 in Sensors
Verified
Journal Article
Open access
PDF file
KSKanchana Silawarawet
Kanchana Silawarawet
CTChutipon Trirattananurak
Chutipon Trirattananurak
JMJirawat Muksuwan
Jirawat Muksuwan
SSSurasak Sangdao
Surasak Sangdao
DPDarawadee Panich
Darawadee Panich
SSSairag Sa-adprai
Sairag Sa-adprai
Global warming and increasing heatwaves elevate the risk of exertional heat illnesses, particularly heatstroke, in endurance athletes and outdoor workers. This study developed and validated a wearable heatstroke warning system integrating physiological and environmental monitoring with a real-time web dashboard. The wrist- and finger-worn prototype comprised an ESP32 microcontroller and heart rate (MAX30101), skin temperature (MAX30205), ambient temperature and humidity (SHT31), and galvanic skin response (Grove-GSR v1.2) sensors with dual acoustic–visual alerts and WiFi transmission. Fifteen triathletes (18–39 years) completed 30 min of cycling in a climatic chamber: 0–15 min at 24 ± 1 °C, 70 ± 10% RH, and 16–30 min at 27 ± 1 °C, 90 ± 10% RH, with the workload rising from 40%HRmax by 10% every 10 min. Heart rate, estimated core temperature, ambient temperature, relative humidity, and GSR were recorded every 30 s and compared with standard devices using Spearman correlation (p = 0.01) and Wilcoxon signed-rank tests (p < 0.05). Heart rate, skin temperature (used a linear model to calculate core body temperature), ambient temperature, and humidity sensors showed fair–very good validity (r = 0.692, 0.995, 0.994, 0.952), while GSR was low (r = 0.298). No significant differences were observed for heart rate, skin temperature, and humidity (p > 0.05), but body temperature (p = 0.003) and GSR (p < 0.001) differed. The system showed promising validity for real-time heatstroke risk monitoring, with further refinement needed for skin temperature and GSR sensing.

7 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
KSKanchana Silawarawet
Kanchana Silawarawet
PKPhattarakorn Kaewchukul
Phattarakorn Kaewchukul
SSSairag Sa-adprai
Sairag Sa-adprai
This research has developed a heat stroke warning system prototype for athletes utilizing the following sensors: DHT22, GY-906-BAA MLX90614, MAX30102. The device calculates the heat stroke risk and notifies users. The data is recorded, stored, displayed on a free-access website which graphs body temperature, ambient temperature, humidity, heart rate and heat stroke risk, and provides notifications for athletes engaged in outdoor activities. The researchers recorded sensors data (n = 1) for two sessions (12 min/session) in a closed room, at the sixth-minute marker, with an air conditioner activated to observe the changes observed by the sensors. For accuracy, the researchers employed Criterion-Related Validity, comparing sensor against standard equipment measurement. For reliability, we utilized Test-Retest Reliability, comparing sensor data from the first and second measurements. Accuracy and reliability were evaluated using the Pearson Correlation Coefficient, with significance set at p < 0.01. The DHT22 sensor demonstrates very high accuracy (r = 0.923) in ambient temperature and (r = 0.774) humidity measurements. It showed no significant reliability (r = 0.489) in temperature and (r = 0.185) humidity measurements. The GY-906-BAA MLX90614 sensor exhibited very high accuracy (r = 0.923) and reliability (r = 0.866) in body temperature measurements. The MAX30102 sensor lacked significant accuracy (r = 0.179) and reliability (r = 0.171) in heart rate measurements. The development of accuracy and reliability of sensors are important for preventing heat stroke in future applications.